1,955 research outputs found

    A family of pseudo-Anosov braids with large conjugacy invariant sets

    Full text link
    We show that there is a family of pseudo-Anosov braids independently parameterized by the braid index and the (canonical) length whose smallest conjugacy invariant sets grow exponentially in the braid index and linearly in the length and conclude that the conjugacy problem remains exponential in the braid index under the current knowledge.Comment: 16 pages, 6 figure

    A family of representations of braid groups on surfaces

    Full text link
    We propose a family of new representations of the braid groups on surfaces that extend linear representations of the braid groups on a disc such as the Burau representation and the Lawrence-Krammer-Bigelow representation.Comment: 21 pages, 4 figure

    Asymmetric ephaptic inhibition between compartmentalized olfactory receptor neurons.

    Get PDF
    In the Drosophila antenna, different subtypes of olfactory receptor neurons (ORNs) housed in the same sensory hair (sensillum) can inhibit each other non-synaptically. However, the mechanisms underlying this underexplored form of lateral inhibition remain unclear. Here we use recordings from pairs of sensilla impaled by the same tungsten electrode to demonstrate that direct electrical ("ephaptic") interactions mediate lateral inhibition between ORNs. Intriguingly, within individual sensilla, we find that ephaptic lateral inhibition is asymmetric such that one ORN exerts greater influence onto its neighbor. Serial block-face scanning electron microscopy of genetically identified ORNs and circuit modeling indicate that asymmetric lateral inhibition reflects a surprisingly simple mechanism: the physically larger ORN in a pair corresponds to the dominant neuron in ephaptic interactions. Thus, morphometric differences between compartmentalized ORNs account for highly specialized inhibitory interactions that govern information processing at the earliest stages of olfactory coding

    Localizing Gravitational Wave Sources with Single-Baseline Atom Interferometers

    Full text link
    Localizing sources on the sky is crucial for realizing the full potential of gravitational waves for astronomy, astrophysics, and cosmology. We show that the mid-frequency band, roughly 0.03 to 10 Hz, has significant potential for angular localization. The angular location is measured through the changing Doppler shift as the detector orbits the Sun. This band maximizes the effect since these are the highest frequencies in which sources live several months. Atom interferometer detectors can observe in the mid-frequency band, and even with just a single baseline can exploit this effect for sensitive angular localization. The single baseline orbits around the Earth and the Sun, causing it to reorient and change position significantly during the lifetime of the source, and making it similar to having multiple baselines/detectors. For example, atomic detectors could predict the location of upcoming black hole or neutron star merger events with sufficient accuracy to allow optical and other electromagnetic telescopes to observe these events simultaneously. Thus, mid-band atomic detectors are complementary to other gravitational wave detectors and will help complete the observation of a broad range of the gravitational spectrum.Comment: 16 pages, 3 figures, 2 table

    A Feasible Configuration of AFDX Networks for Real-Time Flows in Avionics Systems

    Get PDF
    REACTION 2013. 2nd International Workshop on Real-time and distributed computing in emerging applications. December 3rd, 2013, Vancouver, Canada.AFDX (Avionics Full Duplex Switched Ethernet) Networks have been proposed to meet unique ADN (Aircraft Data Networks) characteristics and then standardized as a Part 7 in ARNIC 664. As for this new communication technology, some research works have been conducted to address design issues such as optimizing virtual links as well as analytic modeling including response time. Despite of their research efforts, configuration problem for both MTU (Maximum Transmission Unit) and BAG (Bandwidth Allocation Gap) over virtual links in AFDX networks remains unsolved yet. In this paper, we propose how to set MTU and BAG value on each virtual link according to both application requirements and AFDX switch constraints. We define a new problem of feasible configurations of virtual links in an AFDX switch and propose an algorithm to derive feasible BAG and MTU pairs based on the branch-and-bound technique. Throughout simulations, we evaluate the proposed algorithm and analyze the effect of parameters in AFDX networks.This research was supported by Basic Science Research Program through the National Research Foundation of Korea (NRF) funded by the Ministry of Education (No. NRF- 2012R1A1A1015096) and BK21+ Program

    Static fluid magnetic resonance urography in evaluation of ureteral ectopia: Experience in 10 pediatric cases

    Get PDF
    Introduction: Ectopic ureters are often very difficult to diagnose with conventional imaging modalities especially in children. Magnetic resonance urography (MRU) has been recently investigated as a problem-solving tool for the evaluation of various congenital urogenital anomalies with favorable results.Aim of the work: To assess the value of static fluid MRU in diagnosing ectopic ureters in childhood.Patientsand methods: Ten out of 14 pediatric patients with suspected ureteral ectopia (as suggested by clinical or conventional imaging techniques) were included in this study and prospectively studied by MRUaiming to confirmthe suspected diagnosis. The examinations were done on 1.5T machines using static fluid T2W-MRU sequences. Ultrasound examinations were done for all patients. Voiding cystourethrogram (VCUG) was done for 8 patients to exclude vesico-ureteric reflux or urethral anomalies.Results: All studied patients had dilated collecting systems. Static fluid MRU was able to detect the site of ectopic ureteric insertion in all 10 patients. It was superior to ultrasound in evaluation of 8 cases with complex duplex systems. In one patient with multiple congenital anomalies, MRU clearly demonstrated the urinary and extra-urinary anomalies. The final diagnosis was confirmed by surgical or endoscopic data in all patients.Conclusions: In dilated collecting systems, static fluid MRU can provide detailed assessment of the collecting systems and ureters as well as adequately detect ureteral ectopia. MRU should be recommended whenever a ureteric insertion anomaly is suspected.Keywords: Magnetic resonance urography; MRU; Ectopic ureter; Ureteral ectopia; Ureteric insertion anomalie

    Examining the Validity of Fitbit Charge HR \u3csup\u3eTM\u3c/sup\u3e for Measuring Heart Rate in Free-Living Conditions

    Get PDF
    Optical blood flow sensors (i.e. photoplethysmographic techniques) have recently been utilized in wearable activity trackers. The Fitbit Charge HRTM (FBHR) is one of the widely recognized wearable activity trackers that utilizes Fitbit’s proprietary PurePulse optical heart rate (HR) technology to automatically measure wrist-based HR. Despite its increasing popularity, however, no study to date has addressed the validity of FBHR for measuring HR in free-living conditions. PURPOSE: The purpose of this study was to examine the validity of FBHR for measuring HR using a chest strap Polar HR monitor (PHR) as a reference measure in free-living conditions. METHODS: Ten healthy college students (8 males; mean age = 26.5 ±5.4 years; mean body mass index (BMI) = 24.5 ±3.23 kg·m2) participated in the study. The participants were asked to perform normal daily activities for 8 hours in a day while wearing the PHR (model RS400) on their chest and two FBHRs on their dominant and non-dominant wrists, respectively. HR was recorded every minute and the minute-by-minute HR data from each monitor were synchronized by time of day. Pearson correlation was used to examine the linearity of average beats-per-minute (bpm) estimated from FBHRs with respect to the PHR. Mean differences in average bpm between the monitors were examined by a general linear model for repeated measures. Lastly, mean absolute percentage error (MAPE) of minute-by-minute bpm estimated from the FBHRs were calculated against the PHR. RESULTS: Average HRs (mean ±SD) for PHR, FBHR non-dominant, and FBHR dominant were 75.6 ±18.5 bpm, 72.8 ±16.7 bpm, and 73.9 ±17.06 bpm, respectively. Pearson correlation coefficients (r) between the PHR and FBHR non-dominant and dominant were r=.805 and r=.793, respectively. MAPE were 9.17 ±10.9% for FBHR non-dominant and 9.71 ± 12.4% for FBHR HR dominant. ANOVA and post-hoc analyses with Bonferroni revealed significant differences in estimating HR from FBHR non-dominant wrist (p=.001) and FBHR dominant wrist (p=.001) compared to PHR monitor. CONCLUSION: The results indicated that the wrist-oriented Fitbit Charge HRTM device does not provide an accurate measurement of HR during free-living condition in this study. However, further research is needed to validate these monitors with a larger sample with different population groups. Optical blood flow sensors (i.e. photoplethysmographic techniques) have recently been utilized in wearable activitytrackers. The Fitbit Charge HRTM (FBHR) is one of the widely recognized wearable activity trackers that utilizesFitbit’sproprietary PurePulse optical heart rate (HR) technology to automatically measure wrist-based HR. Despiteits increasing popularity, however, no study to date has addressed the validity of FBHR for measuring HR in free-living conditions. PURPOSE: The purpose of this study was to examine the validity of FBHR for measuring HRusing a chest strap Polar HR monitor (PHR) as a reference measure in free-living conditions. METHODS: Tenhealthy college students (8 males; mean age = 26.5 ±5.4 years; mean body mass index (BMI) = 24.5 ±3.23kg·m2) participated in the study. The participants were asked to perform normal daily activities for 8 hours in a daywhile wearing the PHR (model RS400) on their chest and two FBHRs on their dominant and non-dominant wrists,respectively. HR was recorded every minute and the minute-by-minute HR data from each monitor weresynchronized by time of day. Pearson correlation was used to examine the linearity of average beats-per-minute(bpm) estimated from FBHRs with respect to the PHR. Mean differences in average bpm between the monitorswere examined by a general linear model for repeated measures. Lastly, mean absolute percentage error (MAPE)of minute-by-minute bpm estimated from the FBHRs were calculated against the PHR. RESULTS: Average HRs(mean ±SD) for PHR, FBHR non-dominant, and FBHR dominant were 75.6 ±18.5 bpm, 72.8 ±16.7 bpm, and73.9 ±17.06 bpm, respectively. Pearson correlation coefficients (r) between the PHR and FBHR non-dominantand dominant were r=.805 and r=.793, respectively. MAPE were 9.17 ±10.9% for FBHR non-dominant and 9.71 ±12.4% for FBHR HR dominant. ANOVA and post-hoc analyses with Bonferroni revealed significant differences inestimating HR from FBHR non-dominant wrist (p=.001) and FBHR dominant wrist (p=.001) compared to PHRmonitor. CONCLUSION: The results indicated that the wrist-oriented Fitbit Charge HRTM device does not providean accurate measurement of HR during free-living condition in this study. However, further research is needed tovalidate these monitors with a larger sample with different population groups

    Reliability of DEXA on Body Composition in Korean Athletes

    Get PDF
    PURPOSE: The purpose of this study was to assess the reliability of DEXA for measuring body composition in Korean Athletes. METHODS: Twenty-nine athletes (n=29) registered for the college athlete program voluntarily participated in the study. Participants’ height and weight were measured, and BMI (Body Mass Index) was calculated before the participants’ body composition was measured. Muscle mass (kg), lean mass (kg), bone mineral density (BMC) (g·cm-2), and total fat mass (kg) of each participant was assessed by DEXA lunar DPX-L (GE Lunar, Madison, USA) for four times within a day to examine the difference by time frames. Four trials consist of ‘early in the morning × 2 with fasting’ with 30min break between two trials, ‘after lunch × 2’ with 30 min break between the two trials. Intra-class correlation (ICC) was conducted for overall reliability (p\u3c0.05) and a repeated measure ANOVA was performed to compare the difference of each trial (p\u3c0.05). RESULTS: The mean ± SD of muscle mass, lean mass, BMC, and fat mass was 56.4 ± 4.6kg, 59.4 ± 5.0kg, 2.3 ± 0.4g·cm-2, and 9.3 ± 4.8kg respectively. Each trail (mean ± SD) of muscle mass were 56.4 ± 4.7kg, 56.1 ± 4.8kg, 56.5 ± 4.6kg, and 56.4 ± 4.7kg, respectively, lean mass were 59.4 ± 5.1kg, 59.2 ± 5.1kg, 59.5 ± 5.0kg, and 59.4 ± 5.0kg, respectively, BMC were 3.0 ± 0.4g·cm-2, 3.0 ± 0.4g·cm-2, 3.0 ± 0.4g·cm- 2, and 3.0 ± 0.4g·cm-2, respectively, and fat mass were 9.3 ± 4.9kg, 9.2 ± 4.8kg, 9.3 ± 4.9kg, and 9.3 ± 4.9kg, respectively. Reliability of the ICC test showed strong agreement on muscle mass (r=0. 994 and p\u3c0.0001), lean mass (r=0. 995 and p\u3c0.0001), BMC (r=0. 995 and p\u3c0.0001), and fat mass (r=0. 998 and p\u3c0.0001). Cronbach’s alpha were 0.99 (muscle mass), 0.99 (Lean Mass), 0.99 (BMC), and 1.00 (Fat mass). No significant difference between each trial was observed in fat mass (p\u3e0.36). However, there was a significant difference in muscle mass (p\u3c0.001), lean mass (p\u3c0.001), and BMC (p\u3c0.04). CONCLUSION: Although all of the variables showed strong agreement on overall reliability from the ICC test, the reliability for the muscle mass, lean mass, and BMC showed significant differences in different time frame

    Exploration of better policies and programmes to improve socioeconomic status of hiv-affected individuals in nepal: a qualitative study.

    Get PDF
    The first case of HIV/AIDS in Nepal was reported in 1988. Since then, the HIV epidemic has moved from a ‘low prevalence’ to a ‘concentrated epidemic’ among injecting drug users, sex workers, and male labour migrants who travel between Nepal and India. Objectives of this study were to explore major problems faced by people living with HIV/AIDS (PLHIV); policy gaps, and recommendations of better policies and programmes to improve the current situation of PLHIV in Nepal. 18 in-depth interviews were conducted in Kathmandu in August 2016. A thematic analysis approach was applied to the information provided. Results of the study revealed that assistance provided to PLHIV by governmental, non-governmental and international organizations was limited. One-third of the participants reported that PLHIV could not continue their job, were not offered employment (33.3%), and they were removed from job by employers after finding out their HIV status (27.8%). One-third reported different types of stigma and discrimination towards PLHIV, including self-stigma. Over a fifth reported that children affected by HIV/ AIDS were discriminated in schools by teachers, fellow students, and school administrators. The study concludes that PLHIV are still facing a number of social and economic problems in Nepal. Although free treatment services are said to be available, they are not completely free. Stigma and discrimination are still highly prevalent in villages compared to cities, and among female compared to male PLHIV. Therefore, specific policies and programmes are recommended to relevant stakeholders to improve the socioeconomic status of PLHIV in Nepal

    Tuning of undoped ZnO thin film via plasma enhanced atomic layer deposition and its application for an inverted polymer solar cell

    Get PDF
    We studied the tuning of structural and optical properties of ZnO thin film and its correlation to the efficiency of inverted solar cell using plasma-enhanced atomic layer deposition (PEALD). The sequential injection of DEZn and O2 plasma was employed for the plasma-enhanced atomic layer deposition of ZnO thin film. As the growth temperature of ZnO film was increased from 100 ??C to 300??C, the crystallinity of ZnO film was improved from amorphous to highly ordered (002) direction ploy-crystal due to self crystallization. Increasing oxygen plasma time in PEALD process also introduces growing of hexagonal wurtzite phase of ZnO nanocrystal. Excess of oxygen plasma time induces enhanced deep level emission band (500 ??? 700 nm) in photoluminescence due to Zn vacancies and other defects. The evolution of structural and optical properties of PEALD ZnO films also involves in change of electrical conductivity by 3 orders of magnitude. The highly tunable PEALD ZnO thin films were employed as the electron conductive layers in inverted polymer solar cells. Our study indicates that both structural and optical properties rather than electrical conductivities of ZnO films play more important role for the effective charge collection in photovoltaic device operation. The ability to tune the materials properties of undoped ZnO films via PEALD should extend their functionality over the wide range of advanced electronic applications.open2
    corecore