3,927 research outputs found

    Robust Object Detection with Real-Time Fusion of Multiview Foreground Silhouettes

    Get PDF

    Accommodation-Free Head Mounted Display with Comfortable 3D Perception and an Enlarged Eye-box.

    Get PDF
    An accommodation-free displays, also known as Maxwellian displays, keep the displayed image sharp regardless of the viewer's focal distance. However, they typically suffer from a small eye-box and limited effective field of view (FOV) which requires careful alignment before a viewer can see the image. This paper presents a high-quality accommodation-free head mounted display (aHMD) based on pixel beam scanning for direct image forming on retina. It has an enlarged eye-box and FOV for easy viewing by replicating the viewing points with an array of beam splitters. A prototype aHMD is built using this concept, which shows high definition, low colour aberration 3D augmented reality (AR) images with an FOV of 36°. The advantage of the proposed design over other head mounted display (HMD) architectures is that, due to the narrow, collimated pixel beams, the high image quality is unaffected by changes in eye accommodation, and the approach to enlarge the eye-box is scalable. Most importantly, such an aHMD can deliver realistic three-dimensional (3D) viewing perception with no vergence-accommodation conflict (VAC). It is found that viewing the accommodation-free 3D images with the aHMD presented in this work is comfortable for viewers and does not cause the nausea or eyestrain side effects commonly associated with conventional stereoscopic 3D or HMD displays, even for all day use

    Structure and optical properties of Lu <inf>2</inf>SiO <inf>5</inf>:Ce phosphor thin films

    Get PDF
    Luminescent, cerium doped Lu 2SiO 5 thin films with C2/c symmetry have been prepared by pulsed laser deposition (PLD) at temperatures much lower than the crystallization temperature (2150°C) of the corresponding bulk crystals. The PLD grown films show the typical luminescence resulting from the Ce 3+ 5d-4f transition. Maximum luminescence efficiency was observed for films prepared at an oxygen partial pressure of 200 mTorr at 600°C. These conditions reflect a balance between Ce 4+/Ce 3+ interconversion and the crystalline quality of the films. The results indicate that PLD offers a low temperature deposition technique for complex oxide phosphor materials. © 2006 American Institute of Physics

    Optical property and Stokes' shift of Zn <inf>1-x</inf>Cd <inf>x</inf>O thin films depending on Cd content

    Get PDF
    Ternary Zn1-x Cdx O films were grown on (0001) sapphire substrates by pulsed laser deposition. The energy band gap of Zn1-x Cdx O films decreases with increasing Cd content. An increase of Cd content also leads to the emission broadening, absorption edge broadening, and crystallinity degradation. The absorption edge and ultraviolet emission energy shift to lower energy from 3.357 eV to 3.295 eV and 3.338 eV to 3.157 eV, respectively, with increasing Cd content from 0.3% to 3% at 4 K. The Stokes' shift between the absorption and emission is observed and that indicates the increase of exciton localization with Cd content. © 2006 American Institute of Physics

    Microstructures and resistivity of cuprate/manganite bilayer deposited on SrTiO3 substrate

    Get PDF
    Thin Yba[SUB2]Cu[SUB3]O[SUB7-δ/La[SUB0.67]Ca[SUB0.33]MnO[SUB3] (YBCO/LCMO) films were grown on SrTiO[SUB3](STO)substrates by magnetron sputtering technique. The microstructures of the bilayers were characterized and a standard four-probe technique was applied to measure the resistivity of the samples. The interdiffusions at the YBCO/LCMO and LCMO/STO interfaces formed two transient layers with the thickness of about 3 and 2 nm, respectively. All the bilayers were well textured along the c axis. At low temperature, the superconductivity can only be observed when the thickness of YBCO is more than 25 nm. When the thickness of YBCO is less than 8 nm, the bilayers show only ferromagnetism. The superconductivity and ferromagnetism perhaps coexist in the bilayer with the YBCO thickness of 12.5 nm. These interesting properties are related to the interaction between spin polarized electrons in the manganites and the cooper pairs in the cuprates. © 2003 American Institute of Physics.published_or_final_versio

    Higher serum levels of periostin and the risk of exacerbations in moderate asthmatics

    Get PDF
    BACKGROUND: In asthma, exacerbations and poor disease control are linked to airway allergic inflammation. Serum periostin has been proposed as a systemic biomarker of eosinophilic inflammation. This pilot study aims at evaluating whether in patients with moderate asthma, higher baseline levels of serum periostin are associated with a greater risk of exacerbation. METHODS: Fifteen outpatients with moderate allergic asthma were recruited. Serum concentrations of periostin were assessed (ELISA) at baseline, and the frequency of asthma exacerbations was recorded during a one-year follow-up. RESULTS: Patients (M/F: 10/5, mean age of 47.6\u2009\ub1\u200911.0 years) had mean ACQ score of 5.5\u2009\ub1\u20094.2 and FEV1%pred of 81.9\u2009\ub1\u200921.7 %. Baseline serum levels of periostin did not correlate with lung function parameters, nor with the ACQ score (p 650.05 for all analyses). Five subjects (33 % of the study group) reported one or more exacerbations during the following year. Baseline serum levels of periostin were significantly higher in subjects who experienced one or more exacerbations during the one year period of follow-up, compared with subjects with no exacerbations: median serum periostin level was 4047 ng/ml (range: 2231 to 4889 ng/ml) and 222 ng/ml (range 28.2 to 1631 ng/ml) respectively; p\u2009=\u20090.001. CONCLUSION: The findings of the present pilot study could form the basis for the design of larger studies aiming at developing strategies to identify asthmatic patients at risk for exacerbations

    Genetic Variation in the Complete MgPa Operon and Its Repetitive Chromosomal Elements in Clinical Strains of Mycoplasma genitalium

    Get PDF
    Mycoplasma genitalium has been increasingly recognized as an important microbe not only because of its significant association with human genital tract diseases but also because of its utility as a model for studying the minimum set of genes necessary to sustain life. Despite its small genome, 4.7% of the total genome sequence is devoted to making the MgPa adhesin operon and its nine chromosomal repetitive elements (termed MgPars). The MgPa operon, along with 9 MgPars, is believed to play an important role in pathogenesis of M. genitalium infection and has also served as the main target for development of diagnostic tools. However, genetic variation in the complete MgPa operon and MgPars among clinical strains of M. genitalium has not been addressed. In this study we examined the genetic variation in the complete MgPa operon (approximately 8.5 kb) and full or partial MgPar sequences (0.4–2.6 kb) in 15 geographically diverse strains of M. genitalium. Extensive variation was present in four repeat regions of the MgPa operon (with homology to MgPars) among and within strains while the non-repeat regions (without homology to MgPars) showed low-level variation among strains and no variation within strains. MgPars showed significant variation among strains but were highly homogeneous within strains, supporting gene conversion as the likely recombination mechanism. When applying our sequence data to evaluate published MgPa operon-based diagnostic PCR assays and genotyping systems, we found that 11 of 19 primers contain up to 19 variable nucleotides and that the target for one of two typing systems is located in a hypervariable repeat region, suggesting the likelihood of false results with some of these assays. This study not only provides new insights into the role of the MgPa operon in the pathogenesis of M. genitalium infection but has important implications for the development of diagnostic tools

    Outcome-related metabolomic patterns from 1H/31P NMR after mild hypothermia treatments of oxygen–glucose deprivation in a neonatal brain slice model of asphyxia

    Get PDF
    Human clinical trials using 72 hours of mild hypothermia (32°C–34°C) after neonatal asphyxia have found substantially improved neurologic outcomes. As temperature changes differently modulate numerous metabolite fluxes and concentrations, we hypothesized that 1H/31P nuclear magnetic resonance (NMR) spectroscopy of intracellular metabolites can distinguish different insults, treatments, and recovery stages. Three groups of superfused neonatal rat brain slices underwent 45 minutes oxygen–glucose deprivation (OGD) and then were: treated for 3 hours with mild hypothermia (32°C) that began with OGD, or similarly treated with hypothermia after a 15-minute delay, or not treated (normothermic control group, 37°C). Hypothermia was followed by 3 hours of normothermic recovery. Slices collected at different predetermined times were processed, respectively, for 14.1 Tesla NMR analysis, enzyme-linked immunosorbent assay (ELISA) cell-death quantification, and superoxide production. Forty-nine NMR-observable metabolites underwent a multivariate analysis. Separated clustering in scores plots was found for treatment and outcome groups. Final ATP (adenosine triphosphate) levels, severely decreased at normothermia, were restored equally by immediate and delayed hypothermia. Cell death was decreased by immediate hypothermia, but was equally substantially greater with normothermia and delayed hypothermia. Potentially important biomarkers in the 1H spectra included PCr-1H (phosphocreatine in the 1H spectrum), ATP-1H (adenosine triphosphate in the 1H spectrum), and ADP-1H (adenosine diphosphate in the 1H spectrum). The findings suggest a potential role for metabolomic monitoring during therapeutic hypothermia

    Preparation of distilled and purified continuous variable entangled states

    Full text link
    The distribution of entangled states of light over long distances is a major challenge in the field of quantum information. Optical losses, phase diffusion and mixing with thermal states lead to decoherence and destroy the non-classical states after some finite transmission-line length. Quantum repeater protocols, which combine quantum memory, entanglement distillation and entanglement swapping, were proposed to overcome this problem. Here we report on the experimental demonstration of entanglement distillation in the continuous-variable regime. Entangled states were first disturbed by random phase fluctuations and then distilled and purified using interference on beam splitters and homodyne detection. Measurements of covariance matrices clearly indicate a regained strength of entanglement and purity of the distilled states. In contrast to previous demonstrations of entanglement distillation in the complementary discrete-variable regime, our scheme achieved the actual preparation of the distilled states, which might therefore be used to improve the quality of downstream applications such as quantum teleportation
    • …
    corecore