1,405 research outputs found

    CemOrange2 fusions facilitate multifluorophore subcellular imaging in C. elegans

    Get PDF
    Due to its ease of genetic manipulation and transparency, Caenorhabditis elegans (C. elegans) has become a preferred model system to study gene function by microscopy. The use of Aequorea victoria green fluorescent protein (GFP) fused to proteins or targeting sequences of interest, further expanded upon the utility of C. elegans by labeling subcellular structures, which enables following their disposition during development or in the presence of genetic mutations. Fluorescent proteins with excitation and emission spectra different from that of GFP accelerated the use of multifluorophore imaging in real time. We have expanded the repertoire of fluorescent proteins for use in C. elegans by developing a codon-optimized version of Orange2 (CemOrange2). Proteins or targeting motifs fused to CemOrange2 were distinguishable from the more common fluorophores used in the nematode; such as GFP, YFP, and mKate2. We generated a panel of CemOrange2 fusion constructs, and confirmed they were targeted to their correct subcellular addresses by colocalization with independent markers. To demonstrate the potential usefulness of this new panel of fluorescent protein markers, we showed that CemOrange2 fusion proteins could be used to: 1) monitor biological pathways, 2) multiplex with other fluorescent proteins to determine colocalization and 3) gain phenotypic knowledge of a human ABCA3 orthologue, ABT-4, trafficking variant in the C. elegans model organism

    On the Measurement of Energy Dissipation of Adhered Cells with the Quartz Microbalance with Dissipation Monitoring

    Get PDF
    We previously reported the finding of a linear correlation between the change of energy dissipation (ΔD) of adhered cells measured with the quartz crystal microbalance with dissipation monitoring (QCM-D) and the level of focal adhesions of the cells. To account for this correlation, we have developed a theoretical framework for assessing the ΔD-response of adhered cells. We rationalized that the mechanical energy of an oscillating QCM-D sensor coupled with a cell monolayer is dissipated through three main processes: the interfacial friction through the dynamic restructuring (formation and rupture) of cell-extracellular matrix (ECM) bonds, the interfacial viscous damping by the liquid trapped between the QCM-D sensor and the basal membrane of the cell layer, and the intracellular viscous damping through the viscous slip between the cytoplasm and stress fibers as well as among stress fibers themselves. Our modeling study shows that the interfacial viscous damping by the trapped liquid is the primary process for energy dissipation during the early stage of the cell adhesion, whereas the dynamic restructuring of cell-ECM bonds becomes more prevalent during the later stage of the cell adhesion. Our modeling study also establishes a positive linear correlation between the ΔD-response and the level of cell adhesion quantified with the number of cell-ECM bonds, which corroborates our previous experimental finding. This correlation with a wide well-defined linear dynamic range provides a much needed theoretical validation of the dissipation monitoring function of the QCM-D as a powerful quantitative analytical tool for cell study

    Active noise cancellation in a suspended interferometer

    Get PDF
    We demonstrate feed-forward vibration isolation on a suspended Fabry-Perot interferometer using Wiener filtering and a variant of the common Least Mean Square (LMS) adaptive filter algorithm. We compare the experimental results with theoretical estimates of the cancellation efficiency. Using data from the recent LIGO Science Run, we also estimate the impact of this technique on full scale gravitational wave interferometers. In the future, we expect to use this technique to also remove acoustic, magnetic, and gravitational noise perturbations from the LIGO interferometers. This noise cancellation technique is simple enough to implement in standard laboratory environments and can be used to improve SNR for a variety of high precision experiments.Comment: PACS numbers: 04.80.Nn, 95.55.Ym, 07.60.Ly, 42.62.E

    Metrology Camera System of Prime Focus Spectrograph for Subaru Telescope

    Get PDF
    The Prime Focus Spectrograph (PFS) is a new optical/near-infrared multi-fiber spectrograph designed for the prime focus of the 8.2m Subaru telescope. PFS will cover a 1.3 degree diameter field with 2394 fibers to complement the imaging capabilities of Hyper SuprimeCam. To retain high throughput, the final positioning accuracy between the fibers and observing targets of PFS is required to be less than 10um. The metrology camera system (MCS) serves as the optical encoder of the fiber motors for the configuring of fibers. MCS provides the fiber positions within a 5um error over the 45 cm focal plane. The information from MCS will be fed into the fiber positioner control system for the closed loop control. MCS will be located at the Cassegrain focus of Subaru telescope in order to to cover the whole focal plane with one 50M pixel Canon CMOS camera. It is a 380mm Schmidt type telescope which generates a uniform spot size with a 10 micron FWHM across the field for reasonable sampling of PSF. Carbon fiber tubes are used to provide a stable structure over the operating conditions without focus adjustments. The CMOS sensor can be read in 0.8s to reduce the overhead for the fiber configuration. The positions of all fibers can be obtained within 0.5s after the readout of the frame. This enables the overall fiber configuration to be less than 2 minutes. MCS will be installed inside a standard Subaru Cassgrain Box. All components that generate heat are located inside a glycol cooled cabinet to reduce the possible image motion due to heat. The optics and camera for MCS have been delivered and tested. The mechanical parts and supporting structure are ready as of spring 2016. The integration of MCS will start in the summer of 2016.Comment: 11 pages, 15 figures. SPIE proceeding. arXiv admin note: text overlap with arXiv:1408.287

    Metrology Camera System of Prime Focus Spectrograph for Subaru Telescope

    Get PDF
    The Prime Focus Spectrograph (PFS) is a new optical/near-infrared multi-fiber spectrograph designed for the prime focus of the 8.2m Subaru telescope. The metrology camera system of PFS serves as the optical encoder of the COBRA fiber motors for the configuring of fibers. The 380mm diameter aperture metrology camera will locate at the Cassegrain focus of Subaru telescope to cover the whole focal plane with one 50M pixel Canon CMOS sensor. The metrology camera is designed to provide the fiber position information within 5{\mu}m error over the 45cm focal plane. The positions of all fibers can be obtained within 1s after the exposure is finished. This enables the overall fiber configuration to be less than 2 minutes.Comment: 10 pages, 12 figures, SPIE Astronomical Telescopes and Instrumentation 201

    Clues to the Metallicity Distribution in the Galactic Bulge: Abundances in OGLE-2007_BLG-349S

    Get PDF
    We present an abundance analysis based on high dispersion and high signal-to-noise ratio Keck spectra of a very highly microlensed Galactic bulge dwarf, OGLE-2007-BLG-349S, with Teff ~ 5400 K. The amplification at the time the spectra were taken ranged from 350 to 450. This bulge star is highly enhanced in metallicity with [Fe/H] = +0.51 \pm 0.09 dex. The abundance ratios for the 28 species of 26 elements for which features could be detected in the spectra are solar. In particular, there is no evidence for enhancement of any of the alpha-elements including O and Mg. We conclude that the high [Fe/H] seen in this star, when combined with the equally high [Fe/H] derived in previous detailed abundance analysis of two other Galactic bulge dwarfs, both also microlensed, implies that the median metallicity in the Galactic bulge is very high. We thus infer that many previous estimates of the metallicity distribution in the Galactic bulge have substantially underestimated the mean Fe-metallicity there due to sample bias, and suggest a candidate mechanism for such. If our conjecture proves valid, it may be necessary to update the calibrations for the algorithms used by many groups to interpret spectra and broad band photometry of the integrated light of very metal-rich old stellar populations, including luminous elliptical galaxies.Comment: version accepted by the ApJ, minor changes from originl submission, 38 pages with 6 figures (2 in color

    HIV Testing and Management: Findings from a National Sample of Asian/Pacific Islander Men Who Have Sex with Men

    Get PDF
    We examined reasons for and barriers to participating in HIV voluntary counseling and testing for Asian/Pacific Islander (A/PI) men who have sex with men (MSM) in the U.S

    Measuring Coverage in MNCH:A Validation Study Linking Population Survey Derived Coverage to Maternal, Newborn, and Child Health Care Records in Rural China

    Get PDF
    Accurate data on coverage of key maternal, newborn, and child health (MNCH) interventions are crucial for monitoring progress toward the Millennium Development Goals 4 and 5. Coverage estimates are primarily obtained from routine population surveys through self-reporting, the validity of which is not well understood. We aimed to examine the validity of the coverage of selected MNCH interventions in Gongcheng County, China.We conducted a validation study by comparing women's self-reported coverage of MNCH interventions relating to antenatal and postnatal care, mode of delivery, and child vaccinations in a community survey with their paper- and electronic-based health care records, treating the health care records as the reference standard. Of 936 women recruited, 914 (97.6%) completed the survey. Results show that self-reported coverage of these interventions had moderate to high sensitivity (0.57 [95% confidence interval (CI): 0.50-0.63] to 0.99 [95% CI: 0.98-1.00]) and low to high specificity (0 to 0.83 [95% CI: 0.80-0.86]). Despite varying overall validity, with the area under the receiver operating characteristic curve (AUC) ranging between 0.49 [95% CI: 0.39-0.57] and 0.90 [95% CI: 0.88-0.92], bias in the coverage estimates at the population level was small to moderate, with the test to actual positive (TAP) ratio ranging between 0.8 and 1.5 for 24 of the 28 indicators examined. Our ability to accurately estimate validity was affected by several caveats associated with the reference standard. Caution should be exercised when generalizing the results to other settings.The overall validity of self-reported coverage was moderate across selected MNCH indicators. However, at the population level, self-reported coverage appears to have small to moderate degree of bias. Accuracy of the coverage was particularly high for indicators with high recorded coverage or low recorded coverage but high specificity. The study provides insights into the accuracy of self-reports based on a population survey in low- and middle-income countries. Similar studies applying an improved reference standard are warranted in the future

    The Association between Serum Serine and Glycine and Related-Metabolites with Pancreatic Cancer in a Prospective Cohort Study

    Get PDF
    Background: Serine and glycine play an important role in the folate-dependent one-carbon metabolism. The metabolism of serine and glycine has been shown to be associated with cancer cell proliferation. No prior epidemiologic study has investigated the associations for serum levels of serine and glycine with pancreatic cancer risk. Methods: We conducted a nested case-control study involved 129 incident pancreatic cancer cases and 258 individually matched controls within a prospective cohort study of 18,244 male residents in Shanghai, China. Glycine and serine and related metabolites in pre-diagnostic serum were quantified using gas chromatography-tandem mass spectrometry. A conditional logistic regression method was used to evaluate the associations for serine, glycine, and related metabolites with pancreatic cancer risk with adjustment for potential confounders. Results: Odds ratios (95% confidence intervals) of pancreatic cancer for the highest quartile of serine and glycine were 0.33 (0.14–0.75) and 0.25 (0.11–0.58), respectively, compared with their respective lowest quartiles (both p’s < 0.01). No significant association with risk of pancreatic cancer was observed for other serine- or glycine related metabolites including cystathionine, cysteine, and sarcosine. Conclusion: The risk of pancreatic cancer was reduced by more than 70% in individuals with elevated levels of glycine and serine in serum collected, on average, more than 10 years prior to cancer diagnosis in a prospectively designed case-control study. These novel findings support a protective role of serine and glycine against the development of pancreatic cancer in humans that might have an implication for cancer prevention.publishedVersio
    • …
    corecore