498 research outputs found

    Experimental verification of position-dependent angular-momentum selection rules for absorption of twisted light by a bound electron

    Get PDF
    We analyze the multipole excitation of atoms with twisted light, i.e, by a vortex light field that carries orbital angular momentum. A single trapped 40Ca+ ion serves as a localized and positioned probe of the exciting field. We drive the transition and observe the relative strengths of different transitions, depending on the ion's transversal position with respect to the center of the vortex light field. On the other hand, transition amplitudes are calculated for a twisted light field in form of a Bessel beam, a Bessel-Gauss and a Laguerre-Gauss mode. Analyzing experimental obtained transition amplitudes we find agreement with the theoretical predictions at a level of better than 3%. Finally, we propose measurement schemes with two-ion crystals to enhance the sensing accuracy of vortex modes in future experiments.Fil: Afanasev, Andrei. The George Washington University; Estados UnidosFil: Carlson, Carl E.. College of William and Mary; Estados UnidosFil: Schmiegelow, Christian Tomás. Johannes Gutenberg University Mainz. Institute of Physics; Alemania. Consejo Nacional de Investigaciones Científicas y Técnicas. Oficina de Coordinación Administrativa Ciudad Universitaria. Instituto de Física de Buenos Aires. Universidad de Buenos Aires. Facultad de Ciencias Exactas y Naturales. Instituto de Física de Buenos Aires; ArgentinaFil: Schulz, Jonas. Johannes Gutenberg University Mainz. Institute of Physics; AlemaniaFil: Schmidt-kaler, Ferdinand. Johannes Gutenberg University Mainz. Institute of Physics; AlemaniaFil: Solyanik, Maria. The George Washington University; Estados Unido

    Quantum phase transitions in disordered dimerized quantum spin models and the Harris criterion

    Get PDF
    We use quantum Monte Carlo simulations to study effects of disorder on the quantum phase transition occurring versus the ratio g=J/J' in square-lattice dimerized S=1/2 Heisenberg antiferromagnets with intra- and inter-dimer couplings J and J'. The dimers are either randomly distributed (as in the classical dimer model), or come in parallel pairs with horizontal or vertical orientation. In both cases the transition violates the Harris criterion, according to which the correlation-length exponent should satisfy nu >= 1. We do not detect any deviations from the three-dimensional O(3) universality class obtaining in the absence of disorder (where nu = 0.71). We discuss special circumstances which allow nu<1 for the type of disorder considered here.Comment: 4+ pages, 3 figure

    Predictors of Ventricular Fibrillation at Reperfusion in Patients With Acute ST-Elevation Myocardial Infarction Treated by Primary Percutaneous Coronary Intervention.

    Get PDF
    Ventricular fibrillation (VF) during reperfusion (rVF) in ST-segment elevation myocardial infarction (STEMI) is an infrequent but serious event that complicates coronary interventions. The aim of this study was to analyze clinical predictors of rVF in an unselected population of patients with STEMI treated with percutaneous coronary intervention (PCI). Consecutive patients with STEMI admitted to a tertiary care hospital for primary PCI from 2007 to 2012 were retrospectively assessed for the presence of rVF. Admission electrocardiograms, stored in a digital format, were analyzed for a maximal ST-segment elevation in a single lead and the sum of ST-segment deviations in all leads. Clinical, electrocardiographic, and angiographic characteristics were tested for associations with rVF using logistic regression analysis. Among 3,724 patients with STEMI admitted from 2007 to 2012, 71 (1.9%) had rVF. In univariate analysis, history of myocardial infarction, aspirin and β-blocker use, VF before PCI, left main coronary artery disease, inferior myocardial infarction localization, symptom-to-balloon time 300 μV, and sum of ST-segment deviations in all leads >1,500 μV were associated with increased risk for rVF. In a multivariate analysis, sum of ST-segment deviations in all leads >1500 μV (odds ratio 3.7, 95% confidence interval 1.45 to 9.41, p = 0.006) before PCI remained an independent predictor of rVF. In-hospital mortality was 18.3% in the rVF group and 3.3% in the group without VF (p <0.001), but rVF was not an independent predictor of in-hospital death. In conclusion, the magnitude of ST-segment elevation before PCI for STEMI independently predicts rVF and should be considered in periprocedural arrhythmic risk assessment. Despite higher in-hospital mortality in patients with rVF, rVF itself has no independent prognostic value for prognosis

    Optimal Robot Placement for Tasks Execution

    Get PDF
    AbstractAutomotive assembly cells are cluttered environments, including robots, workpieces, and fixtures. Due to high volumes and several product variants assembled in the same cell, robot placement is crucial to increase flexibility and throughput. In this paper, we propose a novel method to optimize the base position of an industrial robot with the objective to reach all predefined tasks and minimize cycle time: robot inverse kinematics and collision avoidance are integrated together with a derivative-free optimization algorithm. This approach is successfully used to find feasible solutions on industrial test cases, showing up to 20% cycle time improvement

    Trends in one-year outcomes of dialysis-requiring acute kidney injury in Denmark 2005-2012:a population-based nationwide study

    Get PDF
    Dialysis-requiring acute kidney injury (AKI) is associated with substantial mortality and risk of end-stage renal disease (ESRD). Despite considerable growth in incidence of severe AKI, information pertaining to trends in outcomes remains limited. We evaluated time trends in one year risks of ESRD and death in patients with dialysis-requiring AKI over an eight year period in Denmark.In a retrospective nationwide study based on national registers, all adults requiring acute renal replacement therapy between 2005 and 2012 were identified. Patients with preceding ESRD were excluded. Through individual-level cross-referencing of administrative registries, information pertaining to comorbidity, preceding surgical interventions, and concurrent other organ failure and sepsis was ascertained. Comparisons of period-specific one year odds ratios for ESRD and death were calculated in a multiple logistic regression model.A total of 13,819 patients with dialysis-requiring AKI were included in the study. Within one year, 1,017 (7.4%) patients were registered with ESRD, and 7,908 (57.2%) patients died. The one-year rate of ESRD decreased from 9.0% between 2005 and 2006 to 6.1% between 2011 and 2012. Simultaneously, the one-year mortality rate decreased from 58.2% between 2005 and 2006 to 57.5% between 2011 and 2012. Consequently, the adjusted odds ratios for the period 2011-2012 (with the period 2005-2006 as reference) were 0.75 (0.60-0.95, p = 0.015) and 0.87 (95% CI 0.78-0.97, p = 0.010) for ESRD and death, respectively.In a nationwide retrospective study on time trends in one year outcomes following dialysis-requiring AKI, risk of all-cause mortality and ESRD decreased over a period of 8 years

    Risk of incident atrial fibrillation in patients presenting with retinal artery or vein occlusion:a nationwide cohort study

    Get PDF
    Abstract Background The inter-relationships of atrial fibrillation (AF) to retinal vascular occlusions (whether retinal artery occlusion (RAO) or retinal venous occlusion (RVO)) remain unclear. It is unknown if a presentation of retinal artery or venous occlusions may indicate a new onset cardiac arrhythmia. To shed light on this association, we investigated the risk of new onset AF in patients with known RAO and RVO. Methods Patients with retinal occlusions from 1997 to 2011 were identified through Danish nationwide registries and matched 1:5 according to sex and age. Cumulative incidence and unadjusted rates of AF according to retinal vascular occlusions (i.e. RAO or RVO) were determined. Hazard ratios (HR) of AF according to retinal vascular occlusion were adjusted for hypertension, diabetes, vascular disease and prior stroke/systemic thromboembolism/transient ischemic attack. Results One thousand three hundred sixty-eight cases with retinal vascular occlusions were identified (median age 71.4 (inter quartile range (IQR); 61.2–79.8), 47.3% male). RAO constituted 706 cases (51.6%) and RVO 529 (38.7%). The rate of incident AF amongst all cases with retinal vascular occlusion was 1.74 per 100 person-years (95% confidence interval (CI), 1.47–2.06) compared to 1.22 (95% CI, 1.12–1.33) in the matched control group. The rate of AF in RAO was 2.01 (95% CI, 1.6–2.52) and 1.52 (1.15–2.01) in RVO. HRs of incident AF adjusted for cardiovascular comorbidities were 1.26 (95% CI; 1.04–1.53, p = 0.019) for any retinal vascular occlusion, 1.45 (95% CI; 1.10–1.89, p = 0.015) for RAO, and 1.02 (95% CI; 0.74–1.39, p = 0.920) for RVO. Conclusions A new diagnosis of retinal vascular occlusion in patients without prior AF was associated with increased risk of incident AF, particularly amongst patients with RAO. Awareness of AF in patients with retinal vascular occlusions is advised

    Characterization and Purification of Polydisperse Reconstituted Lipoproteins and Nanolipoprotein Particles

    Get PDF
    Heterogeneity is a fact that plagues the characterization and application of many self-assembled biological constructs. The importance of obtaining particle homogeneity in biological assemblies is a critical goal, as bulk analysis tools often require identical species for reliable interpretation of the results—indeed, important tools of analysis such as x-ray diffraction typically require over 90% purity for effectiveness. This issue bears particular importance in the case of lipoproteins. Lipid-binding proteins known as apolipoproteins can self assemble with liposomes to form reconstituted high density lipoproteins (rHDLs) or nanolipoprotein particles (NLPs) when used for biotechnology applications such as the solubilization of membrane proteins. Typically, the apolipoprotein and phospholipids reactants are self assembled and even with careful assembly protocols the product often contains heterogeneous particles. In fact, size polydispersity in rHDLs and NLPs published in the literature are frequently observed, which may confound the accurate use of analytical methods. In this article, we demonstrate a procedure for producing a pure, monodisperse NLP subpopulation from a polydisperse self-assembly using size exclusion chromatography (SEC) coupled with high resolution particle imaging by atomic force microscopy (AFM). In addition, NLPs have been shown to self assemble both in the presence and absence of detergents such as cholate, yet the effects of cholate on NLP polydispersity and separation has not been systematically examined. Therefore, we examined the separation properties of NLPs assembled in both the absence and presence of cholate using SEC and native gel electrophoresis. From this analysis, NLPs prepared with and without cholate showed particles with well defined diameters spanning a similar size range. However, cholate was shown to have a dramatic affect on NLP separation by SEC and native gel electrophoresis. Furthermore, under conditions where different sized NLPs were not sufficiently separated or purified by SEC, AFM was used to deconvolute the elution pattern of different sized NLPs. From this analysis we were able to purify an NLP subpopulation to 90% size homogeneity by taking extremely fine elutions from the SEC. With this purity, we generate high quality NLP crystals that were over 100 μm in size with little precipitate, which could not be obtained utilizing the traditional size exclusion techniques. This purification procedure and the methods for validation are broadly applicable to other lipoprotein particles

    Signal-averaged P wave analysis for delineation of interatrial conduction – Further validation of the method

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>The study was designed to investigate the effect of different measuring methodologies on the estimation of P wave duration. The recording length required to ensure reproducibility in unfiltered, signal-averaged P wave analysis was also investigated. An algorithm for automated classification was designed and its reproducibility of manual P wave morphology classification investigated.</p> <p>Methods</p> <p>Twelve-lead ECG recordings (1 kHz sampling frequency, 0.625 <it>μ</it>V resolution) from 131 healthy subjects were used. Orthogonal leads were derived using the inverse Dower transform. Magnification (100 times), baseline filtering (0.5 Hz high-pass and 50 Hz bandstop filters), signal averaging (10 seconds) and bandpass filtering (40–250 Hz) were used to investigate the effect of methodology on the estimated P wave duration. Unfiltered, signal averaged P wave analysis was performed to determine the required recording length (6 minutes to 10 s) and the reproducibility of the P wave morphology classification procedure. Manual classification was carried out by two experts on two separate occasions each. The performance of the automated classification algorithm was evaluated using the joint decision of the two experts (i.e., the consensus of the two experts).</p> <p>Results</p> <p>The estimate of the P wave duration increased in each step as a result of magnification, baseline filtering and averaging (100 ± 18 vs. 131 ± 12 ms; P < 0.0001). The estimate of the duration of the bandpass-filtered P wave was dependent on the noise cut-off value: 119 ± 15 ms (0.2 <it>μ</it>V), 138 ± 13 ms (0.1 <it>μ</it>V) and 143 ± 18 ms (0.05 <it>μ</it>V). (P = 0.01 for all comparisons).</p> <p>The mean errors associated with the P wave morphology parameters were comparable in all segments analysed regardless of recording length (95% limits of agreement within 0 ± 20% (mean ± SD)). The results of the 6-min analyses were comparable to those obtained at the other recording lengths (6 min to 10 s).</p> <p>The intra-rater classification reproducibility was 96%, while the interrater reproducibility was 94%. The automated classification algorithm agreed with the manual classification in 90% of the cases.</p> <p>Conclusion</p> <p>The methodology used has profound effects on the estimation of P wave duration, and the method used must therefore be validated before any inferences can be made about P wave duration. This has implications in the interpretation of multiple studies where P wave duration is assessed, and conclusions with respect to normal values are drawn.</p> <p>P wave morphology and duration assessed using unfiltered, signal-averaged P wave analysis have high reproducibility, which is unaffected by the length of the recording. In the present study, the performance of the proposed automated classification algorithm, providing total reproducibility, showed excellent agreement with manually defined P wave morphologies.</p

    Swedish CLARIN activities

    Get PDF
    Proceedings of the NODALIDA 2009 workshop Nordic Perspectives on the CLARIN Infrastructure of Language Resources. Editors: Rickard Domeij, Kimmo Koskenniemi, Steven Krauwer, Bente Maegaard, Eiríkur Rögnvaldsson and Koenraad de Smedt. NEALT Proceedings Series, Vol. 5 (2009), 1-5. © 2009 The editors and contributors. Published by Northern European Association for Language Technology (NEALT) http://omilia.uio.no/nealt . Electronically published at Tartu University Library (Estonia) http://hdl.handle.net/10062/9207
    corecore