4,590 research outputs found
Cardiovascular magnetic resonance-guided right heart catheterization in a conventional CMR environment - predictors of procedure success and duration in pulmonary artery hypertension
Background
Cardiovascular magnetic resonance imaging (CMR) is valuable for the investigation and management of pulmonary artery hypertension (PAH), but the direct measurement of pulmonary hemodynamics by right heart catheterization is still necessary. CMR-guided right heart catheterization (CMR-RHC) combines the benefits of CMR and invasive cardiac catheterization, but its feasibility in patients with acquired PAH has not been established. The aims of this study are to: (1) demonstrate the feasibility of CMR-RHC in patients being assessed for PAH in a conventional diagnostic CMR scanner room; (2) determine the predictors of (i) procedure duration, and (ii) procedural failure or technical difficulty as determined by the adjunctive need for a guidewire.
Methods
Fifty patients investigated for suspected or known PH underwent CMR-RHC. Durations of separate procedural components were recorded, including time taken to pass the catheter from the femoral vein to a stable wedge position (procedure time) and total time the patient spent in the CMR department (department time). Associations between procedural failure/guidewire usage and hemodynamic/CMR measures were assessed using logistic regression. Relationships between procedure times and hemodynamic/CMR measures were evaluated using Spearman’s correlation coefficient.
Results
A full CMR-RHC study was successfully completed in 47 (94%) patients. CMR-conditional guidewires were used in 6 (12%) patients. Metrics associated with guidewire use/procedural failure were higher mean pulmonary artery (PA) pressures (mPAP: OR = 1.125, p = 0.018), right heart dilatation (right ventricular (RV) end-systolic volume (RVESV): OR = 1.028, p = 0.018), RV hypertrophy (OR = 1.050, p = 0.0067) and RV ejection fraction (EF) (OR = 0.914, p = 0.014). Median catheter and department times were 3.6 (2.0–7.7) minutes and 60.0 (54.0–68.5) minutes, respectively. All procedure times became significantly shorter with increasing procedural experience (p < 0.05). Catheterization time was also associated with PH severity (RV systolic pressure: rho = 0.46, p = 0.0013) and increasing RV end-systolic volume (RVESV: rho = 0.41, p = 0.0043), hypertrophy (rho = 0.43, p = 0.0025) and dysfunction (RVEF: rho = − 0.32, p = 0.031).
Conclusions
This study demonstrates that CMR-RHC using standard technology can be incorporated into routine clinical practice for the investigation of PAH. Procedural failure was rare but more likely in patients with severe PAH. Procedure time is clinically acceptable and increases with worsening PAH severity
Aluminum exposure at human dietary levels promotes vascular dysfunction and increases blood pressure in rats: a concerted action of NAD(P)H oxidase and COX-2
Abstract Aluminum (Al) is a non-essential metal and a significant environmental contaminant and is associated with a number of human diseases including cardiovascular disease. We investigated the effects of Al exposure at doses similar to human dietary levels on the cardiovascular system over a 60 day period. Wistar male rats were divided into two major groups and received orally: 1) Low aluminum level − rats were subdivided and treated for 60 days as follows: a) Untreated − ultrapure water; b) AlCl3 at a dose of 8.3 mg/kg bw for 60 days, representing human Al exposure by diet; and 2) High aluminum level − rats were subdivided and treated for 42 days as follows: C) Untreated − ultrapure water; d) AlCl3 at 100 mg/kg bw for 42 days, representing a high level of human exposure to Al. Effects on systolic blood pressure (SBP) and vascular function of aortic and mesenteric resistance arteries (MRA) were studied. Endothelium and smooth muscle integrity were evaluated by concentration-response curves to acetylcholine (ACh) and sodium nitroprusside. Vasoconstrictor responses to phenylephrine (Phe) in the presence and absence of endothelium and in the presence of the NOS inhibitor L-NAME, the potassium channels blocker TEA, the NAD(P)H oxidase inhibitor apocynin, superoxide dismutase (SOD), the non-selective COX inhibitor indomethacin and the selective COX-2 inhibitor NS 398 were analyzed. Vascular reactive oxygen species (ROS), lipid peroxidation and total antioxidant capacity, were measured. The mRNA expressions of eNOS, NAD(P)H oxidase 1 and 2, SOD1, COX-2 and thromboxane A2 receptor (TXA-2 R) were also investigated. Al exposure at human dietary levels impaired the cardiovascular system and these effects were almost the same as Al exposure at much higher levels. Al increased SBP, decreased ACh-induced relaxation, increased response to Phe, decreased endothelial modulation of vasoconstrictor responses, the bioavailability of nitric oxide (NO), the involvement of potassium channels on vascular responses, as well as increased ROS production from NAD(P)H oxidase and contractile prostanoids mainly from COX-2 in both aorta and mesenteric arteries. Al exposure increased vascular ROS production and lipid peroxidation as well as altered the antioxidant status in aorta and MRA. Al decreased vascular eNOS and SOD1 mRNA levels and increased the NAD(P)H oxidase 1, COX-2 and TXA-2 R mRNA levels. Our results point to an excess of ROS mainly from NAD(P)H oxidase after Al exposure and the increased vascular prostanoids from COX-2 acting in concert to decrease NO bioavailability, thus inducing vascular dysfunction and increasing blood pressure. Therefore, 60-day chronic exposure to Al, which reflects common human dietary Al intake, appears to pose a risk for the cardiovascular system
Perturbations of Gauss-Bonnet Black Strings in Codimension-2 Braneworlds
We derive the Lichnerowicz equation in the presence of the Gauss-Bonnet term.
Using the modified Lichnerowicz equation we study the metric perturbations of
Gauss-Bonnet black strings in Codimension-2 Braneworlds.Comment: 26 pages, no figures, clarifying comments and one reference added, to
be published in JHE
Chern-Simons black holes: scalar perturbations, mass and area spectrum and greybody factors
We study the Chern-Simons black holes in d-dimensions and we calculate
analytically the quasi-normal modes of the scalar perturbations and we show
that they depend on the highest power of curvature present in the Chern-Simons
theory. We obtain the mass and area spectrum of these black holes and we show
that they have a strong dependence on the topology of the transverse space and
they are not evenly spaced. We also calculate analytically the reflection and
transmission coefficients and the absorption cross section and we show that at
low frequency limit there is a range of modes which contributes to the
absorption cross section.Comment: 19 pages, 18 figures, the title has been changed to reflect the
addition of an another section on the reflection, transmission coefficients
and absorption cross sections of the Chern-Simons black holes. Version to be
published in JHE
Does inter-vertebral range of motion increase after spinal manipulation? A prospective cohort study.
Background: Spinal manipulation for nonspecific neck pain is thought to work in part by improving inter-vertebral range of motion (IV-RoM), but it is difficult to measure this or determine whether it is related to clinical outcomes.
Objectives: This study undertook to determine whether cervical spine flexion and extension IV-RoM increases after a course of spinal manipulation, to explore relationships between any IV-RoM increases and clinical outcomes and to compare palpation with objective measurement in the detection of hypo-mobile segments.
Method: Thirty patients with nonspecific neck pain and 30 healthy controls matched for age and gender received quantitative fluoroscopy (QF) screenings to measure flexion and extension IV-RoM (C1-C6) at baseline and 4-week follow-up between September 2012-13. Patients received up to 12 neck manipulations and completed NRS, NDI
and Euroqol 5D-5L at baseline, plus PGIC and satisfaction questionnaires at follow-up. IV-RoM accuracy, repeatability and hypo-mobility cut-offs were determined. Minimal detectable changes (MDC) over 4 weeks were calculated
from controls. Patients and control IV-RoMs were compared at baseline as well as changes in patients over 4 weeks. Correlations between outcomes and the number of manipulations received and the agreement (Kappa) between palpated and QF-detected of hypo-mobile segments were calculated.
Results: QF had high accuracy (worst RMS error 0.5o) and repeatability (highest SEM 1.1o, lowest ICC 0.90) for
IV-RoM measurement. Hypo-mobility cut offs ranged from 0.8o to 3.5o. No outcome was significantly correlated with increased IV-RoM above MDC and there was no significant difference between the number of hypo-mobile segments in patients and controls at baseline or significant increases in IV-RoMs in patients. However, there was a modest and significant correlation between the number of manipulations received and the number of levels and directions whose IV-RoM increased beyond MDC (Rho=0.39, p=0.043). There was also no agreement between palpation and QF in identifying hypo-mobile segments (Kappa 0.04-0.06).
Conclusions: This study found no differences in cervical sagittal IV-RoM between patients with non-specific neck pain and matched controls. There was a modest dose-response relationship between the number of manipulations given and number of levels increasing IV-RoM - providing evidence that neck manipulation has a mechanical effect at segmental levels. However, patient-reported outcomes were not related to this
MiniBooNE and LSND data: non-standard neutrino interactions in a (3+1) scheme versus (3+2) oscillations
The recently observed event excess in MiniBooNE anti-neutrino data is in
agreement with the LSND evidence for electron anti-neutrino appearance. We
propose an explanation of these data in terms of a (3+1) scheme with a sterile
neutrino including non-standard neutrino interactions (NSI) at neutrino
production and detection. The interference between oscillations and NSI
provides a source for CP violation which we use to reconcile different results
from neutrino and anti-neutrino data. Our best fit results imply NSI at the
level of a few percent relative to the standard weak interaction, in agreement
with current bounds. We compare the quality of the NSI fit to the one obtained
within the (3+1) and (3+2) pure oscillation frameworks. We also briefly comment
on using NSI (in an effective two-flavour framework) to address a possible
difference in neutrino and anti-neutrino results from the MINOS experiment.Comment: 28 pages, 9 figures, discussion improved, new appendix added,
conclusions unchange
Visual fixation in the vegetative state: an observational case series PET study
BACKGROUND: Assessment of visual fixation is commonly used in the clinical examination of patients with disorders of consciousness. However, different international guidelines seem to disagree whether fixation is compatible with the diagnosis of the vegetative state (i.e., represents "automatic" subcortical processing) or is a sufficient sign of consciousness and higher order cortical processing. METHODS: We here studied cerebral metabolism in ten patients with chronic post-anoxic encephalopathy and 39 age-matched healthy controls. Five patients were in a vegetative state (without fixation) and five presented visual fixation but otherwise showed all criteria typical of the vegetative state. Patients were matched for age, etiology and time since insult and were followed by repeated Coma Recovery Scale-Revised (CRS-R) assessments for at least 1 year. Sustained visual fixation was considered as present when the eyes refixated a moving target for more than 2 seconds as defined by CRS-R criteria. RESULTS: Patients without fixation showed metabolic dysfunction in a widespread fronto-parietal cortical network (with only sparing of the brainstem and cerebellum) which was not different from the brain function seen in patients with visual fixation. Cortico-cortical functional connectivity with visual cortex showed no difference between both patient groups. Recovery rates did not differ between patients without or with fixation (none of the patients showed good outcome). CONCLUSIONS: Our findings suggest that sustained visual fixation in (non-traumatic) disorders of consciousness does not necessarily reflect consciousness and higher order cortical brain function
Nel positively regulates the genesis of retinal ganglion cells by promoting their differentiation and survival during development
Peer reviewedPublisher PD
- …