184 research outputs found

    Utilization of Multiyear Plant Breeding Data to Better Predict Genotype Performance

    Get PDF
    Despite the availability of multiyear, multicycle, and multiphase data in plant breeding programs for annual crops, selection is often based on single-year, single-cycle, and single-phase data. As genotypes in the same fields are usually grown under the same management practice, data from these fields can and should be analyzed together. In Monsanto’s North American maize (Zea mays L.) breeding program, this approach enables a spatial model to be fitted in each field, providing an estimate of spatial trend and a better estimate of residual variance in each field. Multiyear, multicycle analysis showed that the estimates of genotype × year variance (VGY) and genotype × year × location variance (VGYL) were still the largest components of the estimated phenotypic variance. Analysis of any single-year subset of the data inflated the estimate of genotypic variance (VG) by the size of the estimate of VGY, resulting in potential bias in the estimates of genotype performance. These results demonstrate the advantage of a combined analysis of data across years and cycles to make selection decisions for genotype advancement

    Author Correction: Long-term field comparison of multiple low-cost particulate matter sensors in an outdoor urban environment

    Get PDF
    Correction to: Scientific Reports https://doi.org/10.1038/s41598-019-43716-3, published online 16 May 2019. This Article contains a typographical error in the Acknowledgements section. “Natural Environmental Research Council grant number [NE/L002531/1]” should read: “Natural Environment Research Council: NE/N012070/1”

    ggstThe role of tendon microcirculation in Achilles and patellar tendinopathy

    Get PDF
    Tendinopathy is of distinct interest as it describes a painful tendon disease with local tenderness, swelling and pain associated with sonographic features such as hypoechogenic texture and diameter enlargement. Recent research elucidated microcirculatory changes in tendinopathy using laser Doppler flowmetry and spectrophotometry such as at the Achilles tendon, the patellar tendon as well as at the elbow and the wrist level. Tendon capillary blood flow is increased at the point of pain. Tendon oxygen saturation as well as tendon postcapillary venous filling pressures, determined non-invasively using combined Laser Doppler flowmetry and spectrophotometry, can quantify, in real-time, how tendon microcirculation changes over with pathology or in response to a given therapy. Tendon oxygen saturation can be increased by repetitive, intermittent short-term ice applications in Achilles tendons; this corresponds to 'ischemic preconditioning', a method used to train tissue to sustain ischemic damage. On the other hand, decreasing tendon oxygenation may reflect local acidosis and deteriorating tendon metabolism. Painful eccentric training, a common therapy for Achilles, patellar, supraspinatus and wrist tendinopathy decreases abnormal capillary tendon flow without compromising local tendon oxygenation. Combining an Achilles pneumatic wrap with eccentric training changes tendon microcirculation in a different way than does eccentric training alone; both approaches reduce pain in Achilles tendinopathy. The microcirculatory effects of measures such as extracorporeal shock wave therapy as well as topical nitroglycerine application are to be studied in tendinopathy as well as the critical question of dosage and maintenance. Interestingly it seems that injection therapy using color Doppler for targeting the area of neovascularisation yields to good clinical results with polidocanol sclerosing therapy, but also with a combination of epinephrine and lidocaine

    Testing Smart City environmental monitoring technology using small scale temporary cities

    Get PDF
    Exposure to Particulate Matter (PM) has been identified as a major health problem worldwide. Established measurement techniques require equipment costing many thousands of dollars and specialist expertise to maintain. Ongoing research is investigating the use of low cost <;$300 sensors to enable greater temporal-spatial density of readings to be taken. There are questions about the suitability and reliability of these low-cost sensors, which can be addressed by deploying and evaluating the sensors in real world applications. Rather than deploying standalone data loggers for each sensor, each air quality monitor is connected to an IoT device to enable real time transmission of data. We propose festival sites as small scale cities to enable a short term deployments and evaluation of sensors. This work illustrates that, if coupled with higher resolution of wind data, low-cost sensors may enable to follow the evolution of pollution hotspots and help the identification of pollution sources. This study, building upon the body of work focused on the evaluation and best practice of using low-cost sensors for PM monitoring. We present data from these IoT devices and experiences gained from using a festival site as a substitute for a city

    An investigation into the depth of penetration of low level laser therapy through the equine tendon in vivo

    Get PDF
    Low level laser therapy (LLLT) is frequently used in the treatment of wounds, soft tissue injury and in pain management. The exact penetration depth of LLLT in human tissue remains unspecified. Similar uncertainty regarding penetration depth arises in treating animals. This study was designed to test the hypothesis that transmission of LLLT in horses is increased by clipping the hair and/or by cleaning the area to be treated with alcohol, but is unaffected by coat colour. A LLLT probe (810 nm, 500 mW) was applied to the medial aspect of the superficial flexor tendon of seventeen equine forelimbs in vivo. A light sensor was applied to the lateral aspect, directly opposite the laser probe to measure the amount of light transmitted. Light transmission was not affected by individual horse, coat colour or leg. However, it was associated with leg condition (F = 4.42, p = 0.0032). Tendons clipped dry and clipped and cleaned with alcohol, were both associated with greater transmission of light than the unprepared state. Use of alcohol without clipping was not associated with an increase in light transmission. These results suggest that, when applying laser to a subcutaneous structure in the horse, the area should be clipped and cleaned beforehand

    A systematic review with procedural assessments and meta-analysis of Low Level Laser Therapy in lateral elbow tendinopathy (tennis elbow)

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Recent reviews have indicated that low level level laser therapy (LLLT) is ineffective in lateral elbow tendinopathy (LET) without assessing validity of treatment procedures and doses or the influence of prior steroid injections.</p> <p>Methods</p> <p>Systematic review with meta-analysis, with primary outcome measures of pain relief and/or global improvement and subgroup analyses of methodological quality, wavelengths and treatment procedures.</p> <p>Results</p> <p>18 randomised placebo-controlled trials (RCTs) were identified with 13 RCTs (730 patients) meeting the criteria for meta-analysis. 12 RCTs satisfied half or more of the methodological criteria. Publication bias was detected by Egger's graphical test, which showed a negative direction of bias. Ten of the trials included patients with poor prognosis caused by failed steroid injections or other treatment failures, or long symptom duration or severe baseline pain. The weighted mean difference (WMD) for pain relief was 10.2 mm [95% CI: 3.0 to 17.5] and the RR for global improvement was 1.36 [1.16 to 1.60]. Trials which targeted acupuncture points reported negative results, as did trials with wavelengths 820, 830 and 1064 nm. In a subgroup of five trials with 904 nm lasers and one trial with 632 nm wavelength where the lateral elbow tendon insertions were directly irradiated, WMD for pain relief was 17.2 mm [95% CI: 8.5 to 25.9] and 14.0 mm [95% CI: 7.4 to 20.6] respectively, while RR for global pain improvement was only reported for 904 nm at 1.53 [95% CI: 1.28 to 1.83]. LLLT doses in this subgroup ranged between 0.5 and 7.2 Joules. Secondary outcome measures of painfree grip strength, pain pressure threshold, sick leave and follow-up data from 3 to 8 weeks after the end of treatment, showed consistently significant results in favour of the same LLLT subgroup (p < 0.02). No serious side-effects were reported.</p> <p>Conclusion</p> <p>LLLT administered with optimal doses of 904 nm and possibly 632 nm wavelengths directly to the lateral elbow tendon insertions, seem to offer short-term pain relief and less disability in LET, both alone and in conjunction with an exercise regimen. This finding contradicts the conclusions of previous reviews which failed to assess treatment procedures, wavelengths and optimal doses.</p
    corecore