2,580 research outputs found

    Joinder of the Liability Insurer as a Party Defendant

    Get PDF

    Civil Procedure

    Get PDF

    The interaction of class and gender in illness narratives

    Get PDF
    This is the author's accepted manuscript. The final published article is available from the link below. Copyright @ 2008 BSA Publications Ltd.Perspectives on gender and identity that emphasize variability of performance, local context and individual agency have displaced earlier paradigms.These are now perceived to have supported gender stereotypes and language ideologies by emphasizing gender difference and homogeneity within genders. In a secondary analysis of health and illness narratives we explore the interaction of class and gender in individuals' constructions of gendered identity. High social class men perform gender in particularly varied ways and we speculate that this variable repertoire, including the use of what was once termed `women's language', is linked to a capacity to maintain social distinction and authority. Men's performance of conventional masculinity is often threatened by both the experience of illness and being interviewed about personal experience. Lower social class women in particular demonstrate an intensification of a pre-existing informal family and support group culture, marking successful members by awarding them the accolade of being `lovely'.ESR

    Passive Avoidance Training and Recall are Associated With Increased Glutamate Levels in the Intermediate Medial Hyperstriatum Ventrale of the Day-Old Chick

    Get PDF
    In the young chick, the intermediate medial hyperstriatum ventrale is involved in learning paradigms, including imprinting and passive avoidance learning. Biochemical changes in the intermediate medial hyperstriatum ventrale following learning include an up-regulation of amino-acid transmitter levels and receptor activity. To follow the changes of extracellular amino acid levels during passive avoidance training, we used an in vivo microdialysis technique. Probes were implanted in chicks before training the animals, either on a methyl- anthranylate-or water-coated bead. One hour later, recall was tested in both groups by presenting a similar bead. An increase of extra-cellular glutamate levels accompanied training and testing in both groups; during training, glutamate release was higher in methylanthranylate- trained than in water-trained chicks. When compared with the methylanthranylate-trained chicks during testing, the water-trained chicks showed enhanced extra-cellular glutamate levels. No other amino acid examined showed significant changes. After testing, the chicks were anesthetized and release- stimulated with an infusion of 50 mM potassium. Extra-cellular glutamate and taurine levels were significantly increased in both methylanthranylate-and water-trained chicks. The presentation of methylanthranylate as an. olfactory stimulus significantly enhanced glutamate levels, especially in methylanthranylate-trained chicks. The results suggest that such changes in extra-cellular glutamate levels in the intermediate medial hyperstriatum ventrale accompany pecking at either the water- or the methylanthranylate-bead. The taste of the aversant may be responsible for the greater increases found in methylanthranylate-trained birds

    Comparison of the Sentinel-3A and B SLSTR Tandem Phase Data using metrological principles

    Get PDF
    The Sentinel 3 mission is part of the Copernicus programme space segment and has the objective of making global operational observations of ocean and land parameters with its four onboard sensors. Two Sentinel 3 satellites are currently on orbit, providing near-daily global coverage. Sentinel 3A was launched on 16 February 2016 and Sentinel 3B on 25 April 2018. For the early part of its operation, Sentinel 3B flew in tandem with Sentinel 3A, flying 30 seconds ahead of its twin mission. This provided a unique opportunity to compare the instruments on the two satellites, and to test the per pixel uncertainty values in a metrologically-robust manner. In this work we consider the tandem-phase data from the infrared channels of one of the onboard instruments: the Sea and Land Surface Temperature Radiometer, SLSTR. A direct comparison was made of both the Level 1 radiance values and the Level 2 sea surface temperature values derived from those radiances. At Level 1 the distribution of differences between the sensor values were compared to the declared uncertainties for data gridded on to a regular latitude-longitude grid with propagated pixel uncertainties. The results showed good overall radiometric agreement between the two sensors, with mean differences of ∼0.06 K, although there was a scene-temperature dependent difference for the oblique view that was consistent with what was expected from a stray light effect observed pre-flight. We propose a means to correct for this effect based on the tandem data. Level 1 uncertainties were found to be representative of the variance of the data, expect in those channels affected by the stray light effect. The sea surface temperature results show a very small difference between the sensors that could be in part due to the fact that the Sentinel-3A retrieval coefficients were also applied to the Sentinel-3B retrieval because the Sentinel-3B coefficients are not currently available. This will lead to small errors between the S3A and S3B retrievals. The comparison also suggests that the retrieval uncertainties may need updating for two of the retrieval processes, that there are extra components of uncertainty related the quality level and the probability of cloud that should be included. Finally, a study of the quality flags assigned to sea surface temperature pixel values provided valuable insight into the origin of those quality levels and highlighted possible uncertainties in the defined quality level

    Induction of heme-oxygenase-1 (HO-1) does not enhance adiponectin production in human adipocytes: evidence against a direct HO-1 - Adiponectin axis

    Get PDF
    Adiponectin is a salutary adipokine and hypoadiponectinemia is implicated in the aetiology of obesity-related inflammation and cardiometabolic disease making therapeutic strategies to increase adiponectin attractive. Emerging evidence, predominantly from preclinical studies, suggests induction of heme-oxygenase-1 (HO-1) increases adiponectin production and reduces inflammatory tone. Here, we aimed to test whether induction of HO-1 enhanced adiponectin production from mature adipocytes. Treatment of human adipocytes with cobalt protoporphyrin (CoPP) or hemin for 24-48 h increased HO-1 expression and activity without affecting adiponectin expression and secretion. Treatment of adipocytes with TNFα reduced adiponectin secretion and increased expression and secretion of additional pro-inflammatory cytokines, IL-6 and MCP-1, as well as expression of sXBP-1, a marker of ER stress. HO-1 induction failed to reverse these effects. These results demonstrate that induction of HO-1 does not directly enhance adiponectin production or ameliorate the pro-inflammatory effects of TNFα and argue against a direct HO-1 - adiponectin axis. © 2015 Elsevier Ireland Ltd

    Integrated Refrigeration and Storage of LNG for Compositional Stability

    Get PDF
    Growing interest in liquefied natural gas (LNG) as a rocket fuel necessitates a greater technical understanding of the compositional changes due to preferential boil-off (or weathering) that occurs during long duration storage. The purity of methane in LNG can range from 90 to 98%, and is subject to preferential boil-off due to its low boiling point compared to other constituents despite the use of high-performance thermal insulation systems. Active heat extraction (i.e. refrigeration) is required to completely eliminate weathering. For future operational safety and reliability, and to better understand the quality and efficiency of the LNG as a cryofuel, a 400-liter Cryostat vessel was designed and constructed to measure the composition and temperatures of the LNG at a number of different liquid levels over long durations. The vessel is the centerpiece of a custom-designed lab-scale integrated refrigeration and storage (IRaS) system employing a pulse tube cryocooler capable of roughly 50 W of lift at 100 K. Instrumentation includes ten temperature sensors mounted on a vertical rake and five liquid sample tubes corresponding to five liquid levels. Two modes of operation are studied. The first is without refrigeration in order to determine a baseline in the change in composition, and to study stratification of the LNG. The second is performed with the cryocooler active to determine the operational parameters of the IRaS system for eliminating the weathering as well as stratification effects in the bulk liquid. The apparatus design and test method, as well as preliminary test results are presented in this paper. As a bonus in cost-saving and operational efficiency, the capability of the IRaS system to provide zero-loss capabilities such as zero boil-off (ZBO) keeping of the LNG and zero-loss filling/transfer operations are also discussed

    Disc degeneration and cervical spine intervertebral motion: A Cross-sectional study in patients with neck pain and matched healthy controls

    Get PDF
    While neck pain can be defined in clinical terms, in most cases the underlying pathophysiology is largely unknown. Regional cervical spine range of motion is often found to be reduced in patients with neck pain compared to persons without pain although it is not clear if the decreased range is cause or effect. Less is known about the role of intervertebral kinematics and how that might be related to the presence of disc degeneration. In this study, the prevalence of intervertebral disc degeneration and continuous cervical intervertebral motion were both measured utilizing quantitative fluoroscopy (QF) in patients with subacute or chronic neck pain (n = 29) and gender-matched healthy controls (n = 30). A composite disc degeneration (CDD) score was calculated for each participant from the first, neutral, lateral fluoroscopic image. Intervertebral motion sharing parameters of motionsharing inequality (MSI) and motion-sharing variability (MSV) were derived from the active cervical motion sequences obtained while patients were seated. The objective was to determine if average age, CDD, MSI, and MSV values were correlated and if there were differences in these variables between the neck pain group and the healthy control group. Correlation analysis was conducted for age, CDD, MSI, and MSV in each group. Age was moderately correlated with MSV in cervical spine extension in patients only (r = 0.63, p < 0.001). There were no significant differences in the prevalence of disc degeneration (CDD) between patients, who had on average mild pain and related disability, and healthy controls (median CDD 2 both groups, p = 0.94). There were also no significant differences in either flexion or extension intervertebral motion-sharing inequality or variability (MSI or MSV) between groups as measured during active cervical motion
    • …
    corecore