18 research outputs found

    Performance characteristics of the whole-body discovery IQ PET/CT system

    Get PDF
    The aim of this study was to assess the physical performance of a new PET/CT system, the Discovery IQ with 5-ring detector blocks. Methods: Performance was measured using the National Electrical Manufacturers Association NU2-2012 methodology. Image quality was extended by accounting for different acquisition parameters (lesion-to-background ratios [8:1, 4:1, and 2:1] and acquisition times) and reconstruction algorithms (VUE-point HD [VPHD], VPHD with point-spread-function modeling [VPHD-S], and Q.Clear). Tomographic reconstruction was also assessed using a Jaszczak phantom. Additionally, 30 patient lesions were analyzed to account for differences in lesion volume and SUV quantification between reconstruction algorithms. Results: Spatial resolution ranged from 4.2 mm at 1 cm to 8.5 mm at 20 cm. Sensitivity measured at the center and at 10 cm was 22.8 and 20.4 kps/kBq, respectively. The noise-equivalent counting rate peak was 124 kcps at 9.1 kBq/cm3 The scatter fraction was 36.2%. The accuracy of correction for count losses and randoms was 3.9%. In the image quality test, contrast recovery for VPHD, VPHD-S, and Q.Clear ranged from 18%, 18%, and 13%, respectively (hot contrast; 10-mm sphere diameter; ratio, 2:1), to 68%, 67%, and 81%, respectively (cold contrast; 37-mm sphere diameter; ratio, 8:1). Background variability ranged from 3.4%, 3.0%, and 2.1%, respectively (ratio, 2:1), to 5.5%, 4.8%, and 3.7%, respectively (ratio, 8:1). On Q.Clear reconstruction, the decrease in the penalty term (β) increased the contrast recovery coefficients and background variability. With the Jaszczak phantom, image quality increased overall when a reconstruction algorithm modeling the point-spread function was used, and use of Q.Clear increased the signal-to-noise ratio. Lesions analyzed using VPHD-S and Q.Clear had an SUVmean of 6.5 ± 3 and 7 ± 3, respectively (P < 0.01), and an SUVmax of 11 ± 4.8 and 12 ± 4, respectively (P < 0.01). No significant difference in mean lesion volume was found between algorithms. Conclusion: Among the various Discovery bismuth germanium oxide-based PET/CT scanners, the IQ with 5-ring detector blocks has the highest overall performance, with improved sensitivity and counting rate performance. Q.Clear reconstruction improves the PET image quality, with higher recovery coefficients and lower background variability

    Image quality evaluation in a modern PET system: impact of new reconstructions methods and a radiomics approach

    Get PDF
    The present work investigates the influence of different biological and physical parameters on image quality (IQ) perception of the abdominal area in a modern PET scanner, using new reconstruction algorithms and testing the utility of a radiomics approach. Scans of 112 patients were retrospectively included. Images were reconstructed using both OSEM + PSF and BSRM methods, and IQ of the abdominal region was subjectively evaluated. First, 22 IQ related parameters were obtained (including count rate and biological or mixed parameters) and compared to the subjective IQ scores by means of correlations and logistic regression. Second, an additional set of radiomics features was extracted, and a model was constructed by means of an elastic-net regression. For the OSEM + PSF and especially for the BSRM reconstructions, IQ parameters presented only at best moderated correlations with the subjective IQ. None of the studied parameters presented a good predictive power for IQ, while a simple radiomics model increased the performance of the IQ prediction. These results suggest the necessity of changing the standard parameters to evaluate IQ, particularly when a BSRM algorithm is involved. Furthermore, it seems that a simple radiomics model can outperform the use of any single parameter to assess IQ

    Inflammatory processes involved in the alteration of liver function biomarkers in adult hospitalized patients treated with parenteral nutrition

    Get PDF
    IntroductionLiver damage has been associated with the accumulation of phytosterols (PS) in patients treated with parenteral nutrition (PN). We aimed to study the association of inflammatory markers with liver function biomarker (LFB) alterations in patients treated with PN containing PS.Materials and methodsProspective observational study. Simple linear and stepwise multiple linear regression tests and interactions were performed.ResultsNineteen patients were included. In the multivariable model, determinations based on LFBs as dependent and phytosterols (and their fractions) as independent variables showed an association between increases in gamma-glutamyltransferase (GGT) and lanosterol (p &lt; 0.001), stigmasterol (p &lt; 0.001), interleukin-10 (IL-10) × total phytosterols (Phyt) (p &lt; 0.009), tumor necrosis factor-α (TNF-α) × Phyt (p &lt; 0.002), IL-10 × sitosterol (p &lt; 0.002), TNF-α × sitosterol (p &lt; 0.001), IL-10 × campesterol (p &lt; 0.033), IL-10 (p &lt; 0.006 and p &lt; 0.015), TNF-α (p &lt; 0.048 and p &lt; 0.027). Increases in alanine aminotransferase (ALT) were associated with Phyt (p &lt; 0.006), lanosterol (p &lt; 0.016), C-reactive protein (CRP) × campesterol (p &lt; 0.001), interleukin-6 (IL-6) × stigmasterol (p &lt; 0.030), CRP (p &lt; 0.08), and IL-6 (p &lt; 0.042). Alkaline phosphatase (AP) increases were associated with CRP (p &lt; 0.002).DiscussionInflammation in the presence of plasmatic PS seems to have a synergistic effect in impairing liver function, mainly altering GGT but also ALT

    Detection of early seeding of Richter transformation in chronic lymphocytic leukemia

    Get PDF
    Richter transformation (RT) is a paradigmatic evolution of chronic lymphocytic leukemia (CLL) into a very aggressive large B cell lymphoma conferring a dismal prognosis. The mechanisms driving RT remain largely unknown. We characterized the whole genome, epigenome and transcriptome, combined with single-cell DNA/RNA-sequencing analyses and functional experiments, of 19 cases of CLL developing RT. Studying 54 longitudinal samples covering up to 19 years of disease course, we uncovered minute subclones carrying genomic, immunogenetic and transcriptomic features of RT cells already at CLL diagnosis, which were dormant for up to 19 years before transformation. We also identified new driver alterations, discovered a new mutational signature (SBS-RT), recognized an oxidative phosphorylation (OXPHOS)high-B cell receptor (BCR)low-signaling transcriptional axis in RT and showed that OXPHOS inhibition reduces the proliferation of RT cells. These findings demonstrate the early seeding of subclones driving advanced stages of cancer evolution and uncover potential therapeutic targets for RT

    Repensar els estudis catalans des de la teoria queer

    Get PDF
    Catalan Studies are basically focused on national/linguistic identity, but recent debate on Catalan identity triggered by the current pro-independent process in Catalonia, may help reshape this academic field. A more diverse approach to Catalan culture should consider sexuality, which has traditionally been banished from literary analysis as a ‘private’ matter. Here, we discussed how queer theory can reframe Catalan Studies mainly by building a specific LGBT literary tradition, identifying queer episodes and characters in the canon, questioning received meanings, promoting interdisciplinary analysis of Catalan culture and exploring the role of queer subjectivity in history

    Phantom, clinical, and texture indices evaluation and optimization of a penalized-likelihood image reconstruction method (Q.Clear) on a BGO PET/CT scanner

    Get PDF
    INTRODUCTION: The aim of this study was to evaluate the behavior of a penalized-likelihood image reconstruction method (Q.Clear) under different count statistics and lesion-to-background ratios (LBR) on a BGO scanner, in order to obtain an optimum penalization factor (β value) to study and optimize for different acquisition protocols and clinical goals. METHODS: Both phantom and patient images were evaluated. Data from an image quality phantom were acquired using different Lesion-to-Background ratios and acquisition times. Then, each series of the phantom was reconstructed using β values between 50 and 500, at intervals of 50. Hot and cold contrasts were obtained, as well as background variability and contrast-to-noise ratio (CNR). Fifteen 18 F-FDG patients (five brain scans and 10 torso acquisitions) were acquired and reconstructed using the same β values as in the phantom reconstructions. From each lesion in the torso acquisition, noise, contrast, and signal-to-noise ratio (SNR) were computed. Image quality was assessed by two different nuclear medicine physicians. Additionally, the behaviors of 12 different textural indices were studied over 20 different lesions. RESULTS: Q.Clear quantification and optimization in patient studies depends on the activity concentration as well as on the lesion size. In the studied range, an increase on β is translated in a decrease in lesion contrast and noise. The net product is an overall increase in the SNR, presenting a tendency to a steady value similar to the CNR in phantom data. As the activity concentration or the sphere size increase the optimal β increases, similar results are obtained from clinical data. From the subjective quality assessment, the optimal β value for torso scans is in a range between 300 and 400, and from 100 to 200 for brain scans. For the recommended torso β values, texture indices present coefficients of variation below 10%. CONCLUSIONS: Our phantom and patients demonstrate that improvement of CNR and SNR of Q.Clear algorithm which depends on the studied conditions and the penalization factor. Using the Q.Clear reconstruction algorithm in a BGO scanner, a β value of 350 and 200 appears to be the optimal value for 18F-FDG oncology and brain PET/CT, respectively

    Image quality evaluation in a modern PET system: impact of new reconstructions methods and a radiomics approach

    No full text
    The present work investigates the influence of different biological and physical parameters on image quality (IQ) perception of the abdominal area in a modern PET scanner, using new reconstruction algorithms and testing the utility of a radiomics approach. Scans of 112 patients were retrospectively included. Images were reconstructed using both OSEM + PSF and BSRM methods, and IQ of the abdominal region was subjectively evaluated. First, 22 IQ related parameters were obtained (including count rate and biological or mixed parameters) and compared to the subjective IQ scores by means of correlations and logistic regression. Second, an additional set of radiomics features was extracted, and a model was constructed by means of an elastic-net regression. For the OSEM + PSF and especially for the BSRM reconstructions, IQ parameters presented only at best moderated correlations with the subjective IQ. None of the studied parameters presented a good predictive power for IQ, while a simple radiomics model increased the performance of the IQ prediction. These results suggest the necessity of changing the standard parameters to evaluate IQ, particularly when a BSRM algorithm is involved. Furthermore, it seems that a simple radiomics model can outperform the use of any single parameter to assess IQ

    Image quality evaluation in a modern PET system: impact of new reconstructions methods and a radiomics approach

    No full text
    The present work investigates the influence of different biological and physical parameters on image quality (IQ) perception of the abdominal area in a modern PET scanner, using new reconstruction algorithms and testing the utility of a radiomics approach. Scans of 112 patients were retrospectively included. Images were reconstructed using both OSEM + PSF and BSRM methods, and IQ of the abdominal region was subjectively evaluated. First, 22 IQ related parameters were obtained (including count rate and biological or mixed parameters) and compared to the subjective IQ scores by means of correlations and logistic regression. Second, an additional set of radiomics features was extracted, and a model was constructed by means of an elastic-net regression. For the OSEM + PSF and especially for the BSRM reconstructions, IQ parameters presented only at best moderated correlations with the subjective IQ. None of the studied parameters presented a good predictive power for IQ, while a simple radiomics model increased the performance of the IQ prediction. These results suggest the necessity of changing the standard parameters to evaluate IQ, particularly when a BSRM algorithm is involved. Furthermore, it seems that a simple radiomics model can outperform the use of any single parameter to assess IQ