689 research outputs found

    Electron Exchange Coupling for Single Donor Solid-State Qubits

    Full text link
    Inter-valley interference between degenerate conduction band minima has been shown to lead to oscillations in the exchange energy between neighbouring phosphorus donor electron states in silicon \cite{Koiller02,Koiller02A}. These same effects lead to an extreme sensitivity of the exchange energy on the relative orientation of the donor atoms, an issue of crucial importance in the construction silicon-based spin quantum computers. In this article we calculate the donor electron exchange coupling as a function of donor position incorporating the full Bloch structure of the Kohn-Luttinger electron wavefunctions. It is found that due to the rapidly oscillating nature of the terms they produce, the periodic part of the Bloch functions can be safely ignored in the Heitler-London integrals as was done by Koiller et. al. [Phys. Rev. Lett. 88,027903(2002),Phys. Rev. B. 66,115201(2002)], significantly reducing the complexity of calculations. We address issues of fabrication and calculate the expected exchange coupling between neighbouring donors that have been implanted into the silicon substrate using an 15keV ion beam in the so-called 'top down' fabrication scheme for a Kane solid-state quantum computer. In addition we calculate the exchange coupling as a function of the voltage bias on control gates used to manipulate the electron wavefunctions and implement quantum logic operations in the Kane proposal, and find that these gate biases can be used to both increase and decrease the magnitude of the exchange coupling between neighbouring donor electrons. The zero-bias results reconfirm those previously obtained by Koiller.Comment: 10 Pages, 8 Figures. To appear in Physical Review

    Time-dependent effects in melting and phase change for laser-shocked iron

    Get PDF
    Using the Linac Coherent Light Source facility at the Stanford Linac Coherent Light Source National Accelerator Laboratory, we have observed X-ray scattering from iron compressed with laser-driven shocks to earth-core-like pressures above 400 GPa. The data show cases where melting is incomplete and we observe hexagonal-close-packed crystal structure at shock compressed densities up to 14.0 g cm-3 but no evidence of a double-hexagonal-close-packed crystal. The observation of a crystalline structure at these densities, where shock heating is expected to be in excess of the equilibrium melt temperature, may indicate superheating of the solid. These results are important for equation of state modeling at high strain rates relevant for impact scenarios and laser-driven shock-wave experiments

    MEG Upgrade Proposal

    Full text link
    We propose the continuation of the MEG experiment to search for the charged lepton flavour violating decay (cLFV) \mu \to e \gamma, based on an upgrade of the experiment, which aims for a sensitivity enhancement of one order of magnitude compared to the final MEG result, down to the 6×10146 \times 10^{-14} level. The key features of this new MEG upgrade are an increased rate capability of all detectors to enable running at the intensity frontier and improved energy, angular and timing resolutions, for both the positron and photon arms of the detector. On the positron-side a new low-mass, single volume, high granularity tracker is envisaged, in combination with a new highly segmented, fast timing counter array, to track positron from a thinner stopping target. The photon-arm, with the largest liquid xenon (LXe) detector in the world, totalling 900 l, will also be improved by increasing the granularity at the incident face, by replacing the current photomultiplier tubes (PMTs) with a larger number of smaller photosensors and optimizing the photosensor layout also on the lateral faces. A new DAQ scheme involving the implementation of a new combined readout board capable of integrating the diverse functions of digitization, trigger capability and splitter functionality into one condensed unit, is also under development. We describe here the status of the MEG experiment, the scientific merits of the upgrade and the experimental methods we plan to use.Comment: A. M. Baldini and T. Mori Spokespersons. Research proposal submitted to the Paul Scherrer Institute Research Committee for Particle Physics at the Ring Cyclotron. 131 Page

    Design, development and verification of the 30 and 44 GHz front-end modules for the Planck Low Frequency Instrument

    Get PDF
    We give a description of the design, construction and testing of the 30 and 44 GHz Front End Modules (FEMs) for the Low Frequency Instrument (LFI) of the Planck mission to be launched in 2009. The scientific requirements of the mission determine the performance parameters to be met by the FEMs, including their linear polarization characteristics. The FEM design is that of a differential pseudo-correlation radiometer in which the signal from the sky is compared with a 4-K blackbody load. The Low Noise Amplifier (LNA) at the heart of the FEM is based on indium phosphide High Electron Mobility Transistors (HEMTs). The radiometer incorporates a novel phase-switch design which gives excellent amplitude and phase match across the band. The noise temperature requirements are met within the measurement errors at the two frequencies. For the most sensitive LNAs, the noise temperature at the band centre is 3 and 5 times the quantum limit at 30 and 44 GHz respectively. For some of the FEMs, the noise temperature is still falling as the ambient temperature is reduced to 20 K. Stability tests of the FEMs, including a measurement of the 1/f knee frequency, also meet mission requirements. The 30 and 44 GHz FEMs have met or bettered the mission requirements in all critical aspects. The most sensitive LNAs have reached new limits of noise temperature for HEMTs at their band centres. The FEMs have well-defined linear polarization characteristcs.Comment: 39 pages, 33 figures (33 EPS files), 12 tables. Planck LFI technical papers published by JINST: http://www.iop.org/EJ/journal/-page=extra.proc5/1748-022

    Advanced modelling of the Planck-LFI radiometers

    Get PDF
    The Low Frequency Instrument (LFI) is a radiometer array covering the 30-70 GHz spectral range on-board the ESA Planck satellite, launched on May 14th, 2009 to observe the cosmic microwave background (CMB) with unprecedented precision. In this paper we describe the development and validation of a software model of the LFI pseudo-correlation receivers which enables to reproduce and predict all the main system parameters of interest as measured at each of the 44 LFI detectors. These include system total gain, noise temperature, band-pass response, non-linear response. The LFI Advanced RF Model (LARFM) has been constructed by using commercial software tools and data of each radiometer component as measured at single unit level. The LARFM has been successfully used to reproduce the LFI behavior observed during the LFI ground-test campaign. The model is an essential element in the database of LFI data processing center and will be available for any detailed study of radiometer behaviour during the survey.Comment: 21 pages, 15 figures, this paper is part of the Prelaunch status LFI papers published on JINST: http://www.iop.org/EJ/journal/-page=extra.proc5/jins

    Bottlenecks in granular flow: When does an obstacle increase the flowrate in an hourglass?

    Full text link
    Bottlenecks occur in a wide range of applications from pedestrian and traffic flow to mineral and food processing. We examine granular flow across a bottleneck using particle-based simulations. Contrary to expectations we find that the flowrate across a bottleneck actually increases if an opti- mized obstacle is placed before it. The dependency of flowrate on obstacle diameter is derived using a phenomenological velocity-density relationship that peaks at a critical density. This relationship is in stark contrast to models of traffic flow, as the mean velocity does not depend only on density but attains hysteresis due to interaction of particles with the obstacle.Comment: Submitted to Phys. Rev. Let

    Industrial work placement in higher education: a study of civil engineering student engagement

    Get PDF
    For civil engineering undergraduates, the opportunity to spend a period of time in formal industrial work placement provides an invaluable learning experience. This paper reviews student engagement with short-term industrial placement and provides analysis of questionnaires (n=174) returned by undergraduates studying civil engineering at four Higher Education Institutes (HEI’s) in the West of Scotland. The data captures industrial placement statistics, employability skill-sets and presents brief testimonies from students. Whilst the journey to becoming a professional civil engineer is undoubtedly enhanced by short-term placement clear opportunities exist for HEI’s to affect and change existing pedagogical discourse. Commentary is likely to resonate beyond civil engineering and serve as a timely reminder of the need to re-invigorate academia / industry curriculum partnerships

    New constraint on the existence of the mu+-> e+ gamma decay

    Get PDF
    The analysis of a combined data set, totaling 3.6 \times 10^14 stopped muons on target, in the search for the lepton flavour violating decay mu^+ -> e^+ gamma is presented. The data collected by the MEG experiment at the Paul Scherrer Institut show no excess of events compared to background expectations and yield a new upper limit on the branching ratio of this decay of 5.7 \times 10^-13 (90% confidence level). This represents a four times more stringent limit than the previous world best limit set by MEG.Comment: 5 pages, 3 figures, a version accepted in Phys. Rev. Let

    The MEG detector for μ+e+γ{\mu}+\to e+{\gamma} decay search

    Get PDF
    The MEG (Mu to Electron Gamma) experiment has been running at the Paul Scherrer Institut (PSI), Switzerland since 2008 to search for the decay \meg\ by using one of the most intense continuous μ+\mu^+ beams in the world. This paper presents the MEG components: the positron spectrometer, including a thin target, a superconducting magnet, a set of drift chambers for measuring the muon decay vertex and the positron momentum, a timing counter for measuring the positron time, and a liquid xenon detector for measuring the photon energy, position and time. The trigger system, the read-out electronics and the data acquisition system are also presented in detail. The paper is completed with a description of the equipment and techniques developed for the calibration in time and energy and the simulation of the whole apparatus.Comment: 59 pages, 90 figure
    corecore