9 research outputs found

    Impact of treatment planning and delivery factors on gastrointestinal toxicity: an analysis of data from the RADAR prostate radiotherapy trial

    Get PDF
    Background: To assess the impact of incremental modifications of treatment planning and delivery technique, as well as patient anatomical factors, on late gastrointestinal toxicity using data from the TROG 03.04 RADAR prostate radiotherapy trial. Methods: The RADAR trial accrued 813 external beam radiotherapy participants during 2003–2008 from 23 centres. Following review and archive to a query-able database, digital treatment plans and data describing treatment technique for 754 patients were available for analysis. Treatment demographics, together with anatomical features, were assessed using uni- and multivariate regression models against late gastrointestinal toxicity at 18-, 36- and 54-month follow-up. Regression analyses were reviewed in the context of dose-volume data for the rectum and anal canal. Results: A multivariate analysis at 36-month follow-up shows that patients planned using a more rigorous dose calculation algorithm (DCA) was associated with a lower risk of stool frequency (OR: 0.435, CI: 0.242–0.783, corrected p = 0.04). Patients using laxative as a method of bowel preparation had higher risk of having increased stool frequency compared to patients with no dietary intervention (OR: 3.639, CI: 1.502 8.818, corrected p = 0.04). Despite higher risks of toxicities, the anorectum, anal canal and rectum dose-volume histograms (DVH) indicate patients using laxative had unremarkably different planned dose distributions. Patients planned with a more rigorous DCA had lower median DVH values between EQD2₃ = 15 Gy and EQD2₃ = 35 Gy. Planning target volume (PTV), conformity index, rectal width and prescription dose were not significant when adjusted for false discovery rate. Number of beams, beam energy, treatment beam definition, positioning orientation, rectum-PTV separation, rectal length and mean cross sectional area did not affect the risk of toxicities. Conclusions: The RADAR study dataset has allowed an assessment of technical modifications on gastrointestinal toxicity. A number of interesting associations were subsequently found and some factors, previously hypothesised to influence toxicity, did not demonstrate any significant impact. We recommend trial registries be encouraged to record technical modifications introduced during the trial in order for more powerful evidence to be gathered regarding the impact of the interventions

    Multi-observer contouring of male pelvic anatomy: Highly variable agreement across conventional and emerging structures of interest

    No full text
    Introduction: This study quantified inter‐observer contouring variations for multiple male pelvic structures, many of which are of emerging relevance for prostate cancer radiotherapy progression and toxicity response studies. Methods: Five prostate cancer patient datasets (CT and T2‐weighted MR) were distributed to 13 observers for contouring. CT structures contoured included the clinical target volume (CTV), seminal vesicles, rectum, colon, bowel bag, bladder and peri‐rectal space (PRS). MR contours included CTV, trigone, membranous urethra, penile bulb, neurovascular bundle and multiple pelvic floor muscles. Contouring variations were assessed using the intraclass correlation coefficient (ICC), Dice similarity coefficient (DSC), and multiple additional metrics. Results: Clinical target volume (CT and MR), bladder, rectum and PRS contours showed excellent inter‐observer agreement (median ICC = 0.97; 0.99; 1.00; 0.95; 0.90, DSC = 0.83 ± 0.05; 0.88 ± 0.05; 0.93 ± 0.03; 0.81 ± 0.07; 0.80 ± 0.06, respectively). Seminal vesicle contours were more variable (ICC = 0.75, DSC = 0.73 ± 0.14), while colon and bowel bag contoured volumes were consistent (ICC = 0.97; 0.97), but displayed poor overlap (DSC = 0.58 ± 0.22; 0.67 ± 0.21). Smaller MR structures showed significant inter‐observer variations, with poor overlap for trigone, membranous urethra, penile bulb, and left and right neurovascular bundles (DSC = 0.44 ± 0.22; 0.41 ± 0.21; 0.66 ± 0.21; 0.16 ± 0.17; 0.15 ± 0.15). Pelvic floor muscles recorded moderate to strong inter‐observer agreement (ICC = 0.50–0.97), although large outlier variations were observed. Conclusions: Inter‐observer contouring variation was significant for multiple pelvic structures contoured on MR

    An assessment of radiation oncology medical physicists’ perspectives on undertaking research

    No full text
    As part of a study of the radiation oncology workforce, radiation oncology medical physicists (ROMPs) who had worked in Australia were surveyed regarding their attitudes to participating in research. Responses from 88 ROMPs were available for analysis, representing a broad mix of employment situations and research experience. Greater than 70% of ROMPs described their involvement in research as “liking it” or “loving it”, with associated identified benefits including skills development, job satisfaction and career progression. Over half of respondents agreed that involvement in research inspired them to stay in their profession. However, lack of time, support and motivation were all identified as barriers to participation in research. Areas of research interest were identified. This study highlights the importance of a research culture for job satisfaction and staff retention

    List of Contributors

    No full text
    corecore