29 research outputs found

    Study of the neutron-rich region in the vicinity of 208Pb via multinucleon transfer reactions

    Get PDF
    The multinucleon transfer reaction mechanism was employed to populate isotopes around the doubly- magic 208 Pb nucleus. We used an unstable 94 Rb beam on 208 Pb targets of different thickness. Transfer channels were studied via the fragment-γ and γ-γ coincidences, by using MINIBALL γ spectrometer coupled to a particle detector. Gamma transitions associated to the different Pb isotopes, populated by the neutron transfers, are discussed in terms of excitation energy and spin. Fragment angular distributions were extracted, andcompared with the reaction model

    Light and heavy fragments mass correlation in the 197Au+130Te transfer reaction

    Get PDF
    We studied multinucleon transfer (MNT) processes in the 197Au+130Te at Elab=1.07 GeV system coupling the PRISMA magnetic spectrometer to NOSE, an ancillary particle detector. We constructed a mass correlation matrix associating to each light fragment identified in PRISMA the corresponding mass distribution of the heavy partner detected in NOSE and, through the comparison with Monte Carlo simulations, we could infer about the role of neutron evaporation in multinucleon transfer reactions for the population of neutron-rich heavy nuclei

    The evolution of diabetic chronic complications after pancreas transplantation

    Get PDF
    Pancreas transplantation is an invasive procedure that can restore and maintain normoglycemic level very successfully and for a prolonged period in DM1 patients. The procedure elevates the morbimortality rates in the first few months following the surgery if compared to kidney transplants with living donors, but it offers a better quality of life to patients

    Microwave sensor system for continuous monitoring of adhesive curing processes

    Full text link
    A microwave sensor system has been developed for monitoring adhesive curing processes. The system provides continuous, real-time information about the curing progress without interfering with the reaction. An open-coaxial resonator is used as the sensor head, and measurements of its resonance frequency and quality factor are performed during cure to follow the reaction progress. Additionally, the system provides other interesting parameters such as reaction rate or cure time. The adhesive dielectric properties can also be computed off-line, which gives additional information about the process. The results given by the system correlate very well with conventional measurement techniques such as differential scanning calorimetry, combining accuracy and rate with simplicity and an affordable cost. © 2012 IOP Publishing Ltd.The authors thank Rut Benavente Martinez for her assistance in the DSC experiments. The contract of BG-B is financed by the Ministry of Science and Innovation of Spain, through the 'Torres Quevedo' Sub-programme, which is also co-financed by the European Social Fund (ESF). This work has been financed by the Ministry of Science and Innovation of Spain through the project MONIDIEL (TEC2008-04109).García Baños, B.; Catalá Civera, JM.; Penaranda-Foix, FL.; Canós Marín, AJ.; Sahuquillo Navarro, O. (2012). Microwave sensor system for continuous monitoring of adhesive curing processes. Measurement Science and Technology. 23(3). https://doi.org/10.1088/0957-0233/23/3/035101S233Jost, M., & Sernek, M. (2008). Shear strength development of the phenol–formaldehyde adhesive bond during cure. Wood Science and Technology, 43(1-2), 153-166. doi:10.1007/s00226-008-0217-2Costa, M. L., Botelho, E. C., Paiva, J. M. F. de, & Rezende, M. C. (2005). Characterization of cure of carbon/epoxy prepreg used in aerospace field. Materials Research, 8(3), 317-322. doi:10.1590/s1516-14392005000300016Chen, J., & Hojjati, M. (2007). Microdielectric analysis and curing kinetics of an epoxy resin system. Polymer Engineering & Science, 47(2), 150-158. doi:10.1002/pen.20687Sernek, M., & Kamke, F. A. (2007). Application of dielectric analysis for monitoring the cure process of phenol formaldehyde adhesive. International Journal of Adhesion and Adhesives, 27(7), 562-567. doi:10.1016/j.ijadhadh.2006.10.004Núñez, L., Gómez-Barreiro, S., Gracia-Fernández, C. A., & Núñez, M. R. (2004). Use of the dielectric analysis to complement previous thermoanalytical studies on the system diglycidyl ether of bisphenol A/1,2 diamine cyclohexane. Polymer, 45(4), 1167-1175. doi:10.1016/j.polymer.2003.12.024Lefebvre, D. R., Han, J., Lipari, J. M., Long, M. A., McSwain, R. L., & Wells, H. C. (2006). Dielectric analysis for in-situ monitoring of gelatin renaturation and crosslinking. Journal of Applied Polymer Science, 101(5), 2765-2775. doi:10.1002/app.21631Cordovez, M., Li, Y., & Karbhari, V. M. (2004). Assessment of Dielectrometry for Characterization of Processing and Moisture Absorption in FRP Composites. Journal of Reinforced Plastics and Composites, 23(4), 445-456. doi:10.1177/0731684404031980Das, N. K., Voda, S. M., & Pozar, D. M. (1987). Two Methods for the Measurement of Substrate Dielectric Constant. IEEE Transactions on Microwave Theory and Techniques, 35(7), 636-642. doi:10.1109/tmtt.1987.1133722Fioretto, D., Livi, A., Rolla, P. A., Socino, G., & Verdini, L. (1994). The dynamics of poly(n-butyl acrylate) above the glass transition. Journal of Physics: Condensed Matter, 6(28), 5295-5302. doi:10.1088/0953-8984/6/28/007Givot, B. L., Krupka, J., & Belete, D. Y. (s. f.). Split post dielectric resonator technique for dielectric cure monitoring of structural adhesives. 13th International Conference on Microwaves, Radar and Wireless Communications. MIKON - 2000. Conference Proceedings (IEEE Cat. No.00EX428). doi:10.1109/mikon.2000.913931Canos, A. J., Catala-Civera, J. M., Penaranda-Foix, F. L., & Reyes-Davo, E. (2006). A novel technique for deembedding the unloaded resonance frequency from measurements of microwave cavities. IEEE Transactions on Microwave Theory and Techniques, 54(8), 3407-3416. doi:10.1109/tmtt.2006.877833Marks, R. B., & Williams, D. F. (1992). A general waveguide circuit theory. Journal of Research of the National Institute of Standards and Technology, 97(5), 533. doi:10.6028/jres.097.024Harrington, R. F. (1967). Matrix methods for field problems. Proceedings of the IEEE, 55(2), 136-149. doi:10.1109/proc.1967.5433Baker-Jarvis, J., Janezic, M. D., Domich, P. D., & Geyer, R. G. (1994). Analysis of an open-ended coaxial probe with lift-off for nondestructive testing. IEEE Transactions on Instrumentation and Measurement, 43(5), 711-718. doi:10.1109/19.328897Taylor, B. N. (1994). Guidelines for evaluating and expressing the uncertainty of NIST measurement results. doi:10.6028/nist.tn.1297Casalini, R., Corezzi, S., Livi, A., Levita, G., & Rolla, P. A. (1997). Dielectric parameters to monitor the crosslink of epoxy resins. Journal of Applied Polymer Science, 65(1), 17-25. doi:10.1002/(sici)1097-4628(19970705)65:13.0.co;2-tPreu, H., & Mengel, M. (2007). Experimental and theoretical study of a fast curing adhesive. International Journal of Adhesion and Adhesives, 27(4), 330-337. doi:10.1016/j.ijadhadh.2006.06.004Harper, D. P., Wolcott, M. P., & Rials, T. G. (2001). Evaluation of the cure kinetics of the wood/pMDI bondline. International Journal of Adhesion and Adhesives, 21(2), 137-144. doi:10.1016/s0143-7496(00)00045-2Garcia-Banos, B., Canos, A. J., Penaranda-Foix, F. L., & Catala-Civera, J. M. (2011). Noninvasive Monitoring of Polymer Curing Reactions by Dielectrometry. IEEE Sensors Journal, 11(1), 62-70. doi:10.1109/jsen.2010.2050475He, Y. (2001). DSC and DEA studies of underfill curing kinetics. Thermochimica Acta, 367-368, 101-106. doi:10.1016/s0040-6031(00)00654-7Núñez-Regueira, L., Gracia-Fernández, C. A., & Gómez-Barreiro, S. (2005). Use of rheology, dielectric analysis and differential scanning calorimetry for gel time determination of a thermoset. Polymer, 46(16), 5979-5985. doi:10.1016/j.polymer.2005.05.06

    Uso do óxido nítrico em pediatria Inhaled nitric oxide in pediatrics

    No full text
    OBJETIVO: Rever a literatura sobre óxido nítrico inalatório e descrever suas principais indicações clínicas em pediatria. FONTES DOS DADOS: Revisão bibliográfica e seleção de publicações mais relevantes sobre óxido nítrico inalatório, utilizando a base de dados Medline (últimos dez anos) e a base de dados Cochrane de revisões sistemáticas. SÍNTESE DOS DADOS: A revisão incluiu os seguintes tópicos: introdução; metabolismo e efeitos biológicos; aplicações clínicas; dose, administração e retirada do gás; precações e efeitos adversos e contra-indicações. Quanto às aplicações clínicas, foram descritos o uso de óxido nítrico em hipertensão pulmonar persistente e insuficiência respiratória de recém-nascidos, síndrome do desconforto respiratório agudo, hipertensão pulmonar primária, cirurgia cardíaca, doença pulmonar obstrutiva crônica, anemia falciforme e broncoespasmo. CONCLUSÕES: O óxido nítrico inalatório é um tratamento com amplas possibilidades de utilização em clínica pediátrica. Seu uso é seguro em ambiente de terapia intensiva sob monitorização rigorosa. Como vasodilatador pulmonar seletivo, o óxido nítrico tem efeitos benéficos sobre as trocas gasosas e ventilação. Estudos controlados que enfoquem a administração precoce do gás são necessários em muitas condições, principalmente na síndrome do desconforto respiratório agudo.<br>OBJECTIVE: To review the literature on inhaled nitric oxide and to describe its main clinical applications in pediatrics. SOURCES OF DATA: A 10 year literature review with selection of the most important publications on inhaled nitric oxide, using the Medline and Cochrane Systematic Review databases. SUMMARY OF THE FINDINGS: This review was organized as follows: introduction; metabolism and biological effects; clinical applications; dosage, gas administration and weaning; precautions and side-effects. Inhaled nitric oxide use was described in persistent pulmonary hypertension and hypoxia of the newborn, acute respiratory distress syndrome, primary pulmonary hypertension, heart surgery, chronic obstructive pulmonary disease, sickle cell anemia, and bronchospastic disease. CONCLUSIONS: Inhaled nitric oxide is a therapeutic approach with wide clinical applications in pediatrics. Its use is safe when administered in pediatric intensive care units under strict monitoring. As a pulmonary vasodilator, nitric oxide has beneficial effects on gas exchange and ventilation. Controlled trials, focusing on early gas administration should be performed under many clinical conditions, especially acute respiratory distress syndrome

    The Times-Journal

    Get PDF
    Daily newspaper from Oklahoma City, Oklahoma Territory that includes local, territorial, and national news along with advertising
    corecore