286 research outputs found

    Safety profile of a miniaturized insertable cardiac monitor: results from two prospective trials

    Get PDF
    BACKGROUND: Insertable cardiac monitors (ICM) are used to continuously monitor the patient's ECG. In response to patient activation or based on automated device algorithms, arrhythmia episodes are stored and automatically transmitted daily to the clinician. Thus, ICMs can be used to diagnose arrhythmias in at-risk patients and in those with symptoms potentially attributable to arrhythmias. The ICM described in the present report has undergone a dramatic change in size and method of insertion. METHODS: To evaluate the safety profile of the ICM procedure, we analyzed procedure-related adverse events from two separate trials: a controlled, non-randomized multicenter study (Reveal LINQ™ Usability study) and a multicenter registry (Reveal LINQ™ Registry) evaluating real-world experience. For the Registry we reported all procedure-related adverse events upon occurrence, whereas for the Usability study, we reported events occurring during the first month of follow-up. RESULTS: The Usability study enrolled 151 patients (age 56.6 ± 12.1 years; male 67%) at 16 centers; during follow-up, an infection was observed in 1.3% patients and a procedure-related serious adverse event (SAE) in 0.7% patients. The Registry enrolled 122 patients (age 61.0 ± 17.8 years; male 47%) at 7 centers; during follow-up, an infection was observed in 1.6% patients and a procedure-related SAE in 1.6% patients. CONCLUSIONS: The cumulative experience from a controlled clinical trial and a "real-world" registry, demonstrate that the new ICM can be inserted with very low incidence of adverse events.Suneet Mittal, Prashanthan Sanders, Evgeny Pokushalov, Lukas Dekker, Dean Kereiakes, Edward J. Schloss, Erika Pouliot, Noreli Franco, Yan Zhong, Marco Di Bacco and Helmut Pürerfellne

    In Vitro Photodynamic Therapy with Chlorin e6 Leads to Apoptosis of Human Vascular Smooth Muscle Cells

    Get PDF
    Percutaneous coronary intervention has become the most common and widely implemented method of heart revascularization. However, the development of restenosis remains the major limitation of this method. Photodynamic therapy (PDT) recently emerged as a new and promising method for the prevention of arterial restenosis. Here the efficacy of chlorin e6 in PDT was investigated in vitro using human vascular smooth muscle cells (TG/HA-VSMCs) as one of the cell types crucial in the development of restenosis. PDT-induced cell death was studied on many levels, including annexin V staining, measurement of the generation reactive oxygen species (ROS) and caspase-3 activity, and assessment of changes in mitochondrial membrane potential and fragmentation of DNA. Photosensitization of TG/HA-VSMCs with a 170 μM of chlorin e6 and subsequent illumination with the light of a 672-nm diode laser (2 J/cm2) resulted in the generation of ROS, a decrease in cell membrane polarization, caspase-3 activation, as well as DNA fragmentation. Interestingly, the latter two apoptotic events could not be observed in photosensitized and illuminated NIH3T3 fibroblasts, suggesting different outcomes of the model of PDT in various types of cells. The results obtained with human VSMCs show that chlorin e6 may be useful in the PDT of aerial restenosis, but its efficacy still needs to be established in an animal model

    Efficacy and safety of alirocumab in insulin-treated patients with type 1 or type 2 diabetes and high cardiovascular risk:Rationale and design of the ODYSSEY DM-INSULIN trial

    Get PDF
    Aims: The coadministration of alirocumab, a PCSK9 inhibitor for treatment of hypercholesterolaemia, and insulin in diabetes mellitus (DM) requires further study. Described here is the rationale behind a phase-IIIb study designed to characterize the efficacy and safety of alirocumab in insulin-treated patients with type 1 (T1) or type 2 (T2) DM with hypercholesterolaemia and high cardiovascular (CV) risk. Methods: ODYSSEY DM-INSULIN (NCT02585778) is a randomized, double-blind, placebo-controlled, multicentre study that planned to enrol around 400 T2 and up to 100 T1 insulin-treated DM patients. Participants had low-density lipoprotein cholesterol (LDL-C) levels at screening. ≥. 70. mg/dL (1.81. mmol/L) with stable maximum tolerated statin therapy or were statin-intolerant, and taking (or not) other lipid-lowering therapy; they also had established CV disease or at least one additional CV risk factor. Eligible patients were randomized 2:1 to 24. weeks of alirocumab 75. mg every 2. weeks (Q2W) or a placebo. Alirocumab-treated patients with LDL-C. ≥. 70. mg/dL at week 8 underwent a blinded dose increase to 150. mg Q2W at week 12. Primary endpoints were the difference between treatment arms in percentage change of calculated LDL-C from baseline to week 24, and alirocumab safety. Results: This is an ongoing clinical trial, with 76 T1 and 441 T2 DM patients enrolled; results are expected in mid-2017. Conclusion: The ODYSSEY DM-INSULIN study will provide information on the efficacy and safety of alirocumab in insulin-treated individuals with T1 or T2 DM who are at high CV risk and have hypercholesterolaemia not adequately controlled by the maximum tolerated statin therapy

    A prospective evaluation of the safety and efficacy of the TAXUS Element paclitaxel-eluting coronary stent system for the treatment of de novo coronary artery lesions: Design and statistical methods of the PERSEUS clinical program

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Paclitaxel-eluting stents decrease angiographic and clinical restenosis following percutaneous coronary intervention compared to bare metal stents. TAXUS Element is a third-generation paclitaxel-eluting stent which incorporates a novel, thinner-strut, platinum-enriched metal alloy platform. The stent is intended to have enhanced radiopacity and improved deliverability compared to other paclitaxel-eluting stents. The safety and efficacy of the TAXUS Element stent are being evaluated in the pivotal PERSEUS clinical trials.</p> <p>Methods/Design</p> <p>The PERSEUS trials include two parallel studies of the TAXUS Element stent in single, de novo coronary atherosclerotic lesions. The PERSEUS Workhorse study is a prospective, randomized (3:1), single-blind, non-inferiority trial in subjects with lesion length ≤28 mm and vessel diameter ≥2.75 mm to ≤4.0 mm which compares TAXUS Element to the TAXUS Express<sup>2 </sup>paclitaxel-eluting stent system. The Workhorse study employs a novel Bayesian statistical approach that uses prior information to limit the number of study subjects exposed to the investigational device and thus provide a safer and more efficient analysis of the TAXUS Element stent. PERSEUS Small Vessel is a prospective, single-arm, superiority trial in subjects with lesion length ≤20 mm and vessel diameter ≥2.25 mm to <2.75 mm that compares TAXUS Element with a matched historical bare metal Express stent control.</p> <p>Discussion</p> <p>The TAXUS PERSEUS clinical trial program uses a novel statistical approach to evaluate whether design and metal alloy iterations in the TAXUS Element stent platform provide comparable safety and improved procedural performance compared to the previous generation Express stent. PERSEUS trial enrollment is complete and primary endpoint data are expected in 2010. PERSEUS Workhorse and Small Vessel are registered at <url>http://www.clinicaltrials.gov</url>, identification numbers NCT00484315 and NCT00489541.</p

    Minimizing the risk of inappropriately administering thrombolytic therapy (Thrombolysis and Angioplasty in Myocardial Infarction [TAMI] study group)

    Full text link
    Despite the proven benefits of thrombolytic therapy in acute myocardial infarction, concern for its complications, especially in patients misdiagnosed with myocardial infarction, has led to hesitancy in its use. Historical, clinical and electrocardiographic criteria were developed for enrolling patients with suspected acute myocardial infarction into thrombolytic trials by noncardiovascular specialists. The incidence of misdiagnosis of myocardial infarction and the clinical outcomes when these criteria were used were evaluated for 1,387 consecutive patients given thrombolytic therapy. Twenty-five community hospitals and 7 interventional centers were the sites of enrollment. Most patients (63%) were enrolled from community hospitals. Criteria for thrombolytic therapy included: symptoms of acute myocardial infarction 20 minutes, and not relieved by nitroglycerin; and ST-segment elevation &gt;=1 mm in 2 contiguous leads or ST-segment depression of posterior myocardial infarction. Exclusion criteria reflecting increased risk of bleeding were used. A final diagnosis of myocardial infarction was based on creatinine kinase-MB, electrocardiographic and ventriculographic evaluation. Acute myocardial infarction was misdiagnosed in 20 patients (1.4%; 95% confidence interval 0.8-2.0%). These patients were demographically similar to those with acute myocardial infarction. All misdiagnosed patients survived; no significant adverse events occurred. Thus, in several clinical settings, a simple algorithm with specific criteria was used for diagnosing acute myocardial infarction and administering thrombolytic therapy. The inclusion criteria used in this study led to a low rate of misdiagnosis.Peer Reviewedhttp://deepblue.lib.umich.edu/bitstream/2027.42/30893/1/0000562.pd

    Evaluation of in-stent restenosis in the APPROACH trial (assessment on the prevention of progression by Rosiglitazone on atherosclerosis in diabetes patients with cardiovascular history)

    Get PDF
    To determine (1) the medium-term effect of rosiglitazone and glipizide on intra-stent neointima hyperplasia, (2) restenosis pattern as assessed by intra-vascular ultrasound (IVUS) and quantitative coronary angiography (QCA) in patients with T2DM and coronary artery disease. A total of 462 patients with T2DM were randomized to rosiglitazone or glipizide for up to 18 months in the APPROACH trial, and had evaluable baseline and follow-up IVUS examinations. There was no significant difference in the size of plaque behind stent between the rosiglitazone and glipizide groups at 18 months among those treated with a bare metal stent (−5.6 mm3 vs. 1.9 mm3; P = 0.61) or with a drug-eluting stent (12.1 mm3 vs. 5.5 mm3; P = 0.09). Similarly, there was no significant difference in percentage intimal hyperplasia volume between the rosiglitazone and glipizide groups at 18 months among those treated with a bare metal stent (24.1% vs. 19.8%; P = 0.38) or with a drug-eluting stent (9.8% vs. 8.3%; P = 0.57). QCA data (intra-stent late loss, intra-stent diameter stenosis or binary restenosis) were not different between the rosiglitazone and glipizide groups. This study suggests that both rosiglitazone and glipizide have a similar effect on neointimal growth at medium term follow-up, a finding that warrants investigation in dedicated randomized trials

    Transcatheter or surgical aortic-valve replacement in intermediate-risk patients

    Get PDF
    BACKGROUND: Previous trials have shown that among high-risk patients with aortic stenosis, survival rates are similar with transcatheter aortic-valve replacement (TAVR) and surgical aorticvalve replacement. We evaluated the two procedures in a randomized trial involving intermediate-risk patients. METHODS: We randomly assigned 2032 intermediate-risk patients with severe aortic stenosis, at 57 centers, to undergo either TAVR or surgical replacement. The primary end point was death from any cause or disabling stroke at 2 years. The primary hypothesis was that TAVR would not be inferior to surgical replacement. Before randomization, patients were entered into one of two cohorts on the basis of clinical and imaging findings; 76.3% of the patients were included in the transfemoral-access cohort and 23.7% in the transthoracic-access cohort. RESULTS: The rate of death from any cause or disabling stroke was similar in the TAVR group and the surgery group (P=0.001 for noninferiority). At 2 years, the Kaplan–Meier event rates were 19.3% in the TAVR group and 21.1% in the surgery group (hazard ratio in the TAVR group, 0.89; 95% confidence interval [CI], 0.73 to 1.09; P=0.25). In the transfemoralaccess cohort, TAVR resulted in a lower rate of death or disabling stroke than surgery (hazard ratio, 0.79; 95% CI, 0.62 to 1.00; P=0.05), whereas in the transthoracic-access cohort, outcomes were similar in the two groups. TAVR resulted in larger aortic-valve areas than did surgery and also resulted in lower rates of acute kidney injury, severe bleeding, and new-onset atrial fibrillation; surgery resulted in fewer major vascular complications and less paravalvular aortic regurgitation. CONCLUSIONS: In intermediate-risk patients, TAVR was similar to surgical aortic-valve replacement with respect to the primary end point of death or disabling stroke. (Funded by Edwards Lifesciences; PARTNER 2 ClinicalTrials.gov number, NCT01314313
    corecore