4,388 research outputs found

    Finite-Difference Time-Domain Simulation for Three-dimensional Polarized Light Imaging

    Full text link
    Three-dimensional Polarized Light Imaging (3D-PLI) is a promising technique to reconstruct the nerve fiber architecture of human post-mortem brains from birefringence measurements of histological brain sections with micrometer resolution. To better understand how the reconstructed fiber orientations are related to the underlying fiber structure, numerical simulations are employed. Here, we present two complementary simulation approaches that reproduce the entire 3D-PLI analysis: First, we give a short review on a simulation approach that uses the Jones matrix calculus to model the birefringent myelin sheaths. Afterwards, we introduce a more sophisticated simulation tool: a 3D Maxwell solver based on a Finite-Difference Time-Domain algorithm that simulates the propagation of the electromagnetic light wave through the brain tissue. We demonstrate that the Maxwell solver is a valuable tool to better understand the interaction of polarized light with brain tissue and to enhance the accuracy of the fiber orientations extracted by 3D-PLI.Comment: 13 pages, 5 figure

    An integrated and multi-purpose microscope for the characterization of atomically thin optoelectronic devices

    Get PDF
    This is the author accepted manuscript. The final version is available from AIP Publishing via the DOI in this record.Optoelectronic devices based on graphene and other two-dimensional (2D) materials, such as transition metal dichalcogenides (TMDs) are the focus of wide research interest. They can be the key to improving bandwidths in telecommunications, capacity in data storage, new features in consumer electronics, safety devices and medical equipment. The characterization these emerging atomically thin materials and devices strongly relies on a set of measurements involving both optical and electronic instrumentation ranging from scanning photocurrent mapping to Raman and photoluminescence (PL) spectroscopy. Current state-of-the-art commercial instruments offer the ability to characterize individual properties of these materials with no option for the in situ characterization of a wide enough range of complementary optical and electrical properties. Presently, the requirement to switch atomically-thin materials from one system to another often radically affects the properties of these uniquely sensitive materials through atmospheric contamination. Here, we present an integrated, multi-purpose instrument dedicated to the optical and electrical characterization of devices based on 2D materials which is able to perform low frequency electrical measurements, scanning photocurrent mapping, Raman, absorption and PL spectroscopy in one single set-up with full control over the polarization and wavelength of light. We characterize this apparatus by performing multiple measurements on graphene, transition metal dichalcogenides (TMDs) and Si. The performance and resolution is equivalent to commercially available instruments with the significant added value of being a compact, multi-purpose unit. Our design offers a versatile solution to face the challenges imposed by the advent of atomically-thin materials in optoelectronic devices

    Homogeneously Bright, Flexible, and Foldable Lighting Devices with Functionalized Graphene Electrodes.

    Get PDF
    Alternating current electroluminescent technology allows the fabrication of large area, flat and flexible lights. Presently the maximum size of a continuous panel is limited by the high resistivity of available transparent electrode materials causing a visible gradient of brightness. Here, we demonstrate that the use of the best known transparent conductor FeCl3-intercalated few-layer graphene boosts the brightness of electroluminescent devices by 49% compared to pristine graphene. Intensity gradients observed for high aspect ratio devices are undetectable when using these highly conductive electrodes. Flat lights on polymer substrates are found to be resilient to repeated and flexural strains.S. Russo and M.F. Craciun acknoweldge financial support from EPSRC (Grant no. EP/J000396/1, EP/K017160/1, EP/K010050/1, EPG036101/1, EP/M001024/1, EPM002438/1) and from the Leverhulme Trust (Research grant title Quantum Drums)

    Extraordinary linear dynamic range in laser-defined functionalized graphene photodetectors

    Get PDF
    This is the author accepted manuscript. The final version is available from AAAS via the DOI in this record.Graphene-based photodetectors have demonstrated mechanical flexibility, large operating bandwidth, and broadband spectral response. However, their linear dynamic range (LDR) is limited by graphene’s intrinsic hot-carrier dynamics, which causes deviation from a linear photoresponse at low incident powers. At the same time, multiplication of hot carriers causes the photoactive region to be smeared over distances of a few micrometers, limiting the use of graphene in high-resolution applications. We present a novel method for engineering photoactive junctions in FeCl3-intercalated graphene using laser irradiation. Photocurrent measured at these planar junctions shows an extraordinary linear response with an LDR value at least 4500 times larger than that of other graphene devices (44 dB) while maintaining high stability against environmental contamination without the need for encapsulation. The observed photoresponse is purely photovoltaic, demonstrating complete quenching of hot-carrier effects. These results pave the way toward the design of ultrathin photodetectors with unprecedented LDR for high-definition imaging and sensing.S.R. and M.F.C. acknowledge financial support from the Engineering and Physical Sciences Research Council (grant nos. EP/J000396/1, EP/K017160/1, EP/K010050/1, EP/G036101/1, EP/M001024/1, and EP/M002438/1), from the Royal Society’s International Exchanges Scheme 2012/R3 and 2013/R2, and from the European Commission (FP7-ICT-2013-613024-GRASP)

    High Efficiency CVD Graphene-lead (Pb) Cooper Pair Splitter

    Get PDF
    This is the final version of the article. Available from the publisher via the DOI in this record.We demonstrate high efficiency Cooper pair splitting in a graphene-based device. We utilize a true Y-shape design effectively placing the splitting channels closer together: graphene is used as the central superconducting electrode as well as QD output channels, unlike previous designs where a conventional superconductor was used with tunnel barriers to the quantum dots (QD) of a different material. Superconductivity in graphene is induced via the proximity effect, thus resulting in both a large measured superconducting gap Δ=0.5\Delta=0.5meV, and a long coherence length ξ=200\xi=200nm. The graphene-graphene, flat, two dimensional, superconductor-QD interface lowers the capacitance of the quantum dots, thus increasing the charging energy ECE_C (in contrast to previous devices). As a result we measure a visibility of up to 96% and a splitting efficiency of up to 62%. Finally, the devices utilize graphene grown by chemical vapor deposition allowing for a standardized device design with potential for increased complexity.I. V. B. acknowledges the JSPS International Research Fellowship. M. Y. and S. T. acknowledge financial support by Grant-in-Aid for Scientific Research S (No. 26220710) and Grant-in-Aid for Scientific Research A (No. 26247050). M. Y. acknowledges financial support by Grant-in-Aid for Scientific Research on Innovative Areas ”Science of Atomic Layers” and Canon foundation. S. T. acknowledges financial support by MEXT project for Developing Innovation Systems and JST Strategic International Cooperative Program. S. R. and M. F. C. acknowledge financial support from EPSRC (Grant EP/J000396/1, EP/K017160, EP/K010050/1, EP/G036101/1, EP/M002438/1, EP/M001024/1), from the Royal Society Travel Exchange Grants 2012 and 2013 and from the Leverhulme Trust

    Large-area functionalized CVD graphene for work function matched transparent electrodes

    Get PDF
    PublishedArticleThe efficiency of flexible photovoltaic and organic light emitting devices is heavily dependent on the availability of flexible and transparent conductors with at least a similar workfunction to that of Indium Tin Oxide. Here we present the first study of the work function of large area (up to 9 cm2) FeCl3 intercalated graphene grown by chemical vapour deposition on Nickel, and demonstrate values as large as 5.1 eV. Upon intercalation, a charge density per graphene layer of 5 ⋅ 1013 ± 5 ⋅ 1012 cm−2 is attained, making this material an attractive platform for the study of plasmonic excitations in the infrared wavelength spectrum of interest to the telecommunication industry. Finally, we demonstrate the potential of this material for flexible electronics in a transparent circuit on a polyethylene naphthalate substrate.EPSRCRoyal Society international Exchanges Schem

    Fast and Highly Sensitive Ionic-Polymer-Gated WS2 -Graphene Photodetectors

    Get PDF
    This is the final version of the article. Available from Wiley via the DOI in this record.The combination of graphene with semiconductor materials in heterostructure photodetectors enables amplified detection of femtowatt light signals using micrometer-scale electronic devices. Presently, long-lived charge traps limit the speed of such detectors, and impractical strategies, e.g., the use of large gate-voltage pulses, have been employed to achieve bandwidths suitable for applications such as video-frame-rate imaging. Here, atomically thin graphene-WS2 heterostructure photodetectors encapsulated in an ionic polymer are reported, which are uniquely able to operate at bandwidths up to 1.5 kHz whilst maintaining internal gain as large as 10(6) . Highly mobile ions and the nanometer-scale Debye length of the ionic polymer are used to screen charge traps and tune the Fermi level of the graphene over an unprecedented range at the interface with WS2 . Responsivity R = 10(6) A W(-1) and detectivity D* = 3.8 × 10(11) Jones are observed, approaching that of single-photon counters. The combination of both high responsivity and fast response times makes these photodetectors suitable for video-frame-rate imaging applications.J.D.M. acknowledges financial support from the Engineering and Physical Sciences Research Council (EPSRC) of the United Kingdom, via the EPSRC Centre for Doctoral Training in Metamaterials (Grant No. EP/L015331/1 ). S.F.R acknowledges financial support from the Higher Committee for Education Development in Iraq (HCED). S.R. and M.F.C. acknowledge financial support from EPSRC (Grant No. EP/J000396/1, EP/K017160/1, EP/K010050/1, EP/G036101/1, EP/M001024/1, and EP/M002438/1) and from Royal Society International Exchanges Scheme 2016/R1

    Target product profiles for protecting against outdoor malaria transmission.

    Get PDF
    BACKGROUND\ud \ud Long-lasting insecticidal nets (LLINs) and indoor residual sprays (IRS) have decimated malaria transmission by killing indoor-feeding mosquitoes. However, complete elimination of malaria transmission with these proven methods is confounded by vectors that evade pesticide contact by feeding outdoors.\ud \ud METHODS\ud \ud For any assumed level of indoor coverage and personal protective efficacy with insecticidal products, process-explicit malaria transmission models suggest that insecticides that repel mosquitoes will achieve less impact upon transmission than those that kill them outright. Here such models are extended to explore how outdoor use of products containing either contact toxins or spatial repellents might augment or attenuate impact of high indoor coverage of LLINs relying primarily upon contact toxicity.\ud \ud RESULTS\ud \ud LLIN impact could be dramatically enhanced by high coverage with spatial repellents conferring near-complete personal protection, but only if combined indoor use of both measures can be avoided where vectors persist that prefer feeding indoors upon humans. While very high levels of coverage and efficacy will be required for spatial repellents to substantially augment the impact of LLINs or IRS, these ambitious targets may well be at least as practically achievable as the lower requirements for equivalent impact using contact insecticides.\ud \ud CONCLUSIONS\ud \ud Vapour-phase repellents may be more acceptable, practical and effective than contact insecticides for preventing outdoor malaria transmission because they need not be applied to skin or clothing and may protect multiple occupants of spaces outside of treatable structures such as nets or houses

    Does undertaking an intercalated BSc influence first clinical year exam results at a London medical school?

    Get PDF
    Background: Intercalated BScs (iBScs) are an optional part of the medical school curriculum in many Universities. Does undertaking an iBSc influence subsequent student performance? Previous studies addressing this question have been flawed by iBSc students being highly selected. This study looks at data from medical students where there is a compulsory iBSc for non-graduates. Our aim was to see whether there was any difference in performance between students who took an iBSc before or after their third year (first clinical year) exams.Methods: A multivariable analysis was performed to compare the third year results of students at one London medical school who had or had not completed their iBSc by the start of this year (n = 276). A general linear model was applied to adjust for differences between the two groups in terms of potential confounders (age, sex, nationality and baseline performance).Results: The results of third year summative exams for 276 students were analysed (184 students with an iBSc and 92 without). Unadjusted analysis showed students who took an iBSc before their third year achieved significantly higher end of year marks than those who did not with a mean score difference of 4.4 (0.9 to 7.9 95% CI, p = 0.01). (overall mean score 238.4 "completed iBSc" students versus 234.0 "not completed", range 145.2 - 272.3 out of 300). There was however a significant difference between the two groups in their prior second year exam marks with those choosing to intercalate before their third year having higher marks. Adjusting for this, the difference in overall exam scores was no longer significant with a mean score difference of 1.4 (-4.9 to +7.7 95% CI, p = 0.66). (overall mean score 238.0 "completed iBSc" students versus 236.5 "not completed").Conclusions: Once possible confounders are controlled for (age, sex, previous academic performance) undertaking an iBSc does not influence third year exam results. One explanation for this confounding in unadjusted results is that students who do better in their second year exams are more likely to take an iBSc before their third year

    Discovery Potential for Low-Scale Gauge Mediation at Early LHC

    Full text link
    Low-scale gauge-mediated supersymmetry(SUSY)-breaking (GMSB) models with gravitino mass m_{3/2}<16 eV are attractive, since there are no flavor and cosmological problems. In this paper, we thoroughly study the collider signal in the case that the next-to-lightest SUSY particle is the bino or slepton and investigate the discovery potential of the LHC. Our result is applicable to a wider class of GMSB models other than the minimal GMSB models and we pay particular attention to realistic experimental setups. We also apply our analysis to the minimal GMSB models with a metastable SUSY-breaking vacuum and we show, by requiring sufficient stability of the SUSY-breaking vacuum, these models can be tested at an early stage of the LHC.Comment: 21 pages, 7 figures.Texts in section 3.2.2 and 3.2.4 are revised. Captions change
    corecore