627 research outputs found

    Finite Size and Current Effects on IV Characteristics of Josephson Junction Arrays

    Full text link
    The effects of finite size and of finite current on the current-voltage characteristics of Josephson junction arrays is studied both theoretically and by numerical simulations. The cross-over from non-linear to linear behavior at low temperature is shown to be a finite size effect and the non-linear behavior at higher temperature, T>TKTT>T_{KT}, is shown to be a finite current effect. These are argued to result from competition between the three length scales characterizing the system. The importance of boundary effects is discussed and it is shown that these may dominate the behavior in small arrays.Comment: 5 pages, figures included, to appear in PR

    Analysis and spectral characteristics of a spread-spectrum technique for conducted EMI suppression

    Full text link

    Theoretical study of the absorption spectra of the sodium dimer

    Full text link
    Absorption of radiation from the sodium dimer molecular states correlating to Na(3s)-Na(3s) is investigated theoretically. Vibrational bound and continuum transitions from the singlet X Sigma-g+ state to the first excited singlet A Sigma-u+ and singlet B Pi-u states and from the triplet a Sigma-u+ state to the first excited triplet b Sigma-g+ and triplet c Pi-g states are studied quantum-mechanically. Theoretical and experimental data are used to characterize the molecular properties taking advantage of knowledge recently obtained from ab initio calculations, spectroscopy, and ultra-cold atom collision studies. The quantum-mechanical calculations are carried out for temperatures in the range from 500 to 3000 K and are compared with previous calculations and measurements where available.Comment: 19 pages, 8 figures, revtex, eps

    Exotic Meson Production in the f1(1285)πf_{1}(1285)\pi^{-} System observed in the Reaction πpηπ+ππp\pi^{-} p \to \eta\pi^{+}\pi^{-}\pi^{-} p at 18 GeV/c

    Get PDF
    This letter reports results from the partial wave analysis of the πππ+η\pi^{-}\pi^{-}\pi^{+}\eta final state in πp\pi^{-}p collisions at 18GeV/c. Strong evidence is observed for production of two mesons with exotic quantum numbers of spin, parity and charge conjugation, JPC=1+J^{PC} = 1^{-+} in the decay channel f1(1285)πf_{1}(1285)\pi^{-}. The mass M=1709±24±41M = 1709 \pm 24 \pm 41 MeV/c^2 and width Γ=403±80±115\Gamma = 403 \pm 80 \pm 115 MeV/c^2 of the first state are consistent with the parameters of the previously observed π1(1600)\pi_{1}(1600). The second resonance with mass M=2001±30±92M = 2001 \pm 30 \pm 92 MeV/c^2 and width Γ=333±52±49\Gamma = 333 \pm 52 \pm 49 MeV/c^2 agrees very well with predictions from theoretical models. In addition, the presence of π2(1900)\pi_{2}(1900) is confirmed with mass M=2003±88±148M = 2003 \pm 88 \pm 148 MeV/c^2 and width Γ=306±132±121\Gamma = 306 \pm 132 \pm 121 MeV/c^2 and a new state, a1(2096)a_{1}(2096), is observed with mass M=2096±17±121M = 2096 \pm 17 \pm 121 MeV/c^2 and width Γ=451±41±81\Gamma = 451 \pm 41 \pm 81 MeV/c^2. The decay properties of these last two states are consistent with flux tube model predictions for hybrid mesons with non-exotic quantum numbers

    Domain Walls Motion and Resistivity in a Fully-Frustrated Josephson Array

    Full text link
    It is identified numerically that the resistivity of a fully-frustrated Josephson-junction array is due to motion of domain walls in vortex lattice rather than to motion of single vortices

    Confirmation of a pi_1^0 Exotic Meson in the \eta \pi^0 System

    Full text link
    The exclusive reaction πpηπ0n\pi^- p \to \eta \pi^0 n, ηπ+ππ0\eta \to \pi^+ \pi^- \pi^0 at 18 GeV/c/c has been studied with a partial wave analysis on a sample of 23~492 ηπ0n\eta \pi^0 n events from BNL experiment E852. A mass-dependent fit is consistent with a resonant hypothesis for the P+P_+ wave, thus providing evidence for a neutral exotic meson with JPC=1+J^{PC} = 1^{-+}, a mass of 1257±20±251257 \pm 20 \pm 25 MeV/c2/c^2, and a width of 354±64±60354 \pm 64 \pm 60 MeV/c2/c^2. New interpretations of the meson exotics in neutral ηπ0\eta \pi^0 system observed in E852 and Crystal Barrel experiments are discussed.Comment: p3, rewording the paragraph (at the bottom) about the phase variations. p4, rewording paragrath "The second method ..." . p4, at the bottom of paragrath "The third method ..." added consistent with the results of methods 1 and 2

    Observational Constraints on Teleparallel Dark Energy

    Full text link
    We use data from Type Ia Supernovae (SNIa), Baryon Acoustic Oscillations (BAO), and Cosmic Microwave Background (CMB) observations to constrain the recently proposed teleparallel dark energy scenario based on the teleparallel equivalent of General Relativity, in which one adds a canonical scalar field, allowing also for a nonminimal coupling with gravity. Using the power-law, the exponential and the inverse hyperbolic cosine potential ansatzes, we show that the scenario is compatible with observations. In particular, the data favor a nonminimal coupling, and although the scalar field is canonical the model can describe both the quintessence and phantom regimes.Comment: 19 pages, 6 figures, version accepted by JCA

    Low-dose CT for quantitative analysis in acute respiratory distress syndrome

    Get PDF
    Introduction: The clinical use of serial quantitative computed tomography (CT) to characterize lung disease and guide the optimization of mechanical ventilation in patients with acute respiratory distress syndrome (ARDS) is limited by the risk of cumulative radiation exposure and by the difficulties and risks related to transferring patients to the CT room. We evaluated the effects of tube current-time product (mAs) variations on quantitative results in healthy lungs and in experimental ARDS in order to support the use of low-dose CT for quantitative analysis. Methods: In 14 sheep chest CT was performed at baseline and after the induction of ARDS via intravenous oleic acid injection. For each CT session, two consecutive scans were obtained applying two different mAs: 60 mAs was paired with 140, 15 or 7.5 mAs. All other CT parameters were kept unaltered (tube voltage 120 kVp, collimation 32x0.5 mm, pitch 0.85, matrix 512x512, pixel size 0.625x0.625 mm ). Quantitative results obtained at different mAs were compared via Bland-Altman analysis. Results: Good agreement was observed between 60 mAs and 140 mAs and between 60 mAs and 15 mAs (all biases less than 1%). A further reduction of mAs to 7.5 mAs caused an increase in the bias of poorly and non aerated tissue (-2.9 and 2.4%, respectively) and determined a significant widening of the limits of agreement for the same compartments (-10.5 - 4.8 % for poorly aerated and -5.9 - 10.8% for non aerated tissue). Estimated mean effective dose at 140, 60, 15 and 7.5 mAs corresponded to 17.8, 7.4, 2.0 and 0.9 millisievert, respectively. Image noise of scans performed at 140, 60, 15 and 7.5 mAs corresponded to 10, 16, 38 and 74 Hounsfield Units, respectively. Conclusions: A reduction of effective dose up to 70% has been achieved with minimal effects on lung quantitative results. Low-dose computed tomography provides accurate quantitative results and could be used to characterize lung compartment distribution and possibly monitor time-course of ARDS with a lower risk of exposure to ionizing radiation. A further radiation dose reduction is associated with lower accuracy in quantitative results
    corecore