92 research outputs found

    Healthy Workplace Healthy Workers: Balance for Productivity Enhancement – A Case Study of Garment Manufacturing Units in North India

    Get PDF
    The textile and garment industry in India contributes 14% to industrial production, 5% to GDP and 11% to the country’s export earnings. It provides employment for over 45 million people at various skill levels. The garment manufacturing industry of North India has established itself as a majorapparel sourcing destination for the global markets. The hypothetical projection is that work conditions are usually unsafe and unhealthy.The workstations in the well established industries tend to be poorly designed with uncomfortable work tables and chairs,lack of ventilation, inappropriate lighting, and excessive noise. This kind of a poor working environment impacts adversely on the performance of the workers over long durations. Consequently it reduces the productivity of themanufacturing units. Focus The focus of this paper is to conduct an environmental audit in several sections of the garment industry to ascertain how favourable is the working environment of the workers. Environmental parameters like noise level, illumination and temperaturewere calibrated on instruments like sound level meter, luxmeter and hand held thermometer. The readings were subsequently compared against OSHA(Occupational Safety and Health Administration) standards. Method The review of literature and interactions with the industry experts was the method of enquiry adopted to collect data on the work environment in a majority of the garment manufacturing industries. Findings The research findings showed that the workstations were consistently having congestedwork areas, poor illumination, high temperatures and inadequate ventilation. Scope The scope of this study is to suggest appropriate intervention strategies to improve health, safety and comfort levels of the workers in the garment manufacturing units in various parts of North India in general and Punjab in Particular

    Three Dimensional Gait Assessment During Walking of Healthy People and Drop Foot Patients

    Get PDF
    The aim of the present study is to clinical gait analysis of normal human and drop foot patients. Gait analysis is the systematic study of animal locomotion, more specifically the study of human motion, using the eye and the brain of observers, augmented by instrumentation for measuring body movements, body mechanics, and the activity of the muscles. Gait analysis is used to assess, plan, and treat individuals with conditions affecting their ability to walk. Foot drop is a deceptively simple name for a potentially complex problem. It can be defined as a significant weakness of ankle and toe dorsiflexion. The foot and ankle dorsiflexors include the tibialis anterior, the extensor hallucis longus (EHL), and the extensor digitorum longus (EDL). These muscles help the body clear the foot during the swing phase and control plantar flexion of the foot at heel strik

    Design and Fabrication of Prosthetic and Orthotic Product by 3D Printing

    Get PDF
    In the clinical field, 3D Printing producing is a progressive innovation for various applications, specifically on account of its capacity to customize. From bioprinting to the making of clinical items, for example, inserts, prostheses, or orthoses, it is having a significant effect. Given that there are many energizing activities and organizations in every one of these territories today we will present to you a positioning of the best 3D printed orthoses. Dissimilar to prostheses that supplant a non-existent piece of the body, orthoses are clinical gadgets that are made to settle, soothe, immobilize, control, or right a piece of the body. Since every patient is unique, 3D printing is especially appropriate for these kinds of items and gadgets. Requiring an orthotic or prosthetic item likely methods a work concentrated, tedious, and chaotic procedure. For makers, creating great fitting orthotic and prosthetic gadgets is costly and requires profoundly gifted staff. Patients can anticipate that to a lesser degree a hold up should get their gadget, fewer fittings, and improved sturdiness. Developing a comfortable, properly fitting prosthesis is not just a science, it is also an art. 3D printing has the power to take today’s bespoke, artisanal manufacturing process and transform it into a highly repeatable and consistent process, which ultimately results in more effective clinics and better patient outcomes

    Optimization of the cycle time of robotics resistance spot welding for automotive applications

    Get PDF
    In the automobile manufacturing industry, resistance spot welding (RSW) is widely used, especially to build the car's body. The RSW is a standard and wide‐ranging joining technique in several assembling ventures, showing a wide range of possibilities for a competent procedure. Robots are commonly used for spot welding in various industrial applications. After completing assembling design, interest increases to improve the designed processes, cost‐reduction, environmental impact, and increase time productivity when all is said to be done. In this paper, the robot movement between two welding points, a path followed while spotting, gripping and payload‐carrying activities, numbers of holds, moves, and a possibility to enhance interaction between four Robots were analyzed using an offline Robot simulation software 'DELMIA‐V5'. The body shop assembly line of the SML ISUZU plant has four robots that perform about 209 welding spots in 532 sec. The optimal model reduced the whole welding cycle time by 68 sec, and after modification and proper sequencing, a12.7% reduction in cycle time was achieved. The offline Robot simulation software 'DELMIA‐V5' has good potential to produce optimal algorithms while saving precious time. It enables an organization to promote higher quality and to encourage meaningful creativity by reducing design flaws

    Vibration exposure and transmissibility on dentist's anatomy : a study of micro motors and air-turbines

    Get PDF
    The use of dental hand pieces endanger dentists to vibration exposure as they are subjected to very high amplitude and vibration frequency. This paper has envisaged a comparative analysis of vibration amplitudes and transmissibility during idling and drilling with micro motor (MM) and air-turbine (AT) hand pieces. The study aims to identify the mean difference in vibration amplitudes during idling, explore different grasp forces while drilling with irrigant injection by the dentist, and various vibration transmission of these hand pieces. The study utilized 22 separate frequency resonances on two new and eight used MMs and two new and eight used ATs of different brands by observing the investigator at 16 different dentist clinics. The study adopted a descriptive research design with non–probability sampling techniques for selecting dentists and hand pieces. Statistical methods like Levene Test of Homogeneity, Welch ANOVA, independent t-test, and Games–Howell test were utilized with SPSS version 22 and MS-Excel. The results reveal that vibration amplitudes and vibration transmissibility when measured at position 2 are higher than in another position 1. Vibrations during idling for used MMs are more than AT hand pieces, and the used MM (MUD) and used AT (AUA) hand pieces differ due to their obsolescence and over-usage. Vibration amplitudes increase every time with the tightening of grasping of the hand piece. Vibration amplitudes for each grasping style of MM hand piece differ from all other grasping styles of AT hand pieces. Routine exposure to consistent vibrations has ill physical, mental, and psychological effects on dentists. The used hand pieces more hazardous as compared to newer ones. The study suggests that these hand pieces must be replaced periodically, sufficient to break between two operations, especially after every hand piece usage. Hence, the present research work can be further extended by creating some control groups among dentists and then studying the vibration amplitude exposure of various dental hand pieces and subsequent transmissibility to their body parts

    Low-Energy Physics in Neutrino LArTPCs

    Get PDF
    In this white paper, we outline some of the scientific opportunities and challenges related to detection and reconstruction of low-energy (less than 100 MeV) signatures in liquid argon time-projection chamber (LArTPC) detectors. Key takeaways are summarized as follows. 1) LArTPCs have unique sensitivity to a range of physics and astrophysics signatures via detection of event features at and below the few tens of MeV range. 2) Low-energy signatures are an integral part of GeV-scale accelerator neutrino interaction final states, and their reconstruction can enhance the oscillation physics sensitivities of LArTPC experiments. 3) BSM signals from accelerator and natural sources also generate diverse signatures in the low-energy range, and reconstruction of these signatures can increase the breadth of BSM scenarios accessible in LArTPC-based searches. 4) Neutrino interaction cross sections and other nuclear physics processes in argon relevant to sub-hundred-MeV LArTPC signatures are poorly understood. Improved theory and experimental measurements are needed. Pion decay-at-rest sources and charged particle and neutron test beams are ideal facilities for experimentally improving this understanding. 5) There are specific calibration needs in the low-energy range, as well as specific needs for control and understanding of radiological and cosmogenic backgrounds. 6) Novel ideas for future LArTPC technology that enhance low-energy capabilities should be explored. These include novel charge enhancement and readout systems, enhanced photon detection, low radioactivity argon, and xenon doping. 7) Low-energy signatures, whether steady-state or part of a supernova burst or larger GeV-scale event topology, have specific triggering, DAQ and reconstruction requirements that must be addressed outside the scope of conventional GeV-scale data collection and analysis pathways

    Identification and reconstruction of low-energy electrons in the ProtoDUNE-SP detector

    Full text link
    Measurements of electrons from Îœe\nu_e interactions are crucial for the Deep Underground Neutrino Experiment (DUNE) neutrino oscillation program, as well as searches for physics beyond the standard model, supernova neutrino detection, and solar neutrino measurements. This article describes the selection and reconstruction of low-energy (Michel) electrons in the ProtoDUNE-SP detector. ProtoDUNE-SP is one of the prototypes for the DUNE far detector, built and operated at CERN as a charged particle test beam experiment. A sample of low-energy electrons produced by the decay of cosmic muons is selected with a purity of 95%. This sample is used to calibrate the low-energy electron energy scale with two techniques. An electron energy calibration based on a cosmic ray muon sample uses calibration constants derived from measured and simulated cosmic ray muon events. Another calibration technique makes use of the theoretically well-understood Michel electron energy spectrum to convert reconstructed charge to electron energy. In addition, the effects of detector response to low-energy electron energy scale and its resolution including readout electronics threshold effects are quantified. Finally, the relation between the theoretical and reconstructed low-energy electron energy spectrum is derived and the energy resolution is characterized. The low-energy electron selection presented here accounts for about 75% of the total electron deposited energy. After the addition of lost energy using a Monte Carlo simulation, the energy resolution improves from about 40% to 25% at 50~MeV. These results are used to validate the expected capabilities of the DUNE far detector to reconstruct low-energy electrons.Comment: 19 pages, 10 figure

    Impact of cross-section uncertainties on supernova neutrino spectral parameter fitting in the Deep Underground Neutrino Experiment

    Get PDF
    A primary goal of the upcoming Deep Underground Neutrino Experiment (DUNE) is to measure the O(10)\mathcal{O}(10) MeV neutrinos produced by a Galactic core-collapse supernova if one should occur during the lifetime of the experiment. The liquid-argon-based detectors planned for DUNE are expected to be uniquely sensitive to the Îœe\nu_e component of the supernova flux, enabling a wide variety of physics and astrophysics measurements. A key requirement for a correct interpretation of these measurements is a good understanding of the energy-dependent total cross section σ(EÎœ)\sigma(E_\nu) for charged-current Îœe\nu_e absorption on argon. In the context of a simulated extraction of supernova Îœe\nu_e spectral parameters from a toy analysis, we investigate the impact of σ(EÎœ)\sigma(E_\nu) modeling uncertainties on DUNE's supernova neutrino physics sensitivity for the first time. We find that the currently large theoretical uncertainties on σ(EÎœ)\sigma(E_\nu) must be substantially reduced before the Îœe\nu_e flux parameters can be extracted reliably: in the absence of external constraints, a measurement of the integrated neutrino luminosity with less than 10\% bias with DUNE requires σ(EÎœ)\sigma(E_\nu) to be known to about 5%. The neutrino spectral shape parameters can be known to better than 10% for a 20% uncertainty on the cross-section scale, although they will be sensitive to uncertainties on the shape of σ(EÎœ)\sigma(E_\nu). A direct measurement of low-energy Îœe\nu_e-argon scattering would be invaluable for improving the theoretical precision to the needed level.Comment: 25 pages, 21 figure

    Identification and reconstruction of low-energy electrons in the ProtoDUNE-SP detector

    Get PDF
    Measurements of electrons from Îœe interactions are crucial for the Deep Underground Neutrino Experiment (DUNE) neutrino oscillation program, as well as searches for physics beyond the standard model, supernova neutrino detection, and solar neutrino measurements. This article describes the selection and reconstruction of low-energy (Michel) electrons in the ProtoDUNE-SP detector. ProtoDUNE-SP is one of the prototypes for the DUNE far detector, built and operated at CERN as a charged particle test beam experiment. A sample of low-energy electrons produced by the decay of cosmic muons is selected with a purity of 95%. This sample is used to calibrate the low-energy electron energy scale with two techniques. An electron energy calibration based on a cosmic ray muon sample uses calibration constants derived from measured and simulated cosmic ray muon events. Another calibration technique makes use of the theoretically well-understood Michel electron energy spectrum to convert reconstructed charge to electron energy. In addition, the effects of detector response to low-energy electron energy scale and its resolution including readout electronics threshold effects are quantified. Finally, the relation between the theoretical and reconstructed low-energy electron energy spectra is derived, and the energy resolution is characterized. The low-energy electron selection presented here accounts for about 75% of the total electron deposited energy. After the addition of lost energy using a Monte Carlo simulation, the energy resolution improves from about 40% to 25% at 50 MeV. These results are used to validate the expected capabilities of the DUNE far detector to reconstruct low-energy electrons
    • 

    corecore