1,990 research outputs found

    Upgrades of beam diagnostics in support of emittance-exchange experiments at the Fermilab A0 photoinjector

    Get PDF
    The possibility of using electron beam phase space manipulations to support a free-electron laser accelerator design optimization has motivated our research. An on-going program demonstrating the exchange of transverse horizontal and longitudinal emittances at the Fermilab A0 photoinjector has benefited recently from the upgrade of several of the key diagnostics stations. Accurate measurements of these properties upstream and downstream of the exchanger beamline are needed. Improvements in the screen resolution term and reduced impact of the optical system's depth-of-focus by using YAG:Ce single crystals normal to the beam direction will be described. The requirement to measure small energy spreads (<10 keV) in the spectrometer and the exchange process which resulted in bunch lengths less than 500 fs led to other diagnostics performance adjustments and upgrades as well. A longitudinal to transverse exchange example is also reported.Comment: 16 p

    Monolithic single mode interband cascade lasers with wide wavelength tunability

    Get PDF
    Financial support by the European Union in terms of the WideLase project (grant agreement no: 318798) within the Seventh Framework Programme is gratefully acknowledged.Monolithic two-section interband cascade lasers offering a wide wavelength tunability in the wavelength range around 3.7 μm are presented. Stable single mode emission in several wavelength channels was realized using the concept of binary superimposed gratings and two-segment Vernier-tuning. The wavelength selective elements in the two segments were based on specially designed lateral metal grating structures defined by electron beam lithography. A dual-step dry etch process provided electrical separation between the segments. Individual current control of the segments allowed wavelength channel selection as well as continuous wavelength tuning within channels. A discontinuous tuning range extending over 158 nm in up to six discrete wavelength channels was achieved. Mode hop free wavelength tuning up to 14 nm was observed within one channel. The devices can be operated in continuous wave mode up to 30 °C with output powers of 3.5 mW around room temperature.PostprintPeer reviewe

    Prognostic Value of Choline and Betaine Depends on Intestinal Microbiota-Generated Metabolite Trimethylamine-N-Oxide

    Get PDF
    Aims: Recent metabolomics and animal model studies show trimethylamine-N-oxide (TMAO), an intestinal microbiota-dependent metabolite formed from dietary trimethylamine-containing nutrients such as phosphatidylcholine (PC), choline, and carnitine, is linked to coronary artery disease pathogenesis. Our aim was to examine the prognostic value of systemic choline and betaine levels in stable cardiac patients. Methods and Results: We examined the relationship between fasting plasma choline and betaine levels and risk of major adverse cardiac events (MACE = death, myocardial infraction, stroke) in relation to TMAO over 3 years of follow-up in 3903 sequential stable subjects undergoing elective diagnostic coronary angiography. In our study cohort, median (IQR) TMAO, choline, and betaine levels were 3.7 (2.4–6.2)μM, 9.8 (7.9–12.2)μM, and 41.1 (32.5–52.1)μM, respectively. Modest but statistically significant correlations were noted between TMAO and choline (r = 0.33, P \u3c 0.001) and less between TMAO and betaine (r = 0.09, P \u3c 0.001). Higher plasma choline and betaine levels were associated with a 1.9-fold and 1.4-fold increased risk of MACE, respectively (Quartiles 4 vs. 1; P \u3c 0.01, each). Following adjustments for traditional cardiovascular risk factors and high-sensitivity C-reactive protein, elevated choline [1.34 (1.03–1.74), P \u3c 0.05], and betaine levels [1.33 (1.03–1.73), P \u3c 0.05] each predicted increased MACE risk. Neither choline nor betaine predicted MACE risk when TMAO was added to the adjustment model, and choline and betaine predicted future risk for MACE only when TMAO was elevated. Conclusion: Elevated plasma levels of choline and betaine are each associated with incident MACE risk independent of traditional risk factors. However, high choline and betaine levels are only associated with higher risk of future MACE with concomitant increase in TMAO

    γ-Butyrobetaine Is A Proatherogenic Intermediate in Gut Microbial Metabolism of L-Carnitine to TMAO

    Get PDF
    L-carnitine, a nutrient in red meat, was recently reported to accelerate atherosclerosis via a metaorganismal pathway involving gut microbial trimethylamine (TMA) formation and host hepatic conversion into trimethylamine-N-oxide (TMAO). Herein, we show that following L-carnitine ingestion, γ-butyrobetaine (γBB) is produced as an intermediary metabolite by gut microbes at a site anatomically proximal to and at a rate ∼1,000-fold higher than the formation of TMA. Moreover, we show that γBB is the major gut microbial metabolite formed from dietary L-carnitine in mice, is converted into TMA and TMAO in a gut microbiota-dependent manner (like dietary L-carnitine), and accelerates atherosclerosis. Gut microbial composition and functional metabolic studies reveal that distinct taxa are associated with the production of γBB or TMA/TMAO from dietary L-carnitine. Moreover, despite their close structural similarity, chronic dietary exposure to L-carnitine or γBB promotes development of functionally distinct microbial communities optimized for the metabolism of L-carnitine or γBB, respectively

    Joint ancestry and association test indicate two distinct pathogenic pathways involved in classical dengue fever and dengue shock syndrome

    Get PDF
    Ethnic diversity has been long considered as one of the factors explaining why the severe forms of dengue are more prevalent in Southeast Asia than anywhere else. Here we take advantage of the admixed profile of Southeast Asians to perform coupled association-admixture analyses in Thai cohorts. For dengue shock syndrome (DSS), the significant haplotypes are located in genes coding for phospholipase C members (PLCB4 added to previously reported PLCE1), related to inflammation of blood vessels. For dengue fever (DF), we found evidence of significant association with CHST10, AHRR, PPP2R5E and GRIP1 genes, which participate in the xenobiotic metabolism signaling pathway. We conducted functional analyses for PPP2R5E, revealing by immunofluorescence imaging that the coded protein co-localizes with both DENV1 and DENV2 NS5 proteins. Interestingly, only DENV2-NS5 migrated to the nucleus, and a deletion of the predicted top-linking motif in NS5 abolished the nuclear transfer. These observations support the existence of differences between serotypes in their cellular dynamics, which may contribute to differential infection outcome risk. The contribution of the identified genes to the genetic risk render Southeast and Northeast Asian populations more susceptible to both phenotypes, while African populations are best protected against DSS and intermediately protected against DF, and Europeans the best protected against DF but the most susceptible against DSS.The research leading to these results has received funding from the European Commission Seventh Framework Programme [FP7/2007-2013] for the DENFREE project under Grant Agreement no. 282378. MO has a PhD grant from FCT (The Portuguese Foundation for Science and Technology - SFRH/BD/95626/2013). I3S is financed by FEDER - Fundo Europeu de Desenvolvimento Regional funds through the COMPETE 2020 - Competitiveness and Internationalization Operational Programme (POCI), Portugal 2020, and by Portuguese funds through FCT/Ministério da Ciência, Tecnologia e Inovação in the framework of the project "Institute for Research and Innovation in Health Sciences" (POCI-01-0145-FEDER-007274). The funders had no role in study design, data collection and analysis, decision to publish, or preparation of the manuscript

    Mid-infrared GaSb-based resonant tunneling diode photodetectors for gas sensing applications

    Get PDF
    The authors are grateful for financial support by the BMBF via the national project HIRT (FKZ:13XP5003A).We present resonant tunneling diode-photodetectors (RTD-PDs) with GaAs0.15Sb0.85/AlAs0.1Sb0.9 double barrier structures combined with an additional quaternary Ga0.64In0.36As0.33Sb0.67 absorption layer covering the fingerprint absorption lines of various gases in the mid-infrared wavelength spectral region. The absorption layer cut-off wavelength is determined to be 3.5 µm and the RTD-PDs show peak-to-valley current ratios up to 4.3 with peak current densities of 12 A/cm-2.The incorporation of the quaternary absorption layer enables the RTD-PD to be sensitive to illumination with light up to the absorption lines of HCl at 3395 nm. At this wavelength, the detector shows a responsivity of 6.3 mA/W. At the absorption lines of CO2 and CO at 2004 nm and 2330 nm respectively, the RTD-PD reaches responsivities up to 0.97 A/W. Thus RTD-PDs pave the way towards high sensitive mid-infrared detectors that can be utilized in tunable laser absorption spectroscopy.PostprintPeer reviewe

    Business Analytics in (a) Blink

    Get PDF
    The Blink project’s ambitious goal is to answer all Business Intelligence (BI) queries in mere seconds, regardless of the database size, with an extremely low total cost of ownership. Blink is a new DBMS aimed primarily at read-mostly BI query processing that exploits scale-out of commodity multi-core processors and cheap DRAM to retain a (copy of a) data mart completely in main memory. Additionally, it exploits proprietary compression technology and cache-conscious algorithms that reduce memory bandwidth consumption and allow most SQL query processing to be performed on the compressed data. Blink always scans (portions of) the data mart in parallel on all nodes, without using any indexes or materialized views, and without any query optimizer to choose among them. The Blink technology has thus far been incorp

    Demonstration of the self-mixing effect in interband cascade lasers

    Get PDF
    In this Letter, we demonstrate the self-mixing effect in an interband cascade laser. We show that a viable self-mixing signal can be acquired through the variation in voltage across the laser terminals, thereby removing the need for an external detector. Using this interferometric technique, we have measured the displacement of a remote target, and also demonstrated high resolution imaging of a target. The proposed scheme represents a highly sensitive, compact, and self-aligned sensing technique with potential for materials analysis in the mid-infrared. (C) 2013 AIP Publishing LLC
    corecore