9 research outputs found

    Supplemental data for article: Ammonium adduct chemical ionization to investigate anthropogenic oxygenated gas-phase organic compounds in urban air

    No full text
    This file contains ambient timeseries of calibration and uncalibrated ions measured using ammonium adduct chemical ionization in wintertime New York City, and the corresponding wind data.  </p

    Advances in offline approaches for chemically speciated measurements of trace gas-phase organic compounds via adsorbent tubes in an integrated sampling-to-analysis system

    No full text
    Gas-phase organic compounds across a range of volatilities, including volatile organic compounds (VOCs), are key components of outdoor air, indoor spaces, and a variety of other anthropogenic and biogenic systems. The collection of offline samples on adsorbent-packed tubes for analysis on laboratory instrumentation has been in use for decades, but with limited sensitivities and compound coverage. We present and evaluate our integrated sampling-to-analysis system that enables offline detailed chemical characterization of multi-faceted organic mixtures at trace concentrations. Its capabilities extend across a diverse variety of VOCs with different molecular features, as well as intermediate and semivolatile organic compounds (I/SVOCs). Samples can be collected manually or via automated devices that have been applied in chamber, field, and aircraft platforms. The laboratory instrumentation can be coupled to both a high resolution mass spectrometer (MS) and a traditional quadrupole MS, though performance metrics presented in this study are determined via the traditional MS. We demonstrate capabilities for detailed chemical characterization and routine performance for a wide range of compound functionalities at sub-part per trillion (ppt) concentrations, and as low as <100 parts per quadrillion (ppq), yielding 3300 observed unique compound peaks in a single indoor air sample. These limits of detection and compound coverage were accomplished through a holistic optimization of the entire system and lifecycle of adsorbent tubes. We present our best practices for all aspects of tube production, handling, sampling, and analysis, and an examination of commercially-available materials and our custom adsorbent tubes using a diverse mix of VOC, IVOC, and SVOC standards, including difficult to measure analytes across a range of polarities and functionalities. In many aspects, the commercially-available materials and tube conditioners tested were insufficient for achieving low-ppt measurements

    Advances in offline approaches for chemically speciated measurements of trace gas-phase organic compounds via adsorbent tubes in an integrated sampling-to-analysis system

    No full text
    Gas-phase organic compounds across a range of volatilities, including volatile organic compounds (VOCs), are key components of outdoor air, indoor spaces, and a variety of other anthropogenic and biogenic systems. The collection of offline samples on adsorbent-packed tubes for analysis on laboratory instrumentation has been in use for decades, but with limited sensitivities and compound coverage. We present and evaluate our integrated sampling-to-analysis system that enables offline detailed chemical characterization of multi-faceted organic mixtures at trace concentrations. Its capabilities extend across a diverse variety of VOCs with different molecular features, as well as intermediate and semivolatile organic compounds (I/SVOCs). Samples can be collected manually or via automated devices that have been applied in chamber, field, and aircraft platforms. The laboratory instrumentation can be coupled to both a high resolution mass spectrometer (MS) and a traditional quadrupole MS, though performance metrics presented in this study are determined via the traditional MS. We demonstrate capabilities for detailed chemical characterization and routine performance for a wide range of compound functionalities at sub-part per trillion (ppt) concentrations, and as low as <100 parts per quadrillion (ppq), yielding 3300 observed unique compound peaks in a single indoor air sample. These limits of detection and compound coverage were accomplished through a holistic optimization of the entire system and lifecycle of adsorbent tubes. We present our best practices for all aspects of tube production, handling, sampling, and analysis, and an examination of commercially-available materials and our custom adsorbent tubes using a diverse mix of VOC, IVOC, and SVOC standards, including difficult to measure analytes across a range of polarities and functionalities. In many aspects, the commercially-available materials and tube conditioners tested were insufficient for achieving low-ppt measurements

    Characterizing the sources of ambient PM10 organic aerosol in urban and rural Catalonia, Spain

    Get PDF
    Organic aerosols (OA) have recently been shown to be the dominant contributor to the oxidative potential of airborne particulate matter in northeastern Spain. We collected PM10 filter samples every fourth day from January 2017 to March 2018 at two sampling stations located in Barcelona city and Montseny Natural Park, representing urban and rural areas, respectively. The chemical composition of PM10 was analyzed offline using a broad set of analytical instruments, including high-resolution time-of-flight mass spectrometry (HR-ToF-AMS), a total organic carbon analyzer (TCA), inductively coupled plasma atomic emission spectrometry (ICP-AES), inductively coupled plasma mass spectrometry (ICP-MS), ion chromatography (IC), and thermal-optical carbon analyzer. Source apportionment analysis of the water-soluble organic content of the samples measured via HR-ToF-AMS revealed two primary and two secondary sources of OA, which included biomass-burning OA (BBOA), sulfur-containing OA (SCOA), as well as summer- and winter‑oxygenated OA (SOOA and WOOA). The presence of hydrocarbon-like water-insoluble OA was also identified based on concentration trends in black carbon and nitrogen oxides. The results from the source apportionment analysis of the inorganic composition were correlated with different OA factors to assess potential source contributors. Barcelona showed significantly higher average water-soluble OA concentrations (5.63 ± 0.56 μg m-3) than Montseny (3.27 ± 0.37 μg m-3) over the sampling period. WOOA accounted for nearly 27 % of the averaged OA in Barcelona compared to only 7 % in Montseny. In contrast, SOOA had a greater contribution to OA in Montseny (47 %) than in Barcelona (24 %). SCOA and BBOA were responsible for 15–28 % of the OA at both sites. There were also seasonal variations in the relative contributions of different OA sources. Our overall results showed that local anthropogenic sources were primarily responsible for up to 70 % of ambient soluble OA in Barcelona, and regulating local-scale emissions could significantly improve air quality in urban Spain

    An omnipresent diversity and variability in the chemical composition of atmospheric functionalized organic aerosol

    No full text
    The detailed molecular-level speciation of organic aerosol is a highly challenging task. Here, the authors show an extensive molecular-level intercomparison of functionalized organic aerosol from three diverse field sites revealing large compositional variability between samples at each field site
    corecore