32 research outputs found

    Gaze following is modulated by expectations regarding others’ action goals

    Get PDF
    Humans attend to social cues in order to understand and predict others' behavior. Facial expressions and gaze direction provide valuable information to infer others' mental states and intentions. The present study examined the mechanism of gaze following in the context of participants' expectations about successive action steps of an observed actor. We embedded a gaze-cueing manipulation within an action scenario consisting of a sequence of naturalistic photographs. Gaze-induced orienting of attention (gaze following) was analyzed with respect to whether the gaze behavior of the observed actor was in line or not with the action-related expectations of participants (i.e., whether the actor gazed at an object that was congruent or incongruent with an overarching action goal). In Experiment 1, participants followed the gaze of the observed agent, though the gaze-cueing effect was larger when the actor looked at an action-congruent object relative to an incongruent object. Experiment 2 examined whether the pattern of effects observed in Experiment 1 was due to covert, rather than overt, attentional orienting, by requiring participants to maintain eye fixation throughout the sequence of critical photographs (corroborated by monitoring eye movements). The essential pattern of results of Experiment 1 was replicated, with the gaze-cueing effect being completely eliminated when the observed agent gazed at an action-incongruent object. Thus, our findings show that covert gaze following can be modulated by expectations that humans hold regarding successive steps of the action performed by an observed agent

    Resistencia a la flexión de la guadua agustifolia kunt a escala natural.

    Get PDF
    En los laboratorios de productos forestales y en el de construcciones rurales de la Universidad Nacional de Colombia Sede Medellín, se realizaron dieciocho (18) ensayos de flexión estática a escala natural con luces entre 2,50 y 3,50 metros de la sobrebasa del elemento, las cuales son las más utilizadas y recomendadas para este tipo de esfuerzo, donde el material seleccionado corresponde a la especie Guadua (Angustifolia kunth), colectada en la Finca Cotové ubicada en Santafé de Antioquia y cuya zona de vida corresponde a un bosque seco tropical (bs-t). Las pruebas fueron realizadas basadas en las Normas COPANT 455 (1972) para selección y colección de muestras de madera, 459 acondicionamiento de maderas destinadas a ensayos físicos y mecánicos y 460 para la determinación del contenido de humedad y las normas de la American Society for Testing and Materials, 1975. Estas normas son empleadas para maderas macizas, por lo tanto debieron ser ajustadas a las condiciones particulares de la guadua circular hueca de acuerdo a la metodología utilizada por González y Díaz 1992. Este trabajo presenta los resultados de las ecuaciones de diseños para elementos de guadua sometidos a flexión estática, los valores de esfuerzos unitarios en el límite proporcional (RLP), módulo de elasticidad (MOE) y el esfuerzo de rotura (MOR), los cuales fueron comparados con los valores obtenidos por González y Días, 1.992, cuyos ensayos fueron hechos bajo probetas, obteniéndose variaciones menores del 7% entre estos, y a la vez se hallaron unos coeficientes de varianza con rangos entre el 20 y el 30% para los parámetros establecidos los cuales fueron considerados aceptables. Para la obtención de los parámetros anteriores se tuvieron en cuenta aspectos como la longitud, diámetro promedio, espesor de las paredes medidas en los extremos, el contenido de humedad en base seca y la carga de falla del elemento. Finalmente, se recomienda utilizar las ecuaciones de diseño obtenida con elementos cuyos parámetros se encuentren entre los siguientes rangos, con el fin de garantizar un mayor factor de seguridad a la hora de aplicar dichas ecuaciones, ya que estos son considerados de gran importancia al momento de realizar cálculos estructurales con este tipo de material alternativo de construcción: longitud 2,50 -3,00 m; espesor de las paredes 0,70-1,40 cm; humedad en base seca 7,0 - 11,5 %; diámetro promedio 8,0 - 12,0 cm

    Thermal environment in two broiler barns during the first three weeks of age

    Get PDF
    ABSTRACT The objective of this research was to evaluate the internal thermal environment of two broiler barns featuring different ventilation systems representative of Brazilian and South American poultry production industry: (a) a negative-pressure tunnel and (b) a positive-pressure lateral ventilation system. Environmental parameters such as dry bulb temperature, relative humidity and temperature-humidity index were assessed; temperature maps for day and night average conditions were determined for the first three weeks of life. Better uniformity of the thermal environment and comfort conditions inside the negative-pressure tunnel were found

    Simulation of the internal environment of a post-harvest installation and a solar dryer of Coffee

    No full text
    This study aimed to make a simulation of the internal environment of an installations for coffee post-harvest and a parabolic solar dryer, specifically analyzing the effect of natural ventilation on the temperature and relative humidity inside these buildings. The ventilated coffee-processing plant and the solar dryer with the largest natural ventilation area showed the best results to preserve the quality of coffee grain.Este trabalho propôs, como objetivo, fazer a simulação do ambiente interno de uma instalação de beneficiamento de café e de um secador solar parabólico analisando especificamente o efeito da ventilação natural sobre a temperatura e a umidade relativa do ar no interior dessas construções. A instalação de beneficiamento de café ventilada e o secador solar com a maior área de ventilação natural apresentaram os melhores resultados para conservar a qualidade do grão de café

    Simulation of the internal environment of a post-harvest installation and a solar dryer of coffee

    No full text
    ABSTRACT This study aimed to make a simulation of the internal environment of an installations for coffee post-harvest and a parabolic solar dryer, specifically analyzing the effect of natural ventilation on the temperature and relative humidity inside these buildings. The ventilated coffee-processing plant and the solar dryer with the largest natural ventilation area showed the best results to preserve the quality of coffee grain

    Emissão de amônia de galpões de frangos de corte com ventilação natural e mecânica no Brasil

    No full text
    This study was conducted with the aim of monitoring NH3 emissions from a mechanically and a naturally ventilated broiler house (MVB and NVB, respectively) and calculate their ammonia emission factors (fNH3). Bird stocking density was 13.5 and 11.1 birds m-2 for the MVB and NVB, respectively. The marketing age was 43 days and bedding consisted of dried coffee husks in its first time of use. Ventilation rates were calculated with the metabolic carbon dioxide mass balance method. Values of fNH3 were 0.32 ± 0.10 and 0.27 ± 0.07 g bird-1 d-1for the MVB and NVB, respectively, and are in agreement to what was presented in other studies performed under similar conditions. The fNH3 estimated on yearly basis was 58 g bird-place-1 year-1. It was concluded that the different types of ventilation system between the studied broiler barns did not significantly affect emissions in the modeling process. The results obtained help providing reliable methodology for the determination of a solid database on NH3 emission factors for tropical conditions that can be used for future inventories, when performed in a sufficient number of barns that is representative for the Brazilian scenario.</p

    Calidad del aire en galpón avícola con ventilación natural durante la fase de pollitos

    No full text
    RESUMEN Los pollos de engorde durante la primera fase deben estar protegidos del estrés por frio, especialmente en el inverno, noches y madrugadas frías. Para proteger a los animales, los avicultores han utilizado diferentes estrategias, entre ellas está el uso de varias capas de cortinas para aumentar el nivel de aislamiento térmico y disminuir las pérdidas de calor, disminuyendo también la permeabilidad con el aire externo. En este contexto, es importante dar especial atención a la calidad del aire interno de los galpones avícolas como parte de una producción bajo parámetros de bienestar animal. El presente estudio fue realizado en el municipio de Barbacena, MG, en Brasil, y tuvo como objetivo evaluar la calidad del aire al nivel de los pollos y los trabajadores, específicamente de las concentraciones de amoniaco, dióxido de carbono y monóxido de carbono, en un galpón avícola naturalmente ventilado durante la primera fase de vida de pollos de engorde en el período de inverno, y la influencia del nivel de aislamiento con cortinas laterales sobre las concentraciones de amoniaco. Durante la primera semana experimental, los niveles de amoniaco sobrepasaron los valores aceptables, y se encontró diferencia estadística entre las concentraciones de amoniaco para los diferentes niveles de aislamiento con cortinas laterales

    A simple methodology to measure ammonia flux generated in naturally ventilated poultry houses

    No full text
    Antecedentes: a quantificação da taxa de emissão de poluentes, tais como a amônia (NH3) em instalações animais abertas e com ventilação natural, como são usadas na América do Sul, é um desafio, em parte devido a dificuldade de determinação da taxa de ventilação. Assim, alguns métodos têm sido desenvolvidos para reduzir esta dificuldade, mas a maioria deles são onerosos e complexos, inviabilizando a sua aplicação. Objetivo: o presente trabalho objetivou-se adaptar e validar o método Saraz para determinar o fluxo de NH3 (SMDAE) emitida dos galpões avícolas submetidos à ventilação natural. Métodos: para fazer a validação do método proposto, o fluxo de amônia (ER; massa de NH3 gerada por unidade de tempo) foi comparada com os resultados obtidos por meio de equação ajustada proposta por Wheeler et al. (2006; ER2). Para a avaliação proposta, os valores obtidos com os dois métodos usados (SMDAE e ER2) foram comparados mediante analise estadística. Resultados: o método proposto mostrou poder ser usado com confiabilidade em condições de ventilação natural com ventos maiores que 0,1 m/s-1 e concentrações de NH3 maiores que 1 ppm. Conclusão:o método apresentou uma boa correlação entre os valores encontrados pelo método proposto e aqueles obtidos na equação característica para o cálculo de emissões a qual é baseada no conhecimento da concentração de NH3, velocidade e temperatura do ar, o que torna o método como uma alternativa viável para fazer inventários de amônia em instalações aviárias com ventilação natural.Antecedentes: la cuantificación de la tasa de emision de contaminantes tales como el amoniaco (NH3) en instalaciones de producción animal con ventilación natural como las utilizadas en América del Sur es un reto, en parte debido a la dificultad para determinar la tasa de ventilación. Algunos métodos han sido desarrollados para reducir esta dificultad, pero la mayoría de ellos son costosos y complejos, lo que impide su aplicación. Objetivo: el presente trabajo tuvo como objetivo adaptar y validar el método Saraz para calcular el flujo de amoniaco (SMDAE) generado en galpones avícolas con ventilación natural. Métodos: para validar el método propuesto, el flujo de amoniaco (ER; masa de NH3 emitida por unidad de tiempo) fue comparado con los resultados obtenidos por medio de la ecuación ajustada propuesta por Wheeler et al. (2006; ER2). Para su evaluación, los valores obtenidos con los dos métodos (SMDAE y ER2) fueron comparados mediante análisis estadístico. Resultados: el método propuesto se considera adecuado para ser utilizado en las condiciones de ventilación natural con vientos superiores a 0,1 m/s-1 y concentraciones de NH3 superiores a 1 ppm. Conclusión: el método presentó una buena correlación entre los valores determinados y los obtenidos mediante la ecuación estandar para el cálculo de emisiones basada en la concentración de NH3, velocidad del aire y temperatura, lo que lo convierte en una alternativa confiable para hacer inventarios de amoníaco en instalaciones avícolas con ventilación natural.Background: quantifying the rate of pollutant emissions, such as ammonia (NH3), from naturally ventilated animal production buildings in structures, such as those used in South America, is challenging mainly due to the challenge of determining building ventilation rate. Some methods have been developed to reduce this difficulty, but most are costly and complex, preventing their implementation.. Objective: the present work aimed to adapt and validate the Saraz method for the determination of ammonia emissions (SMDAE) from naturally ventilated poultry houses. Methods: to validate the proposed method, the ammonia emission rate (ER; NH3 mass emitted per unit time) was computed using the adjusted equation proposed by Wheeler et al.(2006; ER2). For evaluation purposes, the data obtained from the two measuring methods (SMDAE and ER2)were statistically analyzed. Results: the proposed method was considered adequate for use under conditions of natural ventilation with wind speeds greater than 0.1 m/s-1 and NH3 concentrations greater than 1 ppm. Conclusion: the method demonstrated a good correlation between its values and those obtained by the standard equation for calculating emissions based on NH3 concentration, air speed and temperature, which makes the Saraz method a reliable approach to develop ammonia inventories for naturally-ventilated poultry facilities

    Calidad del aire en galpón avícola con ventilación natural durante la fase de pollitos

    No full text
    RESUMEN Los pollos de engorde durante la primera fase deben estar protegidos del estrés por frio, especialmente en el inverno, noches y madrugadas frías. Para proteger a los animales, los avicultores han utilizado diferentes estrategias, entre ellas está el uso de varias capas de cortinas para aumentar el nivel de aislamiento térmico y disminuir las pérdidas de calor, disminuyendo también la permeabilidad con el aire externo. En este contexto, es importante dar especial atención a la calidad del aire interno de los galpones avícolas como parte de una producción bajo parámetros de bienestar animal. El presente estudio fue realizado en el municipio de Barbacena, MG, en Brasil, y tuvo como objetivo evaluar la calidad del aire al nivel de los pollos y los trabajadores, específicamente de las concentraciones de amoniaco, dióxido de carbono y monóxido de carbono, en un galpón avícola naturalmente ventilado durante la primera fase de vida de pollos de engorde en el período de inverno, y la influencia del nivel de aislamiento con cortinas laterales sobre las concentraciones de amoniaco. Durante la primera semana experimental, los niveles de amoniaco sobrepasaron los valores aceptables, y se encontró diferencia estadística entre las concentraciones de amoniaco para los diferentes niveles de aislamiento con cortinas laterales
    corecore