116 research outputs found

    Tribal community and the economic benefits of tourism development : the case of safari tourism in the Samburu region (Kenya)

    Get PDF

    Wybrane funkcje stymulatorów na przykładach zapisów EKG

    Get PDF

    Wybrane funkcje stymulatorów na przykładach zapisów EKG

    Get PDF

    Agglomeration and the National Park. A strained relation in African conditions – the case of Nairobi and Nairobi National Park

    Get PDF
    The article discusses selected relations between the agglomeration of Nairobi and the functioning of the Nairobi National Park located within its borders. The close attention was paid to the socio-economic and spatial development of Nairobi, which exerts pressure on the ecosystem of the park. The spatial development (sprawl) of the city and blocking the migration corridors of mammals leading to the areas outside the park were listed among the main factors of anthropopression. The city development needs raise the question about the future of the Nairobi NP, which in fact is strictly dependent on the political decisions on national level.W artykule omówiono wybrane relacje między rozwojem aglomeracji Nairobi a funkcjonowaniem położonego w jej granicach Parku Narodowego Nairobi. Zwrócono szczególną uwagę na rozwój społeczno-ekonomiczny i przestrzenny Nairobi, który wywiera coraz silniejszą presję na ekosystem parku. Wśród głównych czynników antropopresji wymieniono przestrzenne rozlewanie się (sprawl) miasta oraz blokowanie korytarzy migracji ssaków na tereny poza parkiem. Potrzeby rozwojowe miasta stawiają pod znakiem zapytania przyszłość PN Nairobi, która w znacznym stopniu jest uzależniona od decyzji politycznych władz krajowych

    Ablacja - fascynująca metoda usuwania arytmii

    Get PDF
    Ablacja oznacza celowe uszkodzenie tkanek za pomocą czynników fizycznych lub chemicznych. W okulistyce, laryngologii, onkologii, ginekologii, gastroenterologii stosuje się różne metody prowadzące do zaplanowanego uszkodzenia tkanek: światło laserowe, energia mikrofal, miejscowe zamrażanie tkanek (krioablacja), substancje chemiczne (alkohol). W chorobach serca stosuje się najczęściej ablację prądem o częstotliwości radiowej. Zmienny prąd elektryczny o częstotliwości radiowej (RF) przepływający między końcówką elektrody umieszczonej w sercu oraz elastyczną płytką „prądu rozproszenia” na powierzchni ciała pacjenta powoduje wzrost temperatury w miejscu stykania się elektrody wewnątrzsercowej z tkanką. Obszar uszkodzenia zależy od wartości temperatury na granicy między elektrodą i powierzchnią uszkadzanej tkanki. Maksymalny obszar uszkodzenia tkanek jest określony dla danej elektrody. Zależy on od jej wielkości i kształtu. Chociaż zasadniczym czynnikiem uszkodzenia jest ciepło, to nie wyjaśniono wpływu zmiennego pola elektromagnetycznego na uszkodzenie komórek. Często obserwuje się ustąpienie przewodzenia przez dodatkowy szlak w pierwszych sekundach przepływu prądu RF, zanim nastąpi uszkodzenie tkanek ciepłem. W pierwszych godzinach po ablacji w miejscu przepływu prądu wsierdzie jest odkształcone i przykleja się do niego włóknik. Tworzy się ograniczony obszar martwicy. Powierzchnia obszaru uszkodzonego w czasie aplikacji prądu RF przekracza o około 1 mm linię styku elektrody z tkanką, zaś uszkodzenie może osiągać głębokość 7 mm. Ablacja z użyciem prądu o częstotliwości radiowej stała się metodą z wyboru leczenia zaburzeń rytmu serca, w tym również migotania przedsionków

    Characteristics of patients with newly diagnosed hematological malignancies referred for echocardiography

    Get PDF
    ObjectiveThe importance of cardio-hemato-oncology programs is increasing. The main aim of the study was to identify all coexisting cardiovascular disorders in patients with new hematological malignancies referred for echocardiography during baseline evaluation before anticancer therapy.Material and methodsThe study was based on 900 echocardiographic examinations performed within 12 months at the Institute of Hematology and Transfusion Medicine in Poland: 669 tests (74.3%) were dedicated to hemato-oncology patients at the different stages of cancer therapy, however almost a third of the tests (277, 30.8%) were part of a baseline evaluation before starting first line anticancer therapy due to newly diagnosed hematological malignancies.ResultsThe group of 277 patients with new hematological malignancies (138 women, 49.82%) with a median age of 66 years (interquartile range: 53-72 years) was included in the main analyses. The three most frequent new histopathological diagnoses were: non-Hodgkin lymphoma (63 cases; 22.74%), acute myeloid leukaemia (47 cases; 16.97%), and multiple myeloma (45 cases; 16.25%). The three most common clinical cardiology disorders were arterial hypertension (in 133 patients, 48.01%), arrhythmias (48 patients, 17.33%), and heart failure (39 patients, 14.08%). Among 48 patients with arrhythmias there were 22 cases with atrial fibrillation. The most frequently detected echocardiographic abnormality was Left Atrial Volume Index >34 ml/m2 which was present in 108 of 277 patients (38.99%) and associated with a significantly greater chance of concomitant diagnosis of arrhythmias (OR=1.98; p=0.048) especially atrial fibrillation (OR=3.39; p=0.025). The second most common echocardiographic finding was diastolic dysfunction 2nd or 3rd degree revealed in 43 patients (15.52%) and associated with a greater chance of simultaneous diagnosis of heart failure (OR=8.32; p<0.0001) or arrhythmias (OR=4.44; p<0.0001) including atrial fibrillation (OR=5.40; p=0.0003).ConclusionsIn patients with newly diagnosed hematological malignancies left ventricular diastolic dysfunction is a common abnormality in echocardiography and may determine diagnoses of heart failure or arrhythmias

    Clinical application of intracardiac echocardiography in the ablation of atrial fibrillation

    Get PDF
    Background: The application of intracardiac echocardiography (ICE) in atrial fibrillation (AF) ablation may increase the success rate and decrease the complication rate of the procedure. We present our preliminary observations concerning the utility of ICE in AF ablation. Methods: In February and July 2004 we performed 6 radiofrequency (RF) ablations guided by ICE (EP Med Systems) in patients with atrial tachyarrhythmia. All patients had undergone at least three months of oral anticoagulation therapy before the procedure. For three days before ablation enoxaparin was administered. During each procedure the ICE catheter was placed in the right atrium. Transseptal puncture was guided by fluoroscopy and ICE imaging. After placement of the introducer in the left atrium a bolus of heparin (100 IU/kg) was administered followed by additional boluses (1000 IU/h). Electroanatomical isolation of the pulmonary vein ostia was performed with a 4 mm ablation catheter (RF energy was set at 50–55oC and 25–35 W). RF energy was titrated if microbubble formation was observed and delivery was immediately terminated when a brisk shower of bubbles was detected. Results: Transseptal puncture was performed at a typical location in all patients (atypical anatomy was not revealed by ICE). The microbubble effect was observed in all patients. In 1 patient the effect was observed despite a power reduction and the RF application had to be terminated. The following short (15-20 s) applications were performed with low RF energy. During the same procedure ICE imaging revealed 2 thrombi (2 and 5 mm) on the Lasso electrode. None of the patients experienced thromboembolic complications. Conclusions: Intracardiac echocardiography is a useful imaging method in RF ablation. Low RF-energy and standard anticoagulation treatment do not prevent the microbubble effect and the formation of small thrombi

    Development of a user-adaptable human fall detection based on fall risk levels using depth sensor

    Get PDF
    Unintentional falls are a major public health concern for many communities, especially with aging populations. There are various approaches used to classify human activities for fall detection. Related studies have employed wearable, non-invasive sensors, video cameras and depth sensor-based approaches to develop such monitoring systems. The proposed approach in this study uses a depth sensor and employs a unique procedure which identifies the fall risk levels to adapt the algorithm for different people with their physical strength to withstand falls. The inclusion of the fall risk level identification, further enhanced and improved the accuracy of the fall detection. The experimental results showed promising performance in adapting the algorithm for people with different fall risk levels for fall detection
    corecore