415 research outputs found

    Peeling fingers in an elastic Hele-Shaw channel

    Full text link
    Using experiments and a depth-averaged numerical model, we study instabilities of two-phase flows in a Hele-Shaw channel with an elastic upper boundary and a non-uniform cross-section prescribed by initial collapse. Experimentally, we find increasingly complex and unsteady modes of air-finger propagation as the dimensionless bubble speed, Ca, and level of collapse are increased, including pointed fingers, indented fingers and the feathered modes first identified by Cuttle et al.(J. Fluid Mech., vol. 886, 2020, A20). By introducing a measure of the viscous contribution to finger propagation, we identify a Ca threshold beyond which viscous forces are superseded by elastic effects. Quantitative prediction of this transition between 'viscous' and 'elastic' reopening regimes across levels of collapse establishes the fidelity of the numerical model. In the viscous regime, we recover the non-monotonic dependence on Ca of the finger pressure, which is characteristic of benchtop models of airway reopening. To explore the elastic regime numerically, we extend the depth-averaged model introduced by Fontana et al. (J. Fluid Mech., vol. 916, 2021, A27) to include an artificial disjoining pressure which prevents the unphysical self-intersection of the interface. Using time simulations, we capture for the first time the majority of experimental finger dynamics, including feathered modes. We show that these disordered states continually evolve, with no evidence of convergence to steady or periodic states. We find that the steady bifurcation structure satisfactorily predicts the bubble pressure as a function of Ca, but that it does not provide sufficient information to predict the transition to unsteady dynamics which appears strongly nonlinear.Comment: 28 pages, 15 figure

    The role of mixotrophic protists in the biological carbon pump

    Get PDF
    The traditional view of the planktonic food web describes consumption of inorganic nutrients by photoautotrophic phytoplankton, which in turn supports zooplankton and ultimately higher trophic levels. Pathways centred on bacteria provide mechanisms for nutrient recycling. This structure lies at the foundation of most models used to explore biogeochemical cycling, functioning of the biological pump, and the impact of climate change on these processes. We suggest an alternative new paradigm, which sees the bulk of the base of this food web supported by protist plankton communities that are mixotrophic – combining phototrophy and phagotrophy within a single cell. The photoautotrophic eukaryotic plankton and their heterotrophic microzooplankton grazers dominate only during the developmental phases of ecosystems (e.g. spring bloom in temperate systems). With their flexible nutrition, mixotrophic protists dominate in more-mature systems (e.g. temperate summer, established eutrophic systems and oligotrophic systems); the more-stable water columns suggested under climate change may also be expected to favour these mixotrophs. We explore how such a predominantly mixotrophic structure affects microbial trophic dynamics and the biological pump. The mixotroph-dominated structure differs fundamentally in its flow of energy and nutrients, with a shortened and potentially more efficient chain from nutrient regeneration to primary production. Furthermore, mixotrophy enables a direct conduit for the support of primary production from bacterial production. We show how the exclusion of an explicit mixotrophic component in studies of the pelagic microbial communities leads to a failure to capture the true dynamics of the carbon flow. In order to prevent a misinterpretation of the full implications of climate change upon biogeochemical cycling and the functioning of the biological pump, we recommend inclusion of multi-nutrient mixotroph models within ecosystem studies

    Muscle fiber conduction velocity is more affected after eccentric than concentric exercise

    No full text
    It has been shown that mean muscle fiber conduction velocity (CV) can be acutely impaired after eccentric exercise. However, it is not known whether this applies to other exercise modes. Therefore, the purpose of this experiment was to compare the effects of eccentric and concentric exercises on CV, and amplitude and frequency content of surface electromyography (sEMG) signals up to 24 h post-exercise. Multichannel sEMG signals were recorded from biceps brachii muscle of the exercised arm during isometric maximal voluntary contraction (MVC) and electrically evoked contractions induced by motor-point stimulation before, immediately after and 2 h after maximal eccentric (ECC group, N = 12) and concentric (CON group, N = 12) elbow flexor exercises. Isometric MVC decreased in CON by 21.7 ± 12.0% (± SD, p < 0.01) and by 30.0 ± 17.7% (p < 0.001) in ECC immediately post-exercise when compared to baseline. At 2 h post-exercise, ECC showed a reduction in isometric MVC by 24.7 ± 13.7% (p < 0.01) when compared to baseline, while no significant reduction (by 8.0 ± 17.0%, ns) was observed in CON. Similarly, reduction in CV was observed only in ECC both during the isometric MVC (from baseline of 4.16 ± 0.3 to 3.43 ± 0.4 m/s, p < 0.001) and the electrically evoked contractions (from baseline of 4.33 ± 0.4 to 3.82 ± 0.3 m/s, p < 0.001). In conclusion, eccentric exercise can induce a greater and more prolonged reduction in muscle force production capability and CV than concentric exercis

    Range of shoulder motion in patients with adhesive capsulitis; Intra-tester reproducibility is acceptable for group comparisons

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Measurements of range of motion play a key role in shoulder research. The purpose of this study is to investigate intra-observer reproducibility of measurements of active and passive range of motion in patients with adhesive capsulitis.</p> <p>Methods</p> <p>The study was carried out in a population consisting of 32 patients with clinical signs of adhesive capsulitis. A specified measurement protocol was used, and range of motion in affected and non-affected shoulders was measured twice for each patient with a one-week interval.</p> <p>Results</p> <p>For most of the investigated individual movements, test-retest differences in range of motion score of more than approximately 15° are not likely to occur as a result of measurement error only. Point-estimates for the intraclass correlation coefficient ranged from 0.61 to 0.93.</p> <p>Conclusion</p> <p>Range of motion of patients with adhesive capsulitis can be measured with acceptable reproducibility in settings where groups are compared. Scores for individual patients should be interpreted with caution.</p

    Hydrodilatation, corticosteroids and adhesive capsulitis: A randomized controlled trial

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Hydrodilatation of the glenohumeral joint is by several authors reported to improve shoulder pain and range of motion for patients with adhesive capsulitis. Procedures described often involve the injection of corticosteroids, to which the reported treatment effects may be attributed. Any important contribution arising from the hydrodilatation procedure itself remains to be demonstrated.</p> <p>Methods</p> <p>In this randomized trial, a hydrodilatation procedure including corticosteroids was compared with the injection of corticosteroids without dilatation. Patients were given three injections with two-week intervals, and all injections were given under fluoroscopic guidance. Outcome measures were the Shoulder Pain and Disability Index (SPADI) and measures of active and passive range of motion. Seventy-six patients were included and groups were compared six weeks after treatment. The study was designed as an open trial.</p> <p>Results</p> <p>The groups showed a rather similar degree of improvement from baseline. According to a multiple regression analysis, the effect of dilatation was a mean improvement of 3 points (confidence interval: -5 to 11) on the SPADI 0–100 scale. T-tests did not demonstrate any significant between-group differences in range of motion.</p> <p>Conclusion</p> <p>This study did not identify any important treatment effects resulting from three hydrodilatations that included steroid compared with three steroid injections alone.</p> <p>Trial registration</p> <p>The study is registered in Current Controlled Trials with the registration number ISRCTN90567697.</p
    • 

    corecore