441 research outputs found

    Effects of Metformin on Spontaneous and Clomiphene-Induced Ovulation in the Polycystic Ovary Syndrome

    Get PDF
    ABSTRACT Background Obese women with the polycystic ovary syndrome are relatively unresponsive to the induction of ovulation by clomiphene. We hypothesized that reducing insulin secretion by administering metformin would increase the ovulatory response to clomiphene. Methods We performed oral glucose-tolerance tests before and after the administration of 500 mg of metformin or placebo three times daily for 35 days in 61 obese women with the polycystic ovary syndrome. Women who did not ovulate spontaneously were then given 50 mg of clomiphene daily for five days while continuing to take metformin or placebo. Serum progesterone was measured on days 14, 28, 35, 44, and 53, and ovulation was presumed to have occurred if the concentration exceeded 8 ng per milliliter (26 nmol per liter) on any of these days. Results Twenty-one women in the metformin group and 25 women in the placebo group were given clomiphene because they did not ovulate spontaneously during the first phase of the study. Among the 21 women given metformin plus clomiphene, the mean (±SE) area under the serum insulin curve after oral glucose administration decreased from 6745±2021 to 3479±455 µU per milliliter per minute (40.5±12.1 to 20.9±2.7 nmol per liter per minute, P=0.03), but it did not change significantly in the 25 women given placebo plus clomiphene. Nineteen of the 21 women (90 percent) who received metformin plus clomiphene ovulated (mean peak serum progesterone concentration, 23.8±3.4 ng per milliliter [7.6±10.9 nmol per liter]). Two of the 25 women (8 percent) who received placebo plus clomiphene ovulated (P\u3c0.001). Overall, 31 of the 35 women (89 percent) treated with metformin ovulated spontaneously or in response to clomiphene, as compared with 3 of the 26 women (12 percent) treated with placebo. Conclusions The ovulatory response to clomiphene can be increased in obese women with the polycystic ovary syndrome by decreasing insulin secretion with metformin. (N Engl J Med 1998;338:1876-80.

    Recurrent mutations of BRCA1, BRCA2 and PALB2 in the population of breast and ovarian cancer patients in Southern Poland

    Get PDF
    Background Mutations in the BRCA1, BRCA2 and PALB2 genes are well-established risk factors for the development of breast and/or ovarian cancer. The frequency and spectrum of mutations in these genes has not yet been examined in the population of Southern Poland. Methods We examined the entire coding sequences of the BRCA1 and BRCA2 genes and genotyped a recurrent mutation of the PALB2 gene (c.509_510delGA) in 121 women with familial and/or early-onset breast or ovarian cancer from Southern Poland. Results A BRCA1 mutation was identified in 11 of 121 patients (9.1 %) and a BRCA2 mutation was identified in 10 of 121 patients (8.3 %). Two founder mutations of BRCA1 accounted for 91 % of all BRCA1 mutation carriers (c.5266dupC was identified in six patients and c.181 T > G was identified in four patients). Three of the seven different BRCA2 mutations were detected in two patients each (c.9371A > T, c.9403delC and c.1310_1313delAAGA). Three mutations have not been previously reported in the Polish population (BRCA1 c.3531delT, BRCA2 c.1310_1313delAAGA and BRCA2 c.9027delT). The recurrent PALB2 mutation c.509_510delGA was identified in two patients (1.7 %). Conclusions The standard panel of BRCA1 founder mutations is sufficiently sensitive for the identification of BRCA1 mutation carriers in Southern Poland. The BRCA2 mutations c.9371A > T and c.9403delC as well as the PALB2 mutation c.509_510delGA should be included in the testing panel for this population

    Perfusion CT is a valuable diagnostic method for prostate cancer: a prospective study of 94 patients

    Get PDF
    Purpose: The aim of this study is to assess the usefulness of perfusion computer tomography (pCT) in prostate cancer (PCa) diagnostics. Copyright:Materials and Methods: 94 patients with biopsy-proven PCa were enrolled in the study. Dynamic pCT of the prostate gland was performed for 50 seconds after an intravenous injection of contrast medium. Blood flow (BF), blood volume (BV), mean transit time (MTT) and permeability surface area product (PS) were computed in the suspected PCa area and in normal prostatic tissue.Results: PCa was visible in pCT in 90 of the 94 examined patients as a focal peripheral CT enhancement. When PCa was located in the peripheral zone (PZ), it was visible on perfusion maps, mostly showing an early peak followed by wash-out. The average values of all perfusion parameters were higher for tumour than for normal prostate tissue (p 7). In high-grade PCa, the mean BF value was significantly higher (p = 0.001) than the mean value of BF low- and medium-grade PCa (p = 0.011). Similar results were obtained regarding the mean values of BV; the more aggressive the cancer grade, the higher the mean BV value (p = 0.04).Conclusion: CT quantitative perfusion imaging allows PCa to be distinguished from normal prostate tissue. The highest values for BF and BV were observed in the most aggressive PCa grade

    Corrosion behaviour of porous Ti intended for biomedical applications

    Get PDF
    Porous Ti implants are being developed inorder to reduce the biomechanical mismatch between theimplant and the bone, as well as increasing the osseointegrationby improving the bone in-growth. Most of the focusin the literature has been on the structural, biological andmechanical characterization of porous Ti whereas there islimited information on the electrochemical characterization.Therefore, the present work aims to study the corrosionbehaviour of porous Ti having 30 and 50 % ofnominal porosity, produced by powder metallurgy routeusing the space holder technique. The percentage, size anddistribution of the pores were determined by image analysis.Electrochemical tests consisting of potentiodynamicpolarization and electrochemical impedance spectroscopywere performed in 9 g/L NaCl solution at body temperature.Electrochemical studies revealed that samples presenteda less stable oxide film at increased porosity, morespecifically, the complex geometry and the interconnectivityof the pores resulted in formation of less protectiveoxide film in the pores.This study was supported by FCT with the reference project UID/EEA/04436/2013, by FEDER funds through the COMPETE 2020 – Programa Operacional Competitividade e Internacionalizac¸a˜o (POCI) with the reference project POCI-01-0145- FEDER-006941, Programa de Acc¸o˜es Universita´rias Integradas LusoFrancesas’ (PAUILF TC-12_14), and The Calouste Gulbenkian Foundation through ‘‘Programa de Mobilidade Acade´mica para Professores’’. The authors would also like to acknowledge Prof. Ana Senos (University of Aveiro) and Prof. Jose´ Carlos Teixeira (University of Minho) for the provision of the characterization facilities.info:eu-repo/semantics/publishedVersio

    Induction of cancer-specific cytotoxicity towards human prostate and skin cells using quercetin and ultrasound

    Get PDF
    Bioflavonoids, such as quercetin, have recently emerged as a new class of chemotherapeutic drugs for the treatment of various cancer types, but are marred by their low potency and poor selectivity. We report that a short application of low-frequency ultrasound selectively sensitises prostate and skin cancer cells against quercetin. Pretreatment of cells with ultrasound (20 kHz, 2 W cm−2, 60 s) selectively induced cytotoxicity in skin and prostate cancer cells, while having minimal effect on corresponding normal cell lines. About 90% of the viable skin cancer cell population was lost within 48 h after ultrasound-quercetin (50 μM) treatment. Ultrasound reduced the LC50 of quercetin for skin cancer cells by almost 80-fold, while showing no effect on LC50 for nonmalignant skin cells
    • …
    corecore