5 research outputs found

    Prevalence of hepatitis B and C viruses among migrant workers in Qatar.

    Get PDF
    Limited data exist on viral hepatitis among migrant populations. This study investigated the prevalence of current hepatitis B virus (HBV) infection and lifetime hepatitis C virus (HCV) infection among Qatar's migrant craft and manual workers (CMWs), constituting 60% of the country's population. Sera collected during a nationwide COVID-19 population-based cross-sectional survey on CMWs between July 26 and September 9, 2020, underwent testing for HBsAg and HCV antibodies. Reactive samples underwent confirmatory testing, and logistic regression analyses were employed to explore associations with HBV and HCV infections. Among 2528 specimens tested for HBV infection, 15 were reactive, with 8 subsequently confirmed positive. Three samples lacked sufficient sera for confirmatory testing but were included in the analysis through multiple imputations. Prevalence of current HBV infection was 0.4% (95% CI 0.2-0.7%). Educational attainment and occupation were significantly associated with current HBV infection. For HCV infection, out of 2607 specimens tested, 46 were reactive, and 23 were subsequently confirmed positive. Prevalence of lifetime HCV infection was 0.8% (95% CI 0.5-1.2%). Egyptians exhibited the highest prevalence at 6.5% (95% CI 3.1-13.1%), followed by Pakistanis at 3.1% (95% CI 1.1-8.0%). Nationality, geographic location, and occupation were significantly associated with lifetime HCV infection. HBV infection is relatively low among CMWs, while HCV infection falls within the intermediate range, both compared to global and regional levels.This work was supported by the National Priorities Research Program (NPRP) [grant number 12S-0216-190094] from the Qatar National Research Fund (a member of Qatar Foundation), and the Undergraduate Research Experience Program UREP30-041-3-014 from Qatar Research, Development and Innovation (QRDI) Council. The authors are also grateful for support from the Biomedical Research Program and the Biostatistics, Epidemiology, and Biomathematics Research Core, both at Weill Cornell Medicine-Qatar, as well as for support provided by the Ministry of Public Health and Hamad Medical Corporation. HHA acknowledges the support of Qatar University internal grant QUCG-CAS-23/24-114. The funders of the study had no role in study design, data collection, data analysis, data interpretation, or writing of the article. Statements made herein are solely the responsibility of the authors. All kits (except Abia HCV Ab) employed in this project were provided at no cost as in-kind support for GKN Lab

    The DAQ and control system for the CMS Phase-1 pixel detector upgrade

    Get PDF
    Abstract: In 2017 a new pixel detector was installed in the CMS detector. This so-called Phase-1 pixel detector features four barrel layers in the central region and three disks per end in the forward regions. The upgraded pixel detector requires an upgraded data acquisition (DAQ) system to accept a new data format and larger event sizes. A new DAQ and control system has been developed based on a combination of custom and commercial microTCA parts. Custom mezzanine cards on standard carrier cards provide a front-end driver for readout, and two types of front-end controller for configuration and the distribution of clock and trigger signals. Before the installation of the detector the DAQ system underwent a series of integration tests, including readout of the pilot pixel detector, which was constructed with prototype Phase-1 electronics and operated in CMS from 2015 to 2016, quality assurance of the CMS Phase-1 detector during its assembly, and testing with the CMS Central DAQ. This paper describes the Phase-1 pixel DAQ and control system, along with the integration tests and results. A description of the operational experience and performance in data taking is included

    The DAQ and control system for the CMS Phase-1 pixel detector upgrade

    No full text
    In 2017 a new pixel detector was installed in the CMS detector. This so-called Phase-1 pixel detector features four barrel layers in the central region and three disks per end in the forward regions. The upgraded pixel detector requires an upgraded data acquisition (DAQ) system to accept a new data format and larger event sizes. A new DAQ and control system has been developed based on a combination of custom and commercial microTCA parts. Custom mezzanine cards on standard carrier cards provide a front-end driver for readout, and two types of front-end controller for configuration and the distribution of clock and trigger signals. Before the installation of the detector the DAQ system underwent a series of integration tests, including readout of the pilot pixel detector, which was constructed with prototype Phase-1 electronics and operated in CMS from 2015 to 2016, quality assurance of the CMS Phase-1 detector during its assembly, and testing with the CMS Central DAQ. This paper describes the Phase-1 pixel DAQ and control system, along with the integration tests and results. A description of the operational experience and performance in data taking is included
    corecore