16 research outputs found

    Morfologia e histoquímica das glândulas de Duvernoy e supralabial de seis espécies de colubrídeos opistoglifodontes (serpentes, Colubridae)

    Get PDF
    Since some colubrids can cause human envenomation, the importance of studies relating biological mechanisms to their venom apparatus is crucial. The present work dealt with morphological and histochemical characteristics of Duvernoy's gland of six opisthoglyphous colubrid species. The Duvernoy's gland of most species presented characteristics of a seromucous gland, except that of Oxyrhopus guibei, which did not show positive reaction to proteins indicating a mucoserous feature. We found variation in the quantity of serous cells among the species. This variation may be related to the presence of substances rich in carbohydrate-protein complex, and consequently to the toxic function of the secretion.Visto que alguns colubrídeos são capazes de causar envenenamento humano, fazem-se necessários estudos capazes de elucidar os mecanismos biológicos relacionados ao aparelho de veneno destes animais. Este estudo abordou características morfológicas e histoquímicas das glândulas de Duvernoy e supralabial de seis espécies de colubrídeos opistoglifodontes. Na maioria das espécies analisadas, a glândula de Duvernoy apresentou características de uma glândula seromucosa, com exceção a de Oxyrhopus guibei que não apresentou positividade à presença de proteínas indicando um caráter mucoseroso. Observou-se ainda, uma variação na quantidade das células serosas dentre as espécies estudadas. Esta variação pode estar relacionada com a presença de substâncias ricas em um complexo carboidrato-proteína e, conseqüentemente, com a função tóxica da secreção

    Influência da temperatura e do fluxo de ar sobre o consumo de ração e ganho de peso em ratos Wistar (Rattus norvegicus) mantidos em sistema microambiental

    Get PDF
    Wistar rats had been kept individually, in metabolic wire cages, without shelter, in microenvironmental system, under direct air flow at 0,6 m/s, under temperatures of 22º, 24º, 26º, 28º and 30º C. The food consumption and the weight gain had been compared in the end of 5 days (ANOVA; Tukey-Kramer). In the total, 7 groups, 10 animals each, had been compared. For the 22ºC temperature, had been used 3 groups, one experimental and two controls. One of them was kept in similar ambient of conventional laboratory animal rooms conditions (general diluitory ventilation, GDV) - C1. The other control group (C2) was kept in the interior of the equipment of microenvironmental ventilation, however, without the direct air flow, simulating the GDV. The gotten results demonstrate clearly that animal kept under direct microenvironmental ventilation at 26º, 28º and 30ºC have the same gain of corporal mass that C1 group. The groups kept at 22º and 24ºC, had less corporal mass gain when compared to C1 (p<0,001 and p<0,01 respectively). The weight gain for all the experimental groups, when compared to C2, presents statistical differences, except 30ºC group, that was equal to C2. The food consumption of all the groups was constant. Only the 30ºC group presented a reduction in the food consumption when compared with the groups C1 and C2 (p<0,05 for the two comparisons).Ratos wistar foram mantidos individualmente, em gaiolas metabólicas de arame, sem abrigo, em sistema microambiental, sob fluxo direto de ar a 0,6 m/s, nas temperaturas de 22º, 24º, 26º, 28º e 30º C. O consumo de ração e o ganho de peso foram comparados do final de 5 dias (ANOVA; Tukey-Kramer). No total, sete grupos de 10 animais cada foram comparados. Para a faixa de 22ºC foram utilizados três grupos, sendo um grupo experimental e dois grupos controles. Um deles foi mantido em condições ambientais semelhantes a biotérios convencionais sob ventilação geral diluidora (VGD) - C1. O outro grupo controle (C2) foi mantido no interior do equipamento de ventilação microambiental, porém, sem o direcionamento de ar, simulando a VGD. Os resultados obtidos demonstram claramente que animais mantidos sob ventilação microambiental direta a 26º, 28º e 30ºC apresentam o mesmo ganho de massa corpórea que animais do grupo C1. Os grupos de animais mantidos a 22º e 24ºC, apresentaram menor ganho de massa corpórea quando comparados a C1 (p<0,001 e p<0,01 respectivamente). O ganho de peso de todos os grupos experimentais, quando comparado ao C2, apresenta diferenças estatísticas, exceto o mantido a 30ºC que apresentou índice de ganho de peso equivalente a C2. O consumo de ração de todos os grupos se manteve constante. Somente o grupo E5 apresentou uma redução no consumo de ração quando comparado aos grupos C1 e C2 (p<0,05 para as duas comparações)

    Reduction of atmospheric ammonia (NH3) and incidence of pulmonary lesions in mice kept in plenum chamber microenvironmental ventilation system

    Get PDF
    In the plenum chamber microenvironmental ventilation system (MEV) for laboratory animal housing, air exchanges are made directly inside animal cages. In this study we measured the daily levels of ammonia (NH3) in cages without beddingchanges and made comparative histopathologieal analyscs of mice born and kept in two different systems. Mice were kept under the MEV (n = 40, in five cages) and general diluting ventilation (GDV) (n= 32, in four cages) systems for nine days. In the MEV system. NH3 was not detected in the first three days, the highest concentration occurred on the seventh day (5.00 +/- 2.90ppm). On the ninth day, a level of 2.50 +/- 1.70 ppm was measured. In GDV. NH3 was detected from the first day, and the highest levels were observed on the third and fifth day (31.20 +/- 12.50 ppm), respectively. Front the fourth to the ninth day, the GDV system presented higher concentrations of NH3 than the MIEV system (p< 0.05). Histopathologieal analyses of lungs of six female mice from each group were performed after keeping mice in the two systems for 56 days. In the score evaluation, the incidence ofehrunie focal pneumonia, catarrhal bronchitis, and interstitial pneumonia was significantly higher (p< 0.05) in the GDV group. Using morphometry, it was observed that animals from the GDV system showed a significant increase (p<005) in the volume fractions of the epithelium, when compared to thc MEV system (2450 +/- 5.60 um3/um2 and 19.70 +/- 4.90 um3/um2, respectively). An estimator of the numerical density of nuclei over 100 um of basement membrane was significantly higher (p<0.05) in animals from the GDV system. when compared to animals from theMEV system (14.60 +/- 3.00 and 10.84 +/- 3.00, respectively). It was shown that animals kept in the MEV system presented better health condition than animals kept in the GDV system

    Use of intracage ventilation systems in animal facilities

    Get PDF
    The breeding and housing of animal species in intensive production systems require a higher control of the environmental variables inside the facilities, on behalf of an atmosphere that maintains a sanitary status and also promotes the well-being of the animals. The husbandry of laboratory animals is one of those productive systems in which the environmental control should be quite rigorous due to the maintenance of defined animals such as specific pathogen-free and gnotobiotics. For a long period, the control of ventilation and environmental factors of conventional animal facilities was achieved by using thermodynamic principles used for human comfort. However, in the last decades, new approaches to solve the environmental problem in animal rooms were studied, and the ventilation systems developed with base in forced convection of the air were the ones that presented the best results until the present time. Thus, this review presents, in an historical perspective, the evolution of alternative devices for caging of laboratory animals and their effects on the animals

    Controle termo-higrométrico microambiental para animais de laboratório por meio de tecnologia termoelétrica: estudo experimental para roedores de laboratório

    Get PDF
    An air conditioner for animal facilities was mounted with thermoelectric modules of Peltier effect. For heat exchange, a water dissipation system was employed.The air temperature difference (Δt) was 21 ºC, the performance was 46.02% and the power consumption was 524 W/h. The mathematical simulation of operation, with mixture of no conditioned air showed that the system can serve approximately 137 standard mouse microisolators, with water dissipation system. The thermoelectric system also showed an accuracy of ± 0.1 ºC at the experimental temperatures, which is impossible in a system of Freon Gas. We tested the following temperatures: 22º, 24º, 26º, 28º and 30 ºC, always getting stability and accuracy at any outside temperature.Um condicionador de ar para biotérios foi montado com módulos termoelétricos de efeito Peltier. Para troca térmica foram empregados dissipadores externos a água, obtendo-se Δt de 21 ºC, rendimento de 46,02%, consumo de 524 W/h. A simulação matemática de operação, com mistura de ar não condicionado, mostrou que o sistema pode servir a aproximadamente 137 microisoladores padrão rato com dissipação externa a água. O sistema termoelétrico mostrou ainda, precisão de ± 0,1 ºC, nas temperaturas experimentais, o que é impossível num sistema de freon. Foram ensaiadas as seguintes temperaturas: 22º, 24º, 26º, 28º e 30 ºC, obtendo sempre estabilidade e precisão, independentemente da temperatura ambiental onde o equipamento estava em operação

    Perfis hematológico e bioquímico de ratos (Rattus norvegicus) mantidos sob sistema de ventilação microambiental

    Get PDF
    Previous studies reported that rats (Rattus norvegicus) kept under microenvironmental ventilation systems (MEV) present better productive and health parameters when compared to animals kept under general diluting ventilation (GDV). The objective of the present research trial was to evaluate hematological and biochemical profiles of rats kept under MVS. In order to achieve this objective, two different trials were designed: Trail 1 (E1), in which it was evaluated the reproductive performance of males and females submitted to two different air speed limits - FV1, from 0.03 to 0.26 m / sec and FV2, from 0.27 to 0.80 m / sec. In Trial 2 (E2) it was evaluated different bed change intervals (3, 5, 7 and 9 days), for males kept under constant air speed (0.5 m / sec). Values for hemogram and biochemical patterns of these animals were compared to those of rats kept under GDV. Results show statistical differences in some of the studied parameters not only for the comparison between GVD and E1 and GVD and E2, but also between both groups submitted to MEV (E1 and E2). However, values found for all studied parameters are inside the normal range reported for this species, what indicates that MEV does not induce important changes in the physiological parameters evaluated.Em estudos anteriores, demonstrou-se que ratos mantidos em sistema de Ventilação Microambiental (VMA) apresentaram parâmetros de produtividade e padrão sanitário melhores do que aqueles mantidos em sistema de Ventilação Geral Diluidora (VGD). Outra etapa dos experimentos foi determinar os parâmetros fisiológicos destes animais. O presente estudo foi realizado para avaliar os perfis hematológico e bioquímico de ratos mantidos sob o sistema de VMA. Para tanto, foram realizados dois experimentos diferentes, com ratos mantidos em VMA, quais sejam: Experimento 1 (E1), no qual foi avaliado o desempenho reprodutivo de machos e fêmeas, sob duas faixas de velocidade de ar (FV1 - de 0,03 a 0,26 m/s, e FV2 - de 0,27 a 0,80 m/s); Experimento 2 (E2), no qual foram avaliados diferentes intervalos de troca de cama (3, 5, 7 e 9 dias), para ratos machos mantidos a uma velocidade de ar constante de 0,5 m/s. Os valores do hemograma e de parâmetros bioquímicos destes animais foram comparados com os valores encontrados em ratos mantidos sob VGD. Os resultados obtidos demonstraram diferenças estatísticas em alguns dos parâmetros observados, tanto entre os sistemas VGD e VMA, como entre os diferentes grupos de VMA. Contudo, os valores encontrados em todos os parâmetros avaliados encontram-se dentro de faixas de variação normal para a espécie estudada, como é descrito na literatura. Isto indica que o emprego do sistema de VMA não induz alterações relevantes nos parâmetros fisiológicos estudados

    Influence of temperature and air flow in the food intake and weigth gain in wistar rats (Rattus norvegicus) kept on microenvironmental system for laboratory animals

    Get PDF
    Ratos wistar foram mantidos individualmente, em gaiolas metabólicas de arame, sem abrigo, em sistema microambiental, sob fluxo direto de ar a 0,6 m/s, nas temperaturas de 22°, 24°, 26°, 28° e 30° C. O consumo de ração e o ganho de peso foram comparados do final de 5 dias (ANOVA; Tukey-Kramer). No total, sete grupos de 10 animais cada foram comparados. Para a faixa de 22°C foram utilizados três grupos, sendo um grupo experimental e dois grupos controles. Um deles foi mantido em condições ambientais semelhantes a biotérios convencionais sob ventilação geral diluidora (VGD) - Cl. O outro grupo controle (C2) foi mantido no interior do equipamento de ventilação microambiental, porém, sem o direcionamento de ar, simulando a VGD. Os resultados obtidos demonstram claramente que animais mantidos sob ventilação microambiental direta a 26°, 28° e 30°C apresentam o mesmo ganho de massa corpórea que animais do grupo C1. Os grupos de animais mantidos a 22° e 24°C, apresentaram menor ganho de massa corpórea quando comparados a Cl (p<0,001 e p<O,Ol respectivamente). O ganho de peso de todos os grupos experimentais, quando comparado ao C2, apresenta diferenças estatísticas, exceto o mantido a 30°C que apresentou índice de ganho de peso equivalente a C2. O consumo de ração de todos os grupos se manteve constante. Somente o grupo ES apresentou uma redução no consumo de ração quando comparado aos grupos Cl e C2 (p<O,OS para as duas comparações)Wistar rats had been kept individually, in metabolic wire cages, without shelter, in microenvironmental system, under direct air flow at 0,6 m/s, under temperatures of22°, 24°, 26°, 28° and 30° C. The food consumption and the weight gain had been compared in the end of 5 days (ANOVA; Tukey-Kramer). In the total, 7 groups, 10 animals each, had been compareci. For the 2TC temperature, had been used 3 groups, one experimental and two controls. One of them was kept in similar ambient of conventional laboratory animal rooms conditions (general diluitory ventilation, GDV) - Cl. The other control group (C2) was kept in the interior cif the equipment of microenvironmental ventilation, however, without the direct air flow, simulating the GDV. The gotten results demonstrate clearly that animalkept under direct microenvirorunental ventilation at 26°, 28° and 30°C have the same gain of corporal mass that Cl group. The groups kept at 22° and 24°C, had less corporal mass gain when compared to Cl (p<O,OOl and p<O,Ol respectively). The weight gain for ali the experimental groups, when compared to C2, presents statistical differences, except 30°C group, that was equal to C2. The food consumption of ali the groups was constant. Only the 30°C group presented a reduction in the food consumption when compared with the groups Cl and C2 (p<O,OS for the two comparisons

    Qualidade do bacalhau salgado seco comercializado em temperatura ambiente e refrigerado

    No full text
    O comércio varejista brasileiro expõe o bacalhau salgado seco, inteiro ou em porções, sem refrigeração. Esta condição, tradicionalmente aceita pelos consumidores, contraria as especificações do fabricante de manter o produto sob refrigeração, o que frequentemente gera conflitos entre as autoridades sanitárias e o comércio. Perante este fato, o presente estudo avaliou parâmetros microbiológicos e físico-químicos de 56 amostras de bacalhau obtidas no município de São Paulo-SP, armazenadas sob refrigeração (0 ° C a 5 ° C) e em temperatura ambiente (20 ° C a 25 ° C), com zero, sete e 14 dias de armazenamento. As amostras foram agrupadas em quatro categorias: (A) amostras refrigeradas não manipuladas e (B), (C) e (D) manipuladas, respectivamente, com zero, sete e 14 dias de armazenamento em temperatura ambiente. A temperatura ambiente variou de 20,5 ° C a 23,5 ° C e a umidade relativa do ar, de 52,5 a 67 %. Foram pesquisados: Staphylococcus coagulase positiva, Clostridium sulfito redutores, coliformes totais e termotolerantes, Salmonella spp., bolores, leveduras e bactérias halofílicas. As análises físico-químicas realizadas foram: umidade, pH, atividade de água (Aa) e resíduo mineral fixo. Não houve diferenças nos resultados microbiológicos obtidos entre as quatro categorias e estes se apresentaram dentro dos limites estabelecidos pela legislação brasileira. Com relação às análises físico-químicas, também não houve diferença estatística entre as quatro categorias. Os valores médios obtidos, por categoria, foram: A: 54,9 % de umidade; Aa = 0,748; pH = 6,0; B: 54,0 % de umidade; Aa = 0,749; pH = 6,0; C: 49,1 % de umidade; Aa = 0,749; pH = 6,0, e para a categoria D: 50,7 % de umidade; Aa = 0,748; pH = 6,0 e 21,6 % de resíduo mineral fixo. Todos os valores de umidade encontrados estavam acima do padrão (35 %); os valores de pH obtidos estavam de acordo com o padrão (6 a 7) e os valores de resíduo mineral fixo atenderam à legislação vigente (mín. 12 %). Com relação à Aa, os valores sugerem que esta é uma importante barreira para o desenvolvimento microbiano e, embora não haja padrão para este parâmetro, julga-se necessário determinar um valor referência como limite máximo. Conclui-se que, nas condições do presente estudo, o comércio do bacalhau salgado seco mantido sob refrigeração ou em temperatura ambiente por 14 dias oferece as mesmas condições de segurança sanitária para o consumidor

    Termohigrometric microenvironmental control for laboratory animals through thermoelectric technology: experimental study for laboratory animals

    Get PDF
    Um condicionador de ar para biotérios foi montado com módulos termoelétricos de efeito Peltier. Para troca térmica foram empregados dissipadores externos a água, obtendo-se Δt de 21 ºC, rendimento de 46,02%, consumo de 524 W/h. A simulação matemática de operação, com mistura de ar não condicionado, mostrou que o sistema pode servir a aproximadamente 137 microisoladores padrão rato com dissipação externa a água. O sistema termoelétrico mostrou ainda, precisão de ± 0,1 ºC, nas temperaturas experimentais, o que é impossível num sistema de freon. Foram ensaiadas as seguintes temperaturas: 22º, 24º, 26º, 28º e 30 ºC, obtendo sempre estabilidade e precisão, independentemente da temperatura ambiental onde o equipamento estava em operaçãoAn air conditioner for animal facilities was mounted with thermoelectric modules of Peltier effect. For heat exchange, a water dissipation system was employed.The air temperature difference (Δt) was 21 ºC, the performance was 46.02% and the power consumption was 524 W/h. The mathematical simulation of operation, with mixture of no conditioned air showed that the system can serve approximately 137 standard mouse microisolators, with water dissipation system. The thermoelectric system also showed an accuracy of ± 0.1 ºC at the experimental temperatures, which is impossible in a system of Freon Gas. We tested the following temperatures: 22º, 24º, 26º, 28º and 30 ºC, always getting stability and accuracy at any outside temperatureFAPESP 02/09908-
    corecore