5 research outputs found

    Toward Automated Electrode Selection in the Electronic Depth Control Strategy for Multi-unit Recordings

    No full text
    Multi-electrode arrays contain an increasing number of electrodes. The manual selection of good quality signals among hundreds of electrodes becomes impracticable for experimental neuroscientists. This increases the need for an automated selection of electrodes containing good quality signals. To motivate the automated selection, three experimenters were asked to assign quality scores, taking one of four possible values, to recordings containing action potentials obtained from the monkey primary somatosensory cortex and the superior parietal lobule. Krippendorff’s alpha-reliability was then used to verify whether the scores, given by different experimenters, were in agreement. A Gaussian process classifier was used to automate the prediction of the signal quality using the scores of the different experimenters. Prediction accuracies of the Gaussian process classifier are about 80% when the quality scores of different experimenters are combined, through a median vote, to train the Gaussian process classifier. It was found that predictions based also on firing rate features are in closer agreement with the experimenters’ assignments than those based on the signal-to-noise ratio alone.status: publishe

    Discrete cortical responses from multi-site supra-choroidal electrical stimulation in the feline retina

    No full text
    Exploration into electrical stimulation of the retina has thus far focussed primarily upon the development of prostheses targeted at one of two sites of intervention - the epi- and sub-retinal surfaces. These two approaches have sound, logical merit owing to their proximity to retinal neurons and their potential to deliver stimuli via the surviving retinal neural networks respectively. There is increasing evidence, however, that electric field effects, electrode engineering limitations, and electrode-tissue interactions limit the spatial resolution that once was hoped could be elicited from electrical stimulation at epi- and sub-retinal sites. An alternative approach has been proposed that places a stimulating electrode array within the supra-choroidal space - that is, between the sclera and the choroid. Here we investigate whether discrete, cortical activity patterns can be elicited via electrical stimulation of a feline retina using a custom, 14 channel, silicone rubber and Pt electrode array arranged in two hexagons comprising seven electrodes each. Cortical responses from Areas 17/18 were acquired using a silicon-based, multi-channel, penetrating probe developed at IMTEK, University of Freiburg, within the European research project NeuroProbes. Multi-unit spike activity was recorded in synchrony with the presentation of electrical stimuli. Results show that distinct cortical response patterns could be elicited from each hexagon separated by 1.8 mm (center-to-center) with a center-to-center electrode spacing within each hexagon of 0.55 mm. This lends support that higher spatial resolution may also be discerned

    Approaches for drug delivery with intracortical probes

    Get PDF
    Abstract Intracortical microprobes allow the precise monitoring of electrical and chemical signaling and are widely used in neuroscience. Microelectromechanical system (MEMS) technologies have greatly enhanced the integration of multifunctional probes by facilitating the combination of multiple recording electrodes and drug delivery channels in a single probe. Depending on the neuroscientific application, various assembly strategies are required in addition to the microprobe fabrication itself. This paper summarizes recent advances in the fabrication and assembly of micromachined silicon probes for drug delivery achieved within the EU-funded research project NeuroProbes. The described fabrication process combines a two-wafer silicon bonding process with deep reactive ion etching, wafer grinding, and thin film patterning and offers a maximum in design flexibility. By applying this process, three general comb-like microprobe designs featuring up to four 8-mm-long shafts, cross sections from 150×200 to 250×250 µm², and different electrode and fluidic channel configurations are realized. Furthermore, we discuss the development and application of different probe assemblies for acute, semichronic, and chronic applications, including comb and array assemblies, floating microprobe arrays, as well as the complete drug delivery system NeuroMedicator for small animal research.status: publishe
    corecore