98 research outputs found

    Reinforcing the role of the conventional C-arm - a novel method for simplified distal interlocking

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>The common practice for insertion of distal locking screws of intramedullary nails is a freehand technique under fluoroscopic control. The process is technically demanding, time-consuming and afflicted to considerable radiation exposure of the patient and the surgical personnel. A new concept is introduced utilizing information from within conventional radiographic images to help accurately guide the surgeon to place the interlocking bolt into the interlocking hole. The newly developed technique was compared to conventional freehand in an operating room (OR) like setting on human cadaveric lower legs in terms of operating time and radiation exposure.</p> <p>Methods</p> <p>The proposed concept (guided freehand), generally based on the freehand gold standard, additionally guides the surgeon by means of visible landmarks projected into the C-arm image. A computer program plans the correct drilling trajectory by processing the lens-shaped hole projections of the interlocking holes from a single image. Holes can be drilled by visually aligning the drill to the planned trajectory. Besides a conventional C-arm, no additional tracking or navigation equipment is required.</p> <p>Ten fresh frozen human below-knee specimens were instrumented with an Expert Tibial Nail (Synthes GmbH, Switzerland). The implants were distally locked by performing the newly proposed technique as well as the conventional freehand technique on each specimen. An orthopedic resident surgeon inserted four distal screws per procedure. Operating time, number of images and radiation time were recorded and statistically compared between interlocking techniques using non-parametric tests.</p> <p>Results</p> <p>A 58% reduction in number of taken images per screw was found for the guided freehand technique (7.4 ± 3.4) (mean ± SD) compared to the freehand technique (17.6 ± 10.3) (<it>p </it>< 0.001). Total radiation time (all 4 screws) was 55% lower for the guided freehand technique compared to conventional freehand (<it>p </it>= 0.001). Operating time per screw (from first shot to screw tightened) was on average 22% reduced by guided freehand (<it>p </it>= 0.018).</p> <p>Conclusions</p> <p>In an experimental setting, the newly developed guided freehand technique for distal interlocking has proven to markedly reduce radiation exposure when compared to the conventional freehand technique. The method utilizes established clinical workflows and does not require cost intensive add-on devices or extensive training. The underlying principle carries potential to assist implant positioning in numerous other applications within orthopedics and trauma from screw insertions to placement of plates, nails or prostheses.</p

    Comparison of risk-scoring systems in the prediction of outcome after liver resection

    Get PDF
    Background: Risk prediction techniques commonly used in liver surgery include the American Society of Anesthesiologists (ASA) grading, Charlson Comorbidity Index (CCI) and cardiopulmonary exercise tests (CPET). This study compares the utility of these techniques along with the number of segments resected as predictive tools in liver surgery. Methods: A review of a unit database of patients undergoing liver resection between February 2008 and January 2015 was undertaken. Patient demographics, ASA, CCI and CPET variables were recorded along with resection size. Clavien-Dindo grade III–V complications were used as a composite outcome in analyses. Association between predictive variables and outcome was assessed by univariate and multivariate techniques. Results: One hundred and seventy-two resections in 168 patients were identified. Grade III–V complications occurred after 42 (24.4%) liver resections. In univariate analysis of CPET variables, ventilatory equivalents for CO2 (VEqCO2) was associated with outcome. CCI score, but not ASA grade, was also associated with outcome. In multivariate analysis, the odds ratio of developing grade III–V complications for incremental increases in VEqCO2, CCI and number of liver segments resected were 1.09, 1.49 and 2.94, respectively. Conclusions: Of the techniques evaluated, resection size provides the simplest and most discriminating predictor of significant complications following liver surgery

    A novel framework for intelligent surveillance system based on abnormal human activity detection in academic environments

    Get PDF
    Abnormal activity detection plays a crucial role in surveillance applications, and a surveillance system thatcan perform robustly in an academic environment has become an urgent need. In this paper, we propose a novel framework for an automatic real-time video-based surveillance system which can simultaneously perform the tracking, semantic scene learning, and abnormality detection in an academic environment. To develop our system, we have divided the work into three phases: preprocessing phase, abnormal human activity detection phase, and content-based image retrieval phase. For motion object detection, we used the temporal-differencing algorithm and then located the motions region using the Gaussian function.Furthermore, the shape model based on OMEGA equation was used as a filter for the detected objects (i.e.,human and non-human). For object activities analysis, we evaluated and analyzed the human activities of the detected objects. We classified the human activities into two groups:normal activities and abnormal activities based on the support vector machine. The machine then provides an automatic warning in case of abnormal human activities. It also embeds a method to retrieve the detected object from the database for object recognition and identification using content-based image retrieval.Finally,a software-based simulation using MATLAB was performed and the results of the conducted experiments showed an excellent surveillance system that can simultaneously perform the tracking, semantic scene learning, and abnormality detection in an academic environment with no human intervention

    Management of colorectal cancer presenting with synchronous liver metastases

    Get PDF
    Up to a fifth of patients with colorectal cancer (CRC) present with synchronous hepatic metastases. In patients with CRC who present without intestinal obstruction or perforation and in whom comprehensive whole-body imaging confirms the absence of extrahepatic disease, evidence indicates a state of equipoise between several different management pathways, none of which has demonstrated superiority. Neoadjuvant systemic chemotherapy is advocated by current guidelines, but must be integrated with surgical management in order to remove the primary tumour and liver metastatic burden. Surgery for CRC with synchronous liver metastases can take a number of forms: the 'classic' approach, involving initial colorectal resection, interval chemotherapy and liver resection as the final step; simultaneous removal of the liver and bowel tumours with neoadjuvant or adjuvant chemotherapy; or a 'liver-first' approach (before or after systemic chemotherapy) with removal of the colorectal tumour as the final procedure. In patients with rectal primary tumours, the liver-first approach can potentially avoid rectal surgery in patients with a complete response to chemoradiotherapy. We overview the importance of precise nomenclature, the influence of clinical presentation on treatment options, and the need for accurate, up-to-date surgical terminology, staging tests and contemporary management options in CRC and synchronous hepatic metastatic disease, with an emphasis on multidisciplinary care

    Use of anticoagulants and antiplatelet agents in stable outpatients with coronary artery disease and atrial fibrillation. International CLARIFY registry

    Get PDF

    Impact of primary kidney disease on the effects of empagliflozin in patients with chronic kidney disease: secondary analyses of the EMPA-KIDNEY trial

    Get PDF
    Background: The EMPA KIDNEY trial showed that empagliflozin reduced the risk of the primary composite outcome of kidney disease progression or cardiovascular death in patients with chronic kidney disease mainly through slowing progression. We aimed to assess how effects of empagliflozin might differ by primary kidney disease across its broad population. Methods: EMPA-KIDNEY, a randomised, controlled, phase 3 trial, was conducted at 241 centres in eight countries (Canada, China, Germany, Italy, Japan, Malaysia, the UK, and the USA). Patients were eligible if their estimated glomerular filtration rate (eGFR) was 20 to less than 45 mL/min per 1·73 m2, or 45 to less than 90 mL/min per 1·73 m2 with a urinary albumin-to-creatinine ratio (uACR) of 200 mg/g or higher at screening. They were randomly assigned (1:1) to 10 mg oral empagliflozin once daily or matching placebo. Effects on kidney disease progression (defined as a sustained ≥40% eGFR decline from randomisation, end-stage kidney disease, a sustained eGFR below 10 mL/min per 1·73 m2, or death from kidney failure) were assessed using prespecified Cox models, and eGFR slope analyses used shared parameter models. Subgroup comparisons were performed by including relevant interaction terms in models. EMPA-KIDNEY is registered with ClinicalTrials.gov, NCT03594110. Findings: Between May 15, 2019, and April 16, 2021, 6609 participants were randomly assigned and followed up for a median of 2·0 years (IQR 1·5–2·4). Prespecified subgroupings by primary kidney disease included 2057 (31·1%) participants with diabetic kidney disease, 1669 (25·3%) with glomerular disease, 1445 (21·9%) with hypertensive or renovascular disease, and 1438 (21·8%) with other or unknown causes. Kidney disease progression occurred in 384 (11·6%) of 3304 patients in the empagliflozin group and 504 (15·2%) of 3305 patients in the placebo group (hazard ratio 0·71 [95% CI 0·62–0·81]), with no evidence that the relative effect size varied significantly by primary kidney disease (pheterogeneity=0·62). The between-group difference in chronic eGFR slopes (ie, from 2 months to final follow-up) was 1·37 mL/min per 1·73 m2 per year (95% CI 1·16–1·59), representing a 50% (42–58) reduction in the rate of chronic eGFR decline. This relative effect of empagliflozin on chronic eGFR slope was similar in analyses by different primary kidney diseases, including in explorations by type of glomerular disease and diabetes (p values for heterogeneity all &gt;0·1). Interpretation: In a broad range of patients with chronic kidney disease at risk of progression, including a wide range of non-diabetic causes of chronic kidney disease, empagliflozin reduced risk of kidney disease progression. Relative effect sizes were broadly similar irrespective of the cause of primary kidney disease, suggesting that SGLT2 inhibitors should be part of a standard of care to minimise risk of kidney failure in chronic kidney disease. Funding: Boehringer Ingelheim, Eli Lilly, and UK Medical Research Council

    Cuff inflation time significantly affects blood flow recorded with venous occlusion plethysmography

    Get PDF
    © 2019, The Author(s). Purpose: We tested whether the values of limb blood flow calculated with strain-gauge venous occlusion plethysmography (VOP) differ when venous occlusion is achieved by automated, or manual inflation, so providing rapid and slower inflation, respectively. Method: In 9 subjects (20–30 years), we calculated forearm blood flows (FBF) values at rest and following isometric handgrip at 70% maximum voluntary contraction (MVC) when rapid, or slower inflation was used. Result: Rapid and slower cuff inflation took 0.23 ± 0.01 (mean ± SEM) and 0.92 ± 0.02 s, respectively, reflecting the range reported in published studies. At rest, FBF calculated from the 1st cardiac cycle after rapid and slower inflation gave similar values: 10.5 ± 1.4 vs. 9.6 ± 1.3 ml dl − 1  min − 1 , respectively (P > 0.05). However, immediately post-contraction, FBF was ~ 40% lower with slower inflation: 54.6 ± 5.1 vs. 33.8 ± 4.2 ml dl − 1  min − 1 (P < 0.01). The latter value was similar to that calculated over the 3rd cardiac cycle following rapid inflation: 2nd cardiac cycle: 40.5 ± 4.5; 3rd cycle: 32.6 ± 4.5 ml dl − 1  min − 1 . Regression analyses of FBFs recorded at intervals post-contraction showed those calculated over the 1st, 2nd, or 3rd cardiac cycles with rapid inflation correlated well with those from the 1st cardiac cycle with manual inflation (r = 0.79, 0.82, 0.79; P < 0.01). However, only the slope for the 3rd cycle with rapid inflation vs. slower inflation was close to unity (2.07, 1.34, and 0.94, respectively). Conclusion: These findings confirm that the 1st cardiac cycle following venous occlusion should be used when calculating FBF using VOP and, but importantly, indicate that cuff inflation should be almost instantaneous; just ≥ 0.9 s leads to substantial underestimation, especially at high flows
    corecore