104 research outputs found

    Modulated voltage metastable ionization detector

    Get PDF
    The output current from a metastable ionization detector (MID) is applied to a modulation voltage circuit. An adjustment is made to balance out the background current, and an output current, above background, is applied to an input of a strip chart recorder. For low level concentrations, i.e., low detected output current, the ionization potential will be at a maximum and the metastable ionization detector will operate at its most sensitive level. When the detected current from the metastable ionization detector increases above a predetermined threshold level, a voltage control circuit is activated which turns on a high voltage transistor which acts to reduce the ionization potential. The ionization potential applied to the metastable ionization detector is then varied so as to maintain the detected signal level constant. The variation in ionization potential is now related to the concentration of the constituent and a representative amplitude is applied to another input of said strip chart recorder

    Analysis of model Titan atmospheric components using ion mobility spectrometry

    Get PDF
    The Gas Chromatograph-Ion Mobility Spectrometer (GC-IMS) was proposed as an analytical technique for the analysis of Titan's atmosphere during the Cassini Mission. The IMS is an atmospheric pressure, chemical detector that produces an identifying spectrum of each chemical species measured. When the IMS is combined with a GC as a GC-IMS, the GC is used to separate the sample into its individual components, or perhaps small groups of components. The IMS is then used to detect, quantify, and identify each sample component. Conventional IMS detection and identification of sample components depends upon a source of energetic radiation, such as beta radiation, which ionizes the atmospheric pressure host gas. This primary ionization initiates a sequence of ion-molecule reactions leading to the formation of sufficiently energetic positive or negative ions, which in turn ionize most constituents in the sample. In conventional IMS, this reaction sequence is dominated by the water cluster ion. However, many of the light hydrocarbons expected in Titan's atmosphere cannot be analyzed by IMS using this mechanism at the concentrations expected. Research at NASA Ames and PCP Inc., has demonstrated IMS analysis of expected Titan atmospheric components, including saturated aliphatic hydrocarbons, using two alternate sample ionizations mechanisms. The sensitivity of the IMS to hydrocarbons such as propane and butane was increased by several orders of magnitude. Both ultra dry (waterless) IMS sample ionization and metastable ionization were successfully used to analyze a model Titan atmospheric gas mixture

    Novel Peptide Ligands of RGS4 from a Focused One-Bead, One-Compound Library

    Full text link
    Peer Reviewedhttp://deepblue.lib.umich.edu/bitstream/2027.42/65605/1/j.1747-0285.2008.00687.x.pd

    Origin of myofibroblasts in liver fibrosis

    Get PDF
    Most chronic liver diseases of all etiologies result in progressive liver fibrosis. Myofibroblasts produce the extracellular matrix, including type I collagen, which constitutes the fibrous scar in liver fibrosis. Normal liver has little type I collagen and no detectable myofibroblasts, but myofibroblasts appear early in experimental and clinical liver injury. The origin of the myofibroblast in liver fibrosis is still unresolved. The possibilities include activation of endogenous mesenchymal cells including fibroblasts and hepatic stellate cells, recruitment from the bone marrow, and transformation of epithelial or endothelial cells to myofibroblasts. In fact, the origin of myofibroblasts may be different for different types of chronic liver diseases, such as cholestatic liver disease or hepatotoxic liver disease. This review will examine our current understanding of the liver myofibroblast

    Identification of Genes Affecting the Toxicity of Anti-Cancer Drug Bortezomib by Genome-Wide Screening in S. pombe

    Get PDF
    Bortezomib/PS-341/Velcade, a proteasome inhibitor, is widely used to treat multiple myeloma. While several mechanisms of the cytotoxicity of the drug were proposed, the actual mechanism remains elusive. We aimed to identify genes affecting the cytotoxicity of Bortezomib in the fission yeast S.pombe as the drug inhibits this organism's cell division cycle like proteasome mutants. Among the 2815 genes screened (covering 56% of total ORFs), 19 genes, whose deletions induce strong synthetic lethality with Bortezomib, were identified. The products of the 19 genes included four ubiquitin enzymes and one nuclear proteasome factor, and 13 of them are conserved in humans. Our results will provide useful information for understanding the actions of Bortezomib within cells

    Oxidation of DJ-1 Induced by 6-Hydroxydopamine Decreasing Intracellular Glutathione

    Get PDF
    DJ-1, the causative gene of a familial form of Parkinson's disease (PD), has been reported to undergo preferential oxidation of the cysteine residue at position 106 (Cys-106) under oxidative stress; however, details of the molecular mechanisms are not well known. In the present study, mechanisms of DJ-1 oxidation induced by 6-hydroxydopamine (6-OHDA) were investigated by using SH-SY5Y cells. The treatment of these cells with 6-OHDA caused an obvious acidic spot sift of DJ-1 due to its oxidation. However, when catalase, which is an hydrogen peroxide (H2O2)-removing enzyme, was added during the treatment, it failed to prevent the oxidation induced by 6-OHDA, suggesting that electrophilic p-quinone formed from 6-OHDA, but not H2O2, was responsible for the DJ-1 oxidation. Benzoquinone, another electrophilic p-quinone, also induced DJ-1 oxidation. The intracellular glutathione (GSH) levels were significantly decreased by 6-OHDA, irrespective of the presence or absence of catalase. The inhibition of GSH synthesis by buthionine sulfoximine resulted in a decrease in GSH levels and enhancement of DJ-1 oxidation. The pretreatment of cells with N-acetyl-cysteine prevented the loss of intracellular GSH and subsequently DJ-1 oxidation induced by 6-OHDA. Collectively, these results suggest that electrophilic p-quinone formed from 6-OHDA induces DJ-1 oxidation by decreasing intracellular GSH

    Diagnostic Accuracy of Recombinant Immunoglobulin-like Protein A-Based IgM ELISA for the Early Diagnosis of Leptospirosis in the Philippines

    Get PDF
    Background Leptospirosis is an important but largely under-recognized public health problem in the tropics. Establishment of highly sensitive and specific laboratory diagnosis is essential to reveal the magnitude of problem and to improve treatment. This study aimed to evaluate the diagnostic accuracy of a recombinant LigA protein based IgM ELISA during outbreaks in the clinical-setting of a highly endemic country. Methodology/Principal Findings A prospective study was conducted from October 2011 to September 2013 at a national referral hospital for infectious diseases in Manila, Philippines. Patients who were hospitalized with clinically suspected leptospirosis were enrolled. Plasma and urine were collected on admission and/or at discharge and tested using the LigA-IgM ELISA and a whole cellbased IgM ELISA. Sensitivity and specificity of these tests were evaluated with cases diagnosed by microscopic agglutination test (MAT), culture and LAMP as the composite reference standard and blood bank donors as healthy controls: the mean+3 standard deviation optical density value of healthy controls was used as the cut-off limit (0.062 for the LigA-IgM ELISA and 0.691 for the whole cell-based IgM ELISA). Of 304 patients enrolled in the study, 270 (89.1%) were male and the median age was 30.5 years; 167 (54.9%) were laboratory confirmed. The sensitivity and ROC curve AUC for the LigA-IgM ELISA was significantly greater than the whole cell-based IgM ELISA (69.5% vs. 54.3%, p<0.01; 0.90 vs. 0.82, p<0.01) on admission, but not at discharge. The specificity of LigA-IgM ELISA and whole cell-based IgM ELISA were not significantly different (98% vs. 97%). Among 158 MAT negative patients, 53 and 28 were positive by LigA- and whole cell-based IgM ELISA, respectively; if the laboratory confirmation was re-defined by LigA-IgM ELISA and LAMP, the clinical findings were more characteristic of leptospirosis than the diagnosis based on MAT/ culture/LAMP. Conclusions/Significance The newly developed LigA-IgM ELISA is more sensitive than the whole cell-based IgM based ELISA. Although the final diagnosis must be validated by more specific tests, LigAIgM ELISA could be a useful diagnostic test in a real clinical-setting, where diagnosis is needed in the early phase of infection

    Interchange for Joint Research Entitled: Miniature Laser Spectrometer for Stable Isotope Measurements

    No full text
    As a first step in successfully measuring carbon isotopes optically we have previously demonstrated the measurement of C-13/C-12 to a precision of 0.1% using a tunable diode laser and CO2 spectral lines in the 2300/cm spectral region. This precision of 0.1% (1 per mil) for carbon isotopes is a value sufficiently precise to provide important isotopic data of interest to astrobiologists. The precision presently attainable in gases is sufficient to permit our instrument to be used in the measurement of isotopic ratios of interest to astrobiologists as well as geologists and planetary scientists. A small stable isotope laser spectrometer with a 10 cm path gas cell was designed and constructed. The cell was integrated with a liquid nitrogen cooled tunable diode laser and indium antimonide detector for evaluation. Using the small gas cell, preliminary measurements of 13C/12C in CO2 were made employing single-beam sequential acquisitions of the required spectral data. The results indicate an accuracy of 0.1% which is sufficiently high to make meaningful measurements of martian samples. In addition, improvements in the spectrometer gas handling system have been made to markedly reduce C-13/C-12 isotopic fractionation during sample gas cell loading which we expect will lead to further improvements in precision and accuracy. An important part of making isotopic ratio measurements in solid samples using diode lasers is the conversion of the elements of interest to molecules that have absorption spectra in the mid-ir spectral range accessible by tunable diode lasers. In this project we have investigated the necessary sample preparation procedures to extract carbon, an element of astrobiological importance, from model soil compounds and to convert it to CO2, a molecule with appropriate optical absorption characteristics for reliable laser spectrometer isotopic ratio measurements of 13C/12C. We have considered calcium carbonate as a model for a component of the martian regolith, and we have formulated a simple heating protocol for extracting carbon in the form of CO2

    Miniature Laser Spectrometer for Stable Isotope Measurements

    No full text
    As a first step in successfully measuring carbon isotopes optically we have previously demonstrated the measurement of C-13/C-12 to a precision of 0.1% using a tunable diode laser and CO2 spectral lines in the 2300/cm spectral region. This precision of 0.1% (1 per mil) for carbon isotopes is a value sufficiently precise to provide important isotopic data of interest to astrobiologists. The precision presently attainable in gases is sufficient to permit our instrument to be used in the measurement of isotopic ratios of interest to astrobiologists as well as geologists and planetary scientists
    corecore