149 research outputs found
A 37-year-old woman presenting with impaired visual function during antituberculosis drug therapy: a case report
Abstract Introduction Combination antituberculosis drug therapy remains the mainstay of treating tuberculosis. Unfortunately, antituberculosis drugs produce side effects including (toxic) impaired visual function, which may be irreversible. We report a case of antituberculosis-drug-induced impaired visual function that was reversed following early detection and attention. Case presentation A 37-year-old Yoruba woman, weighing 48 kg, presented to our facility with impaired visual functions and mild sensory polyneuropathy in about the fourth month of antituberculosis treatment. Her therapy comprised ethambutol 825 mg, isoniazid 225 mg, rifampicin 450 mg, and pyrazinamide 1200 mg. Her visual acuity was 6/60 in her right eye and 1/60 in her left eye. She had sluggish pupils, red-green dyschromatopsia, hyperemic optic discs and central visual field defects. Her intraocular pressure was 14 mmHg. Her liver and kidney functions were essentially normal. Screening for human immunodeficiency virus was not reactive. Her impaired visual function improved following prompt diagnosis and attention, including the discontinuation of medication. Conclusions The ethambutol and isoniazid in antituberculosis medication are notorious for causing impaired visual function. The diagnosis of ocular toxicity from antituberculosis drugs should never be delayed, and should be possible with the patient's history and simple but basic eye examinations and tests. Tight weight-based antituberculosis therapy, routine peri-therapy visual function monitoring towards early detection of impaired function, and prompt attention will reduce avoidable ocular morbidity.</p
Lateral rectus metastasis from an occult systemic malignancy masquerading as abducens palsy: a case report
<p>Abstract</p> <p>Introduction</p> <p>Abduction deficit in the elderly is commonly caused by sixth cranial nerve palsy due to microvasculopathy. However, not all such cases are of neurogenic origin, as our case report shows.</p> <p>Case presentation</p> <p>We present the case of a 75-year-old woman who was generally unwell, developed acute diplopia and was found to have a right abduction deficit in a quiet eye with no gross orbital signs and symptoms. A computed tomography scan of the head and orbits revealed a metastatic mass in the right lateral rectus muscle. Systemic evaluation confirmed widespread thoracic and abdominal metastases from an occult systemic malignancy. Lateral rectus metastasis from an occult systemic malignancy was masquerading as abducens palsy.</p> <p>Conclusion</p> <p>Orbital metastasis involving extraocular muscles can present as isolated diplopia with minimal local signs and the absence of a history of systemic malignancy. A detailed history and systemic examination can identify suspicious cases, which should be investigated further. The clinician should avoid presuming that such an abduction deficit in the elderly is a benign neurogenic palsy.</p
Advanced Analysis Techniques for Intra-cardiac Flow Evaluation from 4D Flow MRI
Time-resolved 3D velocity-encoded MR imaging with velocity encoding in three directions (4D Flow) has emerged as a novel MR acquisition technique providing detailed information on flow in the cardiovascular system. In contrast to other clinically available imaging techniques such as echo-Doppler, 4D Flow MRI provides the 3D Flow velocity field within a volumetric region of interest over the cardiac cycle. This work reviews the most recent advances in the development and application of dedicated image analysis techniques for the assessment of intra-cardiac flow features from 4D Flow MRI.Novel image analysis techniques have been developed for extraction of relevant intra-cardiac flow features from 4D Flow MRI, which have been successfully applied in various patient cohorts and volunteer studies. Disturbed flow patterns have been linked with valvular abnormalities and ventricular dysfunction. Recent technical advances have resulted in reduced scan times and improvements in image quality, increasing the potential clinical applicability of 4D Flow MRI.4D Flow MRI provides unique capabilities for 3D visualization and quantification of intra-cardiac blood flow. Contemporary knowledge on 4D Flow MRI shows promise for further exploration of the potential use of the technique in research and clinical applications
Quantification and visualization of cardiovascular 4D velocity mapping accelerated with parallel imaging or k-t BLAST: head to head comparison and validation at 1.5 T and 3 T
<p>Abstract</p> <p>Background</p> <p>Three-dimensional time-resolved (4D) phase-contrast (PC) CMR can visualize and quantify cardiovascular flow but is hampered by long acquisition times. Acceleration with SENSE or k-t BLAST are two possibilities but results on validation are lacking, especially at 3 T. The aim of this study was therefore to validate quantitative in vivo cardiac 4D-acquisitions accelerated with parallel imaging and k-t BLAST at 1.5 T and 3 T with 2D-flow as the reference and to investigate if field strengths and type of acceleration have major effects on intracardiac flow visualization.</p> <p>Methods</p> <p>The local ethical committee approved the study. 13 healthy volunteers were scanned at both 1.5 T and 3 T in random order with 2D-flow of the aorta and main pulmonary artery and two 4D-flow sequences of the heart accelerated with SENSE and k-t BLAST respectively. 2D-image planes were reconstructed at the aortic and pulmonary outflow. Flow curves were calculated and peak flows and stroke volumes (SV) compared to the results from 2D-flow acquisitions. Intra-cardiac flow was visualized using particle tracing and image quality based on the flow patterns of the particles was graded using a four-point scale.</p> <p>Results</p> <p>Good accuracy of SV quantification was found using 3 T 4D-SENSE (r<sup>2 </sup>= 0.86, -0.7 ± 7.6%) and although a larger bias was found on 1.5 T (r<sup>2 </sup>= 0.71, -3.6 ± 14.8%), the difference was not significant (p = 0.46). Accuracy of 4D k-t BLAST for SV was lower (p < 0.01) on 1.5 T (r<sup>2 </sup>= 0.65, -15.6 ± 13.7%) compared to 3 T (r<sup>2 </sup>= 0.64, -4.6 ± 10.0%). Peak flow was lower with 4D-SENSE at both 3 T and 1.5 T compared to 2D-flow (p < 0.01) and even lower with 4D k-t BLAST at both scanners (p < 0.01). Intracardiac flow visualization did not differ between 1.5 T and 3 T (p = 0.09) or between 4D-SENSE or 4D k-t BLAST (p = 0.85).</p> <p>Conclusions</p> <p>The present study showed that quantitative 4D flow accelerated with SENSE has good accuracy at 3 T and compares favourably to 1.5 T. 4D flow accelerated with k-t BLAST underestimate flow velocities and thereby yield too high bias for intra-cardiac quantitative in vivo use at the present time. For intra-cardiac 4D-flow visualization, however, 1.5 T and 3 T as well as SENSE or k-t BLAST can be used with similar quality.</p
Clinical and surgical data of affected members of a classic CFEOM 1 family
BACKGROUND: Congenital fibiosis of the extraocular muscles (CFEOM1) refers to a group of congenital eye movement disorders that are characterized by non-progressive restrictive ophthalmoplegia. We present clinical and surgical data on affected members of a classic CFEOM1 family. METHODS: Ten members of a fifteen-member, three-generation Italian family affected by classic CFEOM participated in this study. Each affected family member underwent ophthalmologic (corrected visual acuity, pupillary function, anterior segment and fundus examination), orthoptic (cover test, cover-uncover test, prism alternate cover test), and preoperative examinations. Eight of the ten affected members had surgery and underwent postoperative examinations. Surgical procedures are listed. RESULTS: All affected members were born with varying degrees of bilateral ptosis and ophthalmoplegia with both eyes fixed in a hypotropic position (classic CFEOM). The affected members clinical data prior to surgery, surgery procedures and postoperative outcomes are presented. On 14 operated eyes to correct ptosis there was an improvement in 12 eyes. In addition, the head position improved in all patients. CONCLUSIONS: Surgery is effective at improving ptosis in the majority of patients with classic CFEOM. However, the surgical approach should be individualized to each patient, as inherited CFEOM exhibits variable expressivity and the clinical features may differ markedly between affected individuals, even within the same family
Recommended from our members
Fractal Dimension Analysis of Transient Visual Evoked Potentials: Optimisation and Applications
Purpose
The visual evoked potential (VEP) provides a time series signal response to an external visual stimulus at the location of the visual cortex. The major VEP signal components, peak latency and amplitude, may be affected by disease processes. Additionally, the VEP contains fine detailed and non-periodic structure, of presently unclear relevance to normal function, which may be quantified using the fractal dimension. The purpose of this study is to provide a systematic investigation of the key parameters in the measurement of the fractal dimension of VEPs, to develop an optimal analysis protocol for application.
Methods
VEP time series were mathematically transformed using delay time, Ď„, and embedding dimension, m, parameters. The fractal dimension of the transformed data was obtained from a scaling analysis based on straight line fits to the numbers of pairs of points with separation less than r versus log(r) in the transformed space. Optimal Ď„, m, and scaling analysis were obtained by comparing the consistency of results using different sampling frequencies. The optimised method was then piloted on samples of normal and abnormal VEPs.
Results
Consistent fractal dimension estimates were obtained using Ď„ = 4 ms, designating the fractal dimension = D2 of the time series based on embedding dimension m = 7 (for 3606 Hz and 5000 Hz), m = 6 (for 1803 Hz) and m = 5 (for 1000Hz), and estimating D2 for each embedding dimension as the steepest slope of the linear scaling region in the plot of log(C(r)) vs log(r) provided the scaling region occurred within the middle third of the plot. Piloting revealed that fractal dimensions were higher from the sampled abnormal than normal achromatic VEPs in adults (p = 0.02). Variances of fractal dimension were higher from the abnormal than normal chromatic VEPs in children (p = 0.01).
Conclusions
A useful analysis protocol to assess the fractal dimension of transformed VEPs has been developed
- …