42 research outputs found

    Processing and characterization of a new biodegradable composite made of a PHB/V matrix and regenerated cellulosic fibers

    Get PDF
    In this study, a biodegradable composite consisting of a degradable continuous cellulosic fiber and a degradable polymer matrix—poly(3-hydroxybutyrate)-co-poly(3-hydroxyvalerate (PHB/V with 19% HV)—was developed. The composite was processed by impregnating the cellulosic fibers on-line withPHB/V powder in a fluidization chamber. The impregnated roving was then filament wound on a plate and hot-pressed. The resulting unidirectional composite plates were mechanically tested and optically characterized by SEM. The fiber content was 9.9 ±0.9 vol% by volumetric determination. The fiber content predicted by the rule of mixture for unidirectional composites was 13.8 ±1.4 vol%. Optical characterization showed that the fiber distribution was homogeneous and a satisfactory wetting of the fibers by the matrix was achieved. Using a blower to remove excess matrix powder during processing increased the fiber content to 26.5 ±3.3 vol % (volumetric) or 30.0 ±0.4 vol% (rule of mixture). The tensile strength of the composite parallel to the fiber direction was 128 ±12 MPa (10 vol% fiber) up to 278 ±48 MPa (26.5 vol% fiber), compared to 20 MPa for the PHB/V matrix. The Young's modulus was 5.8 ±0.5 GPa (10 vol% fiber) and reached 11.4 ±0.14 GPa (26.5 vol% fiber), versus 1 GPa for the matri

    Development of a Fiber Laser with Independently Adjustable Properties for Optical Resolution Photoacoustic Microscopy

    Get PDF
    Photoacoustic imaging is based on the detection of generated acoustic waves through thermal expansion of tissue illuminated by short laser pulses. Fiber lasers as an excitation source for photoacoustic imaging have recently been preferred for their high repetition frequencies. Here, we report a unique fiber laser developed specifically for multiwavelength photoacoustic microscopy system. The laser is custom-made for maximum flexibility in adjustment of its parameters; pulse duration (5–10 ns), pulse energy (up to 10 μJ) and repetition frequency (up to 1 MHz) independently from each other and covers a broad spectral region from 450 to 1100 nm and also can emit wavelengths of 532, 355, and 266 nm. The laser system consists of a master oscillator power amplifier, seeding two stages; supercontinuum and harmonic generation units. The laser is outstanding since the oscillator, amplifier and supercontinuum generation parts are all-fiber integrated with custom-developed electronics and software. To demonstrate the feasibility of the system, the images of several elements of standardized resolution test chart are acquired at multiple wavelengths. The lateral resolution of optical resolution photoacoustic microscopy system is determined as 2.68 μm. The developed system may pave the way for spectroscopic photoacoustic microscopy applications via widely tunable fiber laser technologies

    Development of a Fiber Laser with Independently Adjustable Properties for Optical Resolution Photoacoustic Microscopy

    Get PDF
    Photoacoustic imaging is based on the detection of generated acoustic waves through thermal expansion of tissue illuminated by short laser pulses. Fiber lasers as an excitation source for photoacoustic imaging have recently been preferred for their high repetition frequencies. Here, we report a unique fiber laser developed specifically for multiwavelength photoacoustic microscopy system. The laser is custom-made for maximum flexibility in adjustment of its parameters; pulse duration (5-10 ns), pulse energy (up to 10 μJ) and repetition frequency (up to 1 MHz) independently from each other and covers a broad spectral region from 450 to 1100 nm and also can emit wavelengths of 532, 355, and 266 nm. The laser system consists of a master oscillator power amplifier, seeding two stages; supercontinuum and harmonic generation units. The laser is outstanding since the oscillator, amplifier and supercontinuum generation parts are all-fiber integrated with custom-developed electronics and software. To demonstrate the feasibility of the system, the images of several elements of standardized resolution test chart are acquired at multiple wavelengths. The lateral resolution of optical resolution photoacoustic microscopy system is determined as 2.68 μm. The developed system may pave the way for spectroscopic photoacoustic microscopy applications via widely tunable fiber laser technologies. © The Author(s) 2016

    Recent advances in glycopolypeptide synthesis

    Full text link
    Glycosylated peptides and proteins are ubiquitous in nature and display a wide range of biological functions including mediation of recognition events, protection from proteases, and lubrication in eyes and joints. Similarly, synthetic glycopolypeptides are also expected to show great potential as biomedical materials (e.g. scaffolds for tissue repair and drug carriers), as well as serve as valuable tools for probing carbohydrate-protein interactions. Although block copolypeptides and other complex polypeptide architectures have been known for some time, the synthesis of complex and well-defined glycopolypeptide materials, until recently, has been challenging. This article reviews the many advances and accomplishments made in the past few years toward development of strategies and methods for the preparation of synthetic glycopolypeptides via ring opening polymerization. © 2014 The Royal Society of Chemistry

    A Survey on Electric Vehicle Powertrain Systems

    No full text
    This study covers various aspects of powertrain systems for battery electric vehicles with main focus on front axes driven vehicles. A brief comparison of conventional and electrical powertrain regarding the driveability issues is presented in order to indicate the performance benefits of electrical machines into the vehicle applications. System level differences between internal combustion engine and electrical machine are given. As the most commonly used electrical machine types, a comparison of induction machine and interior permanent magnet synchronous machine is given. Main features of motor drives in industrial and electric vehicle applications are compared and system integration issues are discussed As case study, electric version of FIAT New Doblo is presented including the test results on acceleration performance. Impact of vehicle weight on traction power demand is analysed both analytically and experimentally. Important research and development fields for motor drives in electric vehicles are highlighted considering the cost reduction, efficiency and reliability issues in automotive
    corecore