180 research outputs found

    Anaconda: simulation-based synthesis of analog circuits via stochastic pattern search

    Full text link

    Development of High Power Broadband Gyro-TWAs Towards the Terahertz Range

    Get PDF
    In this paper gyrotron travelling wave amplifiers (gyro-TWAs) based on helically corrugated interaction regions will be presented. Their operating principle and the first experiment in X-band will be reviewed. The present experiment in W-band using a cusp electron beam source with the capability of a high pulse repetition frequency of 2 kHz will also be presented. The design and performances of the amplifiers for kilowatt output and broadband operation in the millimeter-wave and terahertz frequency ranges will also be presented

    Virtual Reality after Surgery—A Method to Decrease Pain After Surgery in Pediatric Patients

    Get PDF
    Background: Virtual Reality (VR) is used as an effective tool for distraction and as an adjunct for pain management. This study was conducted to compare VR to standard iPad use after surgery and examine its effect on pain score and opioid consumption. Methods: This was a randomized controlled study, with stratification by surgery type, age group (7-12yo, 13-18yo) and gender. Pain and anxiety were assessed with validated scales (STAI, FACES, VAS, FLACC) and outcomes were compared between each group. Results: 50 of the 106 enrolled patients used the VR device. After adjusting for age, gender, and STAI, patients had a decreased FLACC score while using the VR device compared to the iPad group (odds ratio 2.95, P =.021). The younger patients were found to have lower FLACC scores while using the VR device (odds ratio 1.15, p=0.044); this finding was most significant when patients used the VR device for 20-30 minutes (odds ratio 1.67, P =.0003). Additionally, after adjusting for treatment group, gender, and STAI, the younger patients had higher odds of withdrawal or exclusion from the study (odds ratio 1.18, P =.021). No significant difference in opioid consumption between the groups was found. Discussion: Virtual reality was well tolerated and more effective in decreasing pain during the immediate postoperative period than iPad use. Despite a slightly higher withdrawal rate, younger patients benefited more from the intervention

    First narrow-band search for continuous gravitational waves from known pulsars in advanced detector data

    Get PDF
    Spinning neutron stars asymmetric with respect to their rotation axis are potential sources of continuous gravitational waves for ground-based interferometric detectors. In the case of known pulsars a fully coherent search, based on matched filtering, which uses the position and rotational parameters obtained from electromagnetic observations, can be carried out. Matched filtering maximizes the signalto- noise (SNR) ratio, but a large sensitivity loss is expected in case of even a very small mismatch between the assumed and the true signal parameters. For this reason, narrow-band analysis methods have been developed, allowing a fully coherent search for gravitational waves from known pulsars over a fraction of a hertz and several spin-down values. In this paper we describe a narrow-band search of 11 pulsars using data from Advanced LIGO’s first observing run. Although we have found several initial outliers, further studies show no significant evidence for the presence of a gravitational wave signal. Finally, we have placed upper limits on the signal strain amplitude lower than the spin-down limit for 5 of the 11 targets over the bands searched; in the case of J1813-1749 the spin-down limit has been beaten for the first time. For an additional 3 targets, the median upper limit across the search bands is below the spin-down limit. This is the most sensitive narrow-band search for continuous gravitational waves carried out so far

    An Ultra-Low Background PMT for Liquid Xenon Detectors

    Get PDF
    Results are presented from radioactivity screening of two models of photomultiplier tubes designed for use in current and future liquid xenon experiments. The Hamamatsu 5.6 cm diameter R8778 PMT, used in the LUX dark matter experiment, has yielded a positive detection of four common radioactive isotopes: 238U, 232Th, 40K, and 60Co. Screening of LUX materials has rendered backgrounds from other detector materials subdominant to the R8778 contribution. A prototype Hamamatsu 7.6 cm diameter R11410 MOD PMT has also been screened, with benchmark isotope counts measured at <0.4 238U / <0.3 232Th / <8.3 40K / 2.0+-0.2 60Co mBq/PMT. This represents a large reduction, equal to a change of \times 1/24 238U / \times 1/9 232Th / \times 1/8 40K per PMT, between R8778 and R11410 MOD, concurrent with a doubling of the photocathode surface area (4.5 cm to 6.4 cm diameter). 60Co measurements are comparable between the PMTs, but can be significantly reduced in future R11410 MOD units through further material selection. Assuming PMT activity equal to the measured 90% upper limits, Monte Carlo estimates indicate that replacement of R8778 PMTs with R11410 MOD PMTs will change LUX PMT electron recoil background contributions by a factor of \times1/25 after further material selection for 60Co reduction, and nuclear recoil backgrounds by a factor of \times 1/36. The strong reduction in backgrounds below the measured R8778 levels makes the R11410 MOD a very competitive technology for use in large-scale liquid xenon detectors.Comment: v2 updated to include content after reviewer comments (Sep 2012

    LUXSim: A Component-Centric Approach to Low-Background Simulations

    Get PDF
    Geant4 has been used throughout the nuclear and high-energy physics community to simulate energy depositions in various detectors and materials. These simulations have mostly been run with a source beam outside the detector. In the case of low-background physics, however, a primary concern is the effect on the detector from radioactivity inherent in the detector parts themselves. From this standpoint, there is no single source or beam, but rather a collection of sources with potentially complicated spatial extent. LUXSim is a simulation framework used by the LUX collaboration that takes a component-centric approach to event generation and recording. A new set of classes allows for multiple radioactive sources to be set within any number of components at run time, with the entire collection of sources handled within a single simulation run. Various levels of information can also be recorded from the individual components, with these record levels also being set at runtime. This flexibility in both source generation and information recording is possible without the need to recompile, reducing the complexity of code management and the proliferation of versions. Within the code itself, casting geometry objects within this new set of classes rather than as the default Geant4 classes automatically extends this flexibility to every individual component. No additional work is required on the part of the developer, reducing development time and increasing confidence in the results. We describe the guiding principles behind LUXSim, detail some of its unique classes and methods, and give examples of usage. * Corresponding author, [email protected]: 45 pages, 15 figure

    Variety of Methodological Approach in Economics

    Get PDF
    It has been argued by some that the distinction between orthodox economics and heterodox economics does not fit the growing variety in economic theory, unified by a common methodological approach. On the other hand, it remains a central characteristic of heterodox economics that it does not share this methodological approach, but rather represents a range of alternative methodological approaches. The paper explores the evidence, and arguments, for variety in economics at different levels, and a range of issues which arise. This requires in turn a discussion of the meaning of variety in economics at the different levels of reality, methodology, method and theory. It is concluded that there is scope for more, rather than less, variety in economic methodologies, as well as within methodologies. Further, if variety is not to take the form of “anything goes”, then critical discussion by economists of different approaches to economics, and of variety itself, is required

    All-sky search for long-duration gravitational wave transients with initial LIGO

    Get PDF
    We present the results of a search for long-duration gravitational wave transients in two sets of data collected by the LIGO Hanford and LIGO Livingston detectors between November 5, 2005 and September 30, 2007, and July 7, 2009 and October 20, 2010, with a total observational time of 283.0 days and 132.9 days, respectively. The search targets gravitational wave transients of duration 10-500 s in a frequency band of 40-1000 Hz, with minimal assumptions about the signal waveform, polarization, source direction, or time of occurrence. All candidate triggers were consistent with the expected background; as a result we set 90% confidence upper limits on the rate of long-duration gravitational wave transients for different types of gravitational wave signals. For signals from black hole accretion disk instabilities, we set upper limits on the source rate density between 3.4×10-5 and 9.4×10-4 Mpc-3 yr-1 at 90% confidence. These are the first results from an all-sky search for unmodeled long-duration transient gravitational waves. © 2016 American Physical Society

    All-sky search for long-duration gravitational wave transients with initial LIGO

    Get PDF
    We present the results of a search for long-duration gravitational wave transients in two sets of data collected by the LIGO Hanford and LIGO Livingston detectors between November 5, 2005 and September 30, 2007, and July 7, 2009 and October 20, 2010, with a total observational time of 283.0 days and 132.9 days, respectively. The search targets gravitational wave transients of duration 10-500 s in a frequency band of 40-1000 Hz, with minimal assumptions about the signal waveform, polarization, source direction, or time of occurrence. All candidate triggers were consistent with the expected background; as a result we set 90% confidence upper limits on the rate of long-duration gravitational wave transients for different types of gravitational wave signals. For signals from black hole accretion disk instabilities, we set upper limits on the source rate density between 3.4×10-5 and 9.4×10-4 Mpc-3 yr-1 at 90% confidence. These are the first results from an all-sky search for unmodeled long-duration transient gravitational waves. © 2016 American Physical Society

    Search for Tensor, Vector, and Scalar Polarizations in the Stochastic Gravitational-Wave Background

    Get PDF
    The detection of gravitational waves with Advanced LIGO and Advanced Virgo has enabled novel tests of general relativity, including direct study of the polarization of gravitational waves. While general relativity allows for only two tensor gravitational-wave polarizations, general metric theories can additionally predict two vector and two scalar polarizations. The polarization of gravitational waves is encoded in the spectral shape of the stochastic gravitational-wave background, formed by the superposition of cosmological and individually unresolved astrophysical sources. Using data recorded by Advanced LIGO during its first observing run, we search for a stochastic background of generically polarized gravitational waves. We find no evidence for a background of any polarization, and place the first direct bounds on the contributions of vector and scalar polarizations to the stochastic background. Under log-uniform priors for the energy in each polarization, we limit the energy densities of tensor, vector, and scalar modes at 95% credibility to Ω0T<5.58×10-8, Ω0V<6.35×10-8, and Ω0S<1.08×10-7 at a reference frequency f0=25 Hz. © 2018 American Physical Society
    • 

    corecore