12,098 research outputs found

    Longitudinal aerodynamic characteristics of a large scale model with a swept wing and augmented jet flap in ground effect

    Get PDF
    The investigation of the in-ground-effect, longitudinal aerodynamic characteristics of a large scale swept augmentor wing model is presented, using 40 x 80 ft wind tunnel. The investigation was conducted at three ground heights; h/c equals 2.01, 1.61, and 1.34. The induced effect of underwing nacelles, was studied with two powered nacelle configurations. One configuration used four JT-15D turbofans while the other used two J-85 turbojet engines. Two conical nozzles on each J-85 were used to deflect the thrust at angles from 0 to 120 deg. Tests were also performed without nacelles to allow comparison with previous data from ground effect

    Wind tunnel investigation of a large-scale 25 deg swept-wing jet transport model with an external blowing triple-slotted flap

    Get PDF
    An investigation has been conducted to determine the aerodynamic characteristics of a large-scale subsonic jet transport model with an externally blown triple-slotted flap. The lift of the model was augmented by the turbofan engine exhaust impingement on the flap surface. The model had a 25 deg swept wing of aspect ratio 7.28 and four turbofan engines. The model was tested with two flap extents. One extended from 0.11 to 1.00 of the wing semispan, and the other extended from 0.11 to 0.75 of the wing semispan with a single-slotted aileron from 0.75 to 1.00 of the wing semispan. The results were obtained for several flap deflections with and without the horizontal tail at gross thrust coefficients from 0 to 4.0. Longitudinal and lateral data are presented with three and four engines operating

    Acoustic characteristics of a large-scale wind tunnel model of an upper-surface blown flap transport having two engines

    Get PDF
    The upper-surface blown (USB) flap as a powered-lift concept has evolved because of the potential acoustic shielding provided when turbofan engines are installed on a wing upper surface. The results from a wind tunnel investigation of a large-scale USB model powered by two JT15D-1 turbofan engines are-presented. The effects of coanda flap extent and deflection, forward speed, and exhaust nozzle configuration were investigated. To determine the wing shielding the acoustics of a single engine nacelle removed from the model were also measured. Effective shielding occurred in the aft underwing quadrant. In the forward quadrant the shielding of the high frequency noise was counteracted by an increase in the lower frequency wing-exhaust interaction noise. The fuselage provided shielding of the opposite engine noise such that the difference between single and double engine operation was 1.5 PNdB under the wing. The effects of coanda flap deflection and extent, angle of attack, and forward speed were small. Forward speed reduced the perceived noise level (PNL) by reducing the wing-exhaust interaction noise

    Large-scale V/STOL testing

    Get PDF
    Several facets of large-scale testing of V/STOL aircraft configurations are discussed with particular emphasis on test experience in the Ames 40- by 80-Foot Wind Tunnel. Examples of powered-lift test programs are presented in order to illustrate tradeoffs confronting the planner of V/STOL test programs. Large-scale V/STOL wind-tunnel testing can sometimes compete with small-scale testing in the effort required (overall test time) and program costs because of the possibility of conducting a number of different tests with a single large-scale model where several small-scale models would be required. The benefits of both high- or full-scale Reynolds numbers, more detailed configuration simulation, and number and type of onboard measurements are studied

    Protected gates for topological quantum field theories

    Get PDF
    We study restrictions on locality-preserving unitary logical gates for topological quantum codes in two spatial dimensions. A locality-preserving operation is one which maps local operators to local operators --- for example, a constant-depth quantum circuit of geometrically local gates, or evolution for a constant time governed by a geometrically-local bounded-strength Hamiltonian. Locality-preserving logical gates of topological codes are intrinsically fault tolerant because spatially localized errors remain localized, and hence sufficiently dilute errors remain correctable. By invoking general properties of two-dimensional topological field theories, we find that the locality-preserving logical gates are severely limited for codes which admit non-abelian anyons; in particular, there are no locality-preserving logical gates on the torus or the sphere with M punctures if the braiding of anyons is computationally universal. Furthermore, for Ising anyons on the M-punctured sphere, locality-preserving gates must be elements of the logical Pauli group. We derive these results by relating logical gates of a topological code to automorphisms of the Verlinde algebra of the corresponding anyon model, and by requiring the logical gates to be compatible with basis changes in the logical Hilbert space arising from local F-moves and the mapping class group.Comment: 50 pages, many figures, v3: updated to match published versio

    Wind-tunnel investigation of the thrust augmentor performance of a large-scale swept wing model

    Get PDF
    Tests were made in the Ames 40- by 80-foot wind tunnel to determine the forward speed effects on wing-mounted thrust augmentors. The large-scale model was powered by the compressor output of J-85 driven viper compressors. The flap settings used were 15 deg and 30 deg with 0 deg, 15 deg, and 30 deg aileron settings. The maximum duct pressure, and wind tunnel dynamic pressure were 66 cmHg (26 in Hg) and 1190 N/sq m (25 lb/sq ft), respectively. All tests were made at zero sideslip. Test results are presented without analysis

    Acoustic characteristics of a large-scale augmentor wing model at forward speed

    Get PDF
    The augmentor wing concept is being studied as one means of attaining short takeoff and landing (STOL) performance in turbofan powered aircraft. Because of the stringent noise requirements for STOL operation, the acoustics of the augmentor wing are undergoing extensive research. The results of a wind tunnel investigation of a large-scale swept augmentor model at forward speed are presented. The augmentor was not acoustically treated, although the compressor supplying the high pressure primary air was treated to allow the measurement of only the augmentor noise. Installing the augmentor flap and shroud on the slot primary nozzle caused the acoustic dependence on jet velocity to change from eighth power to sixth power. Deflecting the augmentor at constant power increased the perceived noise level in the forward quadrant. The effect of airspeed was small. A small aft shift in perceived noise directivity was experienced with no significant change in sound power. Sealing the lower augmentor slot at a flap deflection of 70 deg reduced the perceived noise level in the aft quadrant. The seal prevented noise from propagating through the slot
    • …
    corecore