98 research outputs found
Recommended from our members
Trauma and acute care surgeons report prescribing less opioids over time.
IntroductionConfronted with the opioid epidemic, surgeons must play a larger role to reduce risk of opioid abuse while managing acute pain. Having a better understanding of the beliefs and practices of trauma and acute care surgeons regarding discharge pain management may offer potential targets for interventions beyond fixed legal mandates.MethodsAn Institutional Review Board-approved electronic survey was sent to trauma and acute care surgeons who are members of the American Association for the Surgery of Trauma, and trauma and acute care surgeons and nurse practitioners at a Level 1 trauma center in February 2018. The survey included four case-based scenarios and questions about discharge prescription practices and beliefs.ResultsOf 66 respondents, most (88.1%) were at academic institutions. Mean number of opioid tablets prescribed was 20-30 (range 5-90), with the fewest tablets prescribed for elective laparoscopic cholecystectomy and the most for rib fractures. Few prescribed both opioid and non-opioid medications (22.4% to 31.4 %). Most would not change the number/strength of medications (69.2%), dose (53.9%), or number of tablets of opioids (83.1%) prescribed if patients used opioids regularly prior to their operation. The most common factors that made providers more likely to prescribe opioids were high inpatient opioid use (32.4%), history of opioid use/abuse (24.5%), and if the patient lives far from the hospital (12.9%). Most providers in practice >5 years reported a decrease in opioids (71.9%) prescribed at discharge.ConclusionTrauma and acute care surgeons and nurse practitioners reported decreasing the number/amount of opioids prescribed over time. Patients with high opioid use in the hospital, history of opioid use/abuse, or who live far from the provider may be prescribed more opioids at discharge.Level of evidenceLevel IV
Range and Intensity Image-Based Terrain and Vehicle Relative Pose Estimation System
A navigation system includes an image acquisition device for acquiring a range image of a target vehicle, at least one processor, a memory including a target vehicle model and computer readable program code, where the processor and the computer readable program code are configured to cause the navigation system to convert the range image to a point cloud having three dimensions, compute a transform from the target vehicle model to the point cloud, and use the transform to estimate the target vehicle's attitude and position for capturing the target vehicle
Prospective observational study of point-of-care creatinine in trauma.
Background:Patients with trauma are at risk for renal dysfunction from hypovolemia or urological injury. In austere environments, creatinine values are not available to guide resuscitation. A new portable device, the Stat Sensor Point-of-care (POC) Whole Blood Creatinine Analyzer, provides accurate results in <30 s and requires minimal training. This device has not been evaluated in trauma despite the theoretical benefit it provides. The purpose of this study is to determine the clinical impact of the POC device in trauma. Methods:40 patients with trauma were enrolled in a prospective observational study. One drop of blood was used for creatinine determination on the Statsensor POC device. POC creatinine results were compared to the laboratory. Turnaround time (TAT) for POC and laboratory methods was calculated as well as time elapsed to CT scan if applicable. Results:Patients (n=40) were enrolled between December 2014 and March 2015. POC creatinine values were similar to laboratory methods with a mean bias of 0.075±0.27 (p=0.08). Mean analytical TATs for the POC measurements were significantly faster than the laboratory method (11.6±10.0 min vs 78.1±27.9 min, n=40, p<0.0001). Mean elapsed time before arrival at the CT scanner was 52.9±34.2 min. Conclusions:The POC device reported similar creatinine values to the laboratory and provided significantly faster results. POC creatinine testing is a promising development for trauma practice in austere environments and workup of a subset of stable patients with trauma. Further study is warranted to determine clinical impact, both in hospital-based trauma and austere environments
Recommended from our members
Mass casualty events: what to do as the dust settles?
Care during mass casualty events (MCE) has improved during the last 15 years. Military and civilian collaboration has led to partnerships which augment the response to MCE. Much has been written about strategies to deliver care during an MCE, but there is little about how to transition back to normal operations after an event. A panel discussion entitled The Day(s) After: Lessons Learned from Trauma Team Management in the Aftermath of an Unexpected Mass Casualty Event at the 76th Annual American Association for the Surgery of Trauma meeting on September 13, 2017 brought together a cadre of military and civilian surgeons with experience in MCEs. The events described were the First Battle of Mogadishu (1993), the Second Battle of Fallujah (2004), the Bagram Detention Center Rocket Attack (2014), the Boston Marathon Bombing (2013), the Asiana Flight 214 Plane Crash (2013), the Baltimore Riots (2015), and the Orlando Pulse Night Club Shooting (2016). This article focuses on the lessons learned from military and civilian surgeons in the days after MCEs
Pose Measurement Performance of the Argon Relative Navigation Sensor Suite in Simulated Flight Conditions
Argon is a flight-ready sensor suite with two visual cameras, a flash LIDAR, an on- board flight computer, and associated electronics. Argon was designed to provide sensing capabilities for relative navigation during proximity, rendezvous, and docking operations between spacecraft. A rigorous ground test campaign assessed the performance capability of the Argon navigation suite to measure the relative pose of high-fidelity satellite mock-ups during a variety of simulated rendezvous and proximity maneuvers facilitated by robot manipulators in a variety of lighting conditions representative of the orbital environment. A brief description of the Argon suite and test setup are given as well as an analysis of the performance of the system in simulated proximity and rendezvous operations
Systemic anticoagulation in the setting of vascular extremity trauma
Introduction
There is conflicting data regarding if patients with vascular extremity trauma who undergo surgical treatment need to be systematically anticoagulated. We hypothesized that intraoperative systemic anticoagulation (ISA) decreased the risk of repair thrombosis or limb amputation after traumatic vascular injury of the extremities.
Methods
We analyzed a composite risk of repair thrombosis and/or limb amputation (RTLA) between patients who did and did not undergo ISA during arterial injury repair. Patient data was collected in the American Association for the Surgery of Trauma PROspective Vascular Injury Treatment (PROOVIT) registry. This registry contains demographic, diagnostic, treatment, and outcome data.
Results
Between February 2013 and August 2015, 193 patients with upper or lower extremity arterial injuries who underwent open operative repair were entered into the PROOVIT registry. The majority were male (87%) with a mean age of 32.6 years (range 4–91) and 74% injured by penetrating mechanism. 63% of the injuries were described as arterial transection and 37% had concomitant venous injury. 62% of patients underwent ISA. RTLA occurred in 22 patients (11%) overall, with no significant difference in these outcomes between patients who received ISA and those that did not (10% vs. 14%, p = 0.6). There was, however, significantly higher total blood product use noted among patients treated with ISA versus those that did not receive ISA (median 3 units vs. 1 unit, p = 0.002). Patients treated with ISA also stayed longer in the ICU (median 3 days vs. 1 day, p = 0.001) and hospital (median 9.5 days vs. 6 days, p = 0.01).
Discussion
In this multicenter prospective cohort, intraoperative systemic anticoagulation was not associated with a difference in rate of repair thrombosis or limb loss; but was associated with an increase in blood product requirements and prolonged hospital stay. Our data suggest there is no significant difference in outcome to support use of ISA for repair of traumatic arterial injuries
Fast Kalman Filtering for Relative Spacecraft Position and Attitude Estimation for the Raven ISS Hosted Payload
The Raven ISS Hosted Payload will feature several pose measurement sensors on a pan/tilt gimbal which will be used to autonomously track resupply vehicles as they approach and depart the International Space Station. This paper discusses the derivation of a Relative Navigation Filter (RNF) to fuse measurements from the different pose measurement sensors to produce relative position and attitude estimates. The RNF relies on relative translation and orientation kinematics and careful pose sensor modeling to eliminate dependence on orbital position information and associated orbital dynamics models. The filter state is augmented with sensor biases to provide a mechanism for the filter to estimate and mitigate the offset between the measurements from different pose sensor
Adaptation of Brucella melitensis Antimicrobial Susceptibility Testing to the ISO 20776 Standard and Validation of the Method
This article belongs to the Special Issue Emerging Themes in Brucella and Brucellosis.Brucellosis, mainly caused by Brucella (B.) melitensis, is associated with a risk of chronification
and relapses. Antimicrobial susceptibility testing (AST) standards for B. melitensis are not
available, and the agent is not yet listed in the EUCAST breakpoint tables. CLSI recommendations
for B. melitensis exist, but they do not fulfill the requirements of the ISO 20776 standard regarding
the culture medium and the incubation conditions. Under the third EU Health Programme, laboratories
specializing in the diagnostics of highly pathogenic bacteria in their respective countries
formed a working group within a Joint Action aiming to develop a suitable method for the AST of B. melitensis. Under the supervision of EUCAST representatives, this working group adapted the
CLSI M45 document to the ISO 20776 standard after testing and validation. These adaptations included
the comparison of various culture media, culture conditions and AST methods. A Standard
Operation Procedure was derived and an interlaboratory validation was performed in order to evaluate
the method. The results showed pros and cons for both of the two methods but also indicate
that it is not necessary to abandon Mueller–Hinton without additives for the AST of B. melitensis.This research was funded by the EU Health Programme 2014–2020, through the Consumers, Health, Agriculture and Food Executive Agency (CHAFEA, European Commission), the Joint
Action EMERGE (CHAFEA n° 677 066) and the Joint Action SHARP (848096-SHARP JA).info:eu-repo/semantics/publishedVersio
- …