38 research outputs found

    Atmospheric N2O and CH4 total columns retrieved from low-resolution Fourier transform infrared (FTIR) spectra (Bruker VERTEX 70) in the mid-infrared region

    Get PDF
    Nitrous oxide (N2O) and methane (CH4) are two important greenhouse gases in the atmosphere. In 2019, mid-infrared (MIR) solar absorption spectra were recorded by a Bruker VERTEX 70 spectrometer and a Bruker IFS 125HR spectrometer at Sodankylä, Finland, at spectral resolutions of 0.2 and 0.005 cm−1, respectively. The N2O and the CH4 retrievals from high-resolution MIR spectra have been well investigated within the Network for the Detection of Atmospheric Composition Change (NDACC) but not for MIR spectra gathered with instruments operating at low spectral resolution. In this study, N2O and CH4 retrieval strategies and retrieval uncertainties from the VERTEX 70 MIR low-resolution spectra are discussed and presented. The accuracy and precision of the VERTEX 70 N2O and CH4 retrievals are assessed by comparing them with the coincident 125HR retrievals and AirCore measurements. The relative differences between the N2O total columns retrieved from 125HR and VERTEX 70 spectra are −0.3 ± 0.7 (1σ) % with a correlation coefficient (R) of 0.93. Regarding the CH4 total column, we first used the same retrieval microwindows for 125HR and VERTEX 70 spectra, but there is an underestimation in the VERTEX 70 retrievals, especially in summer. The relative differences between the CH4 total columns retrieved from the 125HR and VERTEX 70 spectra are -1.3±1.1 (1σ) % with a R value of 0.77. To improve the VERTEX 70 CH4 retrievals, we propose alternative retrieval microwindows. The relative differences between the CH4 total columns retrieved from the 125HR and VERTEX 70 spectra in these new windows become 0.0±0.8 (1σ) %, along with an increase in the R value to 0.87. The coincident AirCore measurements confirm that the VERTEX 70 CH4 retrievals using the latter window choice are better, with relative mean differences between the VERTEX 70 CH4 retrievals and AirCore measurements of −1.9 % for the standard NDACC microwindows and of 0.13 % for the alternative microwindows. This study provides insight into the N2O and CH4 retrievals from the low-resolution (0.2 cm−1) MIR spectra observed with a VERTEX 70 spectrometer, and it demonstrates the suitability of this kind of instrument for contributing to satellite validation, model verification, and other scientific campaigns with the advantage of its transportability and lower cost compared to standard NDACC-type Fourier-transform infrared (FTIR) instruments.</p

    Retrieval of atmospheric CH_4 vertical information from ground-based FTS near-infrared spectra

    Get PDF
    International audienceThe Total Carbon Column Observing Network (TCCON) column-averaged dry air mole fraction of CH 4 (X CH 4) measurements have been widely used to validate satellite observations and to estimate model simulations. The GGG2014 code is the standard TCCON retrieval software used in performing a profile scaling retrieval. In order to obtain several vertical pieces of information in addition to the total column, in this study, the SFIT4 retrieval code is applied to retrieve the CH 4 mole fraction vertical profile from the Fourier transform spectrometer (FTS) spectrum at six sites (Ny-Ålesund, Sodankylä, Bialystok, Bremen, Orléans and St Denis) during the time period of 2016-2017. The retrieval strategy of the CH 4 profile retrieval from ground-based FTS near-infrared (NIR) spectra using the SFIT4 code (SFIT4NIR) is investigated. The degree of freedom for signal (DOFS) of the SFIT4NIR retrieval is about 2.4, with two distinct pieces of information in the troposphere and in the stratosphere. The averaging kernel and error budget of the SFIT4NIR retrieval are presented. The data accuracy and precision of the SFIT4NIR retrievals, including the total column and two partial columns (in the troposphere and stratosphere), are estimated by TCCON standard retrievals, ground-based in situ measurements, Atmospheric Chemistry Experiment-Fourier Transform Spectrometer (ACE-FTS) satellite observations, TCCON proxy data and AirCore and aircraft measurements. By comparison against TCCON standard retrievals, it is found that the retrieval uncertainty of SFIT4NIR X CH 4 is similar to that of TCCON standard retrievals with systematic uncertainty within 0.35 % and random uncertainty of about 0.5 %. The tropospheric and strato-spheric X CH 4 from SFIT4NIR retrievals are assessed by comparison with AirCore and aircraft measurements, and there is a 1.0 ± 0.3 % overestimation in the SFIT4NIR tropospheric X CH 4 and a 4.0 ± 2.0 % underestimation in the SFIT4NIR stratospheric X CH 4 , which are within the systematic uncertainties of SFIT4NIR-retrieved partial columns in the tropo-sphere and stratosphere respectively

    Nitrous Oxide Profiling from Infrared Radiances (NOPIR): Algorithm Description, Application to 10 Years of IASI Observations and Quality Assessment

    Get PDF
    Nitrous oxide (N2_{2}O) is the third most abundant anthropogenous greenhouse gas (after carbon dioxide and methane), with a long atmospheric lifetime and a continuously increasing concentration due to human activities, making it an important gas to monitor. In this work, we present a new method to retrieve N2_{2}O concentration profiles (with up to two degrees of freedom) from each cloud-free satellite observation by the Infrared Atmospheric Sounding Interferometer (IASI), using spectral micro-windows in the N2_{2}O ν3_{3} band, the Radiative Transfer for TOVS (RTTOV) tools and the Tikhonov regularization scheme. A time series of ten years (2011–2020) of IASI N2_{2}O profiles and integrated partial columns has been produced and validated with collocated ground-based Network for the Detection of Atmospheric Composition Change (NDACC) and Total Carbon Column Observing Network (TCCON) data. The importance of consistency in the ancillary data used for the retrieval for generating consistent time series has been demonstrated. The Nitrous Oxide Profiling from Infrared Radiances (NOPIR) N2_{2}O partial columns are of very good quality, with a positive bias of 1.8 to 4% with respect to the ground-based data, which is less than the sum of uncertainties of the compared values. At high latitudes, the comparisons are a bit worse, due to either a known bias in the ground-based data, or to a higher uncertainty in both ground-based and satellite retrievals

    Validation of methane and carbon monoxide from Sentinel-5 Precursor using TCCON and NDACC-IRWG stations

    Get PDF
    The Sentinel-5 Precursor (S5P) mission with the TROPOspheric Monitoring Instrument (TROPOMI) on board has been measuring solar radiation backscattered by the Earth\u27s atmosphere and surface since its launch on 13 October 2017. In this paper, we present for the first time the S5P operational methane (CH4) and carbon monoxide (CO) products\u27 validation results covering a period of about 3 years using global Total Carbon Column Observing Network (TCCON) and Infrared Working Group of the Network for the Detection of Atmospheric Composition Change (NDACC-IRWG) network data, accounting for a priori alignment and smoothing uncertainties in the validation, and testing the sensitivity of validation results towards the application of advanced co-location criteria. We found that the S5P standard and bias-corrected CH4 data over land surface for the recommended quality filtering fulfil the mission requirements. The systematic difference of the bias-corrected total column-averaged dry air mole fraction of methane (XCH4) data with respect to TCCON data is −0.26±0.56 % in comparison to −0.68±0.74 % for the standard XCH4 data, with a correlation of 0.6 for most stations. The bias shows a seasonal dependence. We found that the S5P CO data over all surfaces for the recommended quality filtering generally fulfil the missions requirements, with a few exceptions, which are mostly due to co-location mismatches and limited availability of data. The systematic difference between the S5P total column-averaged dry air mole fraction of carbon monoxide (XCO) and the TCCON data is on average 9.22±3.45 % (standard TCCON XCO) and 2.45±3.38 % (unscaled TCCON XCO). We found that the systematic difference between the S5P CO column and NDACC CO column (excluding two outlier stations) is on average 6.5±3.54 %. We found a correlation of above 0.9 for most TCCON and NDACC stations. The study shows the high quality of S5P CH4 and CO data by validating the products against reference global TCCON and NDACC stations covering a wide range of latitudinal bands, atmospheric conditions and surface conditions

    Création d'un espace conceptuel par analyse de données contextuelles

    No full text
    info:eu-repo/semantics/publishe

    Vertical Profiling of Volcanic Ash from the 2011 Puyehue Cordón Caulle Eruption Using IASI

    Get PDF
    Volcanic ash is emitted by most eruptions, sometimes reaching the stratosphere. In addition to its climate effect, ash may have a significant impact on civilian flights. Currently, the horizontal distribution of ash aerosols is quite extensively studied, but not its vertical profile, while of high importance for both applications mentioned. Here, we study the sensitivity of the thermal infrared spectral range to the altitude distribution of volcanic ash, based on similar work that was undertaken on mineral dust. We use measurements by the Infrared Atmospheric Sounding Interferometer (IASI) instruments onboard the MetOp satellite series. The retrieval method that we develop for the ash vertical profile is based on the optimal estimation formalism. This method is applied to study the eruption of the Chilean volcano Puyehue, which started on the 4th of June 2011. The retrieved profiles agree reasonably well with Cloud-Aerosol LiDAR with Orthogonal Polarization (CALIOP) measurements, and our results generally agree with literature studies of the same eruption. The retrieval strategy presented here therefore is very promising for improving our knowledge of the vertical distribution of volcanic ash and obtaining a global 3D ash distribution twice a day. Future improvements of our retrieval strategy are also discussed

    TCCON data from Xianghe, China, Release GGG2020.R0

    No full text
    The Total Carbon Column Observing Network (TCCON) is a network of ground-based Fourier Transform Spectrometers that record direct solar absorption spectra of the atmosphere in the near-infrared. From these spectra, accurate and precise column-averaged abundances of atmospheric constituents including CO2, CH4, N2O, HF, CO, H2O, and HDO, are retrieved. This is the GGG2020 data release of observations from the TCCON station at Xianghe, ChinaContact person: Zhou, Minqiang [email protected] available via S3 at https://renc.osn.xsede.org/ini210004tommorrell/10.14291/tccon.ggg2020.xianghe01.R0/&lt;/p&gt;README.txt 0.0 GB &lt;a role="button" class="ui compact mini button" href="https://renc.osn.xsede.org/ini210004tommorrell/10.14291/tccon.ggg2020.xianghe01.R0/README.txt" &gt; &lt;i class="download icon"&gt;&lt;/i&gt; Download &lt;/a&gt;&lt;/p&gt; xh20180614_20211130.public.qc.nc 0.02 GB &lt;a role="button" class="ui compact mini button" href="https://renc.osn.xsede.org/ini210004tommorrell/10.14291/tccon.ggg2020.xianghe01.R0/xh20180614_20211130.public.qc.nc" &gt; &lt;i class="download icon"&gt;&lt;/i&gt; Download &lt;/a&gt;&lt;/p&gt; LICENSE.txt 0.0 GB &lt;a role="button" class="ui compact mini button" href="https://renc.osn.xsede.org/ini210004tommorrell/10.14291/tccon.ggg2020.xianghe01.R0/LICENSE.txt" &gt; &lt;i class="download icon"&gt;&lt;/i&gt; Download &lt;/a&gt;&lt;/p&gt
    corecore