475 research outputs found
Hydrogen Generation by Treatment of Aluminium Metal with Aqueous Solutions: Procedures and Uses
Effect of obstacle position in the flow of sheep through a narrow door
In a recent work Phys. Rev. E 91, 022808 (2015)PLEEE81539-375510.1103/PhysRevE.91.022808] it was reported that placing an obstacle in front of a gate has a beneficial effect in the flow of sheep through it. Here, we extend such results by implementing three different obstacle positions. We have observed that the flow is improved in two cases, while it worsens in the other one; the last instance happens when the obstacle is too close to the door. In this situation, the outcomes suggest that clogging develops between the doorjamb and the obstacle, contrary to the cases when the obstacle is farther, in which case clogging always occurs at the very door. The effectiveness of the obstacle (a strategy put forward to alleviate clogging in emergency exits) is therefore quite sensitive to its location. In addition, the study of the temporal evolution of the flow rate as the test develops makes evident a steady behavior during the entire duration of the entrance. This result is at odds with recent findings in human evacuation tests where the flow rate varies over time, therefore challenging the fairness of straightforward comparisons between pedestrian behavior and animal experimental observations
Matrix architecture plays a pivotal role in 3D osteoblast migration: The effect of interstitial fluid flow
Osteoblast migration is a crucial process in bone regeneration, which is strongly regulated by interstitial fluid flow. However, the exact role that such flow exerts on osteoblast migration is still unclear. To deepen the understanding of this phenomenon, we cultured human osteoblasts on 3D microfluidic devices under different fluid flow regimes. Our results show that a slow fluid flow rate by itself is not able to alter the 3D migratory patterns of osteoblasts in collagen-based gels but that at higher fluid flow rates (increased flow velocity) may indirectly influence cell movement by altering the collagen microstructure. In fact, we observed that high fluid flow rates (1 µl/min) are able to alter the collagen matrix architecture and to indirectly modulate the migration pattern. However, when these collagen scaffolds were crosslinked with a chemical crosslinker, specifically, transglutaminase II, we did not find significant alterations in the scaffold architecture or in osteoblast movement. Therefore, our data suggest that high interstitial fluid flow rates can regulate osteoblast migration by means of modifying the orientation of collagen fibers. Together, these results highlight the crucial role of the matrix architecture in 3D osteoblast migration. In addition, we show that interstitial fluid flow in conjunction with the matrix architecture regulates the osteoblast morphology in 3D
Influencia del tratamiento químico con cloroformo/metanol en el comportamiento elástico del pericardio de ternera utilizado en la construcción de bioprótesis cardiacas
Se estudia el comportamiento mecánico del pericardio de ternera utilizado en la construcción de
bioprótesis cardiacas cuando se trata químicamente cloroformo/metanol (CM) comparándolo con
tratamiento estándar con glutaraldehído.(G). Se ensayan a tracción hasta rotura 40 probetas, veinte
con cada tratamiento y de estas el 50% suturadas en su parte central con seda 4/0.La perdida de
resistencia media a la rotura de las probetas suturadas fue de alrededor de 6 MPa sin encontrar
diferencias entre el tipo de tratamiento utilizado. No obstante en el análisis de las curvas promedio
estrés/deformación para valores de estrés a tracción inferiores a 2.5 MPa, apenas encontramos
diferencias entre las series suturadas y no suturadas tratadas con cloroformo/metanol anulando
parcialmente el efecto deletéreo de la sutura en ese rango de estrés que incluye el estrés estimado de
trabajo, de 0.25MPa.El tratamiento con cloroformo/metanol podría, además de retrasar los procesos
de calcificación del pericardio, mejorar el comportamiento elástico de las probetas suturadas
disminuyendo la interacción con la sutura. Ensayos de fatiga real con este tratamiento químico
deberán ser realizados para verificar esta hipótesis.Peer Reviewe
Fijación de materiales biológicos mediante suturas y adhesivos biológicos
Las suturas son los elementos usados para fijar implantes o velos valvulares de las bioprótesis
cardiacas. Tienen gran resistencia, su escasa elasticidad genera tensiones internas en los elementos
que fijan. Se han comenzado a utilizar con fines médicos en la cirugía adherentes biológicos
como elementos de fijación aunque no hay experiencia en bioprótesis.
El objetivo de este trabajo era conocer si las muestras suturadas y pegadas eran capaces de
proporcionar resistencia y elasticidad suficiente como para aportar un beneficio a la sutura, en la
fijación de implantes o en la construcción de bioprótesis cardiacas. Para ello, hemos diseñado un
ensayo de resistencia a tracción de 60 muestras de pericardio de ternera, material que se utiliza
para fabricar velos valvulares de bioprótesis, comparando el comportamiento mecánico de 24
muestras suturadas con sutura continua borde a borde, prolene 5/0, a 45º y 90º del eje principal de
la carga y otras 24 muestras similares, en las que el ojal del hilo de sutura (o parte del tejido que
atraviesa la aguja de sutura) había sido reforzado con un adhesivo de fibrina. Como grupo de
control se emplearon doce muestras sin sutura ni adhesivo.
Los resultados obtenidos confirman la pérdida de resistencia al esfuerzo de tracción de las
muestras suturadas, borde a borde, independientemente de la dirección de la sutura en relación
con el eje principal de la carga. Esta forma de sutura no debe ser utilizada.
La pérdida de resistencia se manifiesta tras pequeñas deformaciones de las muestras de pericardio.
Para un 15% de deformación el estrés medio necesario para el grupo de control fue de 3.15 MPa
frente a 0.92 MPa y 1.98 MPa, valores extremos de las series suturadas (p<0.01).
Por otra parte, el uso de adherentes de fibrina no mejoró ni la resistencia ni la elasticidad de las
muestras, aunque homogenizó el comportamiento mecánico de aquellas muestras suturadas que
reforzaron con adherente de fibrina los ojales de paso de los hilos de sutura.Peer Reviewe
ILLUMINATING THE DARKEST GAMMA-RAY BURSTS WITH RADIO OBSERVATIONS
We present X-ray, optical, near-infrared (IR), and radio observations of gamma-ray bursts (GRBs) 110709B and 111215A, as well as optical and near-IR observations of their host galaxies. The combination of X-ray detections and deep optical/near-IR limits establish both bursts as "dark." Sub-arcsecond positions enabled by radio detections lead to robust host galaxy associations, with optical detections that indicate z ≾ 4 (110709B) and z ≈ 1.8-2.9 (111215A). We therefore conclude that both bursts are dark due to substantial rest-frame extinction. Using the radio and X-ray data for each burst we find that GRB 110709B requires A_V^(host) ≳ 5.3 mag and GRB 111215A requires A_V^(host) ≳ 8.5 mag (assuming z = 2). These are among the largest extinction values inferred for dark bursts to date. The two bursts also exhibit large neutral hydrogen column densities of N H, int ≳ 10^(22) cm^(–2) (z = 2) as inferred from their X-ray spectra, in agreement with the trend for dark GRBs. Moreover, the inferred values are in agreement with the Galactic A_V -N_H relation, unlike the bulk of the GRB population. Finally, we find that for both bursts the afterglow emission is best explained by a collimated outflow with a total beaming-corrected energy of E_γ + E_K ≈ (7-9) × 10^(51) erg (z = 2) expanding into a wind medium with a high density, Ṁ ≈ (6-20) x 10^(-5) M_☉ yr^(–1) (n ≈ 100-350 cm^(–3) at ≈ 10^(17) cm). While the energy release is typical of long GRBs, the inferred density may be indicative of larger mass-loss rates for GRB progenitors in dusty (and hence metal rich) environments. This study establishes the critical role of radio observations in demonstrating the origin and properties of dark GRBs. Observations with the JVLA and ALMA will provide a sample with sub-arcsecond positions and robust host associations that will help to shed light on obscured star formation and the role of metallicity in GRB progenitors
Pretensado y comportamiento mecánico del pericardio de ternera utilizado en la construcción de bioprótesis cardíacas
Este trabajo analiza las propiedades mecánicas de un tejido biológico, pericardio de bovino
empleado como biomaterial en la fabricación de bioprótesis cardíacas. Para ello se sometió
pericardio de ternera a un estrés de tracción, uniaxial, en escalones de carga, con retirada de dicha
carga tras cada escalón. Los escalones de carga fueron de aproximadamente 2,3 y 8 MPa sucesivamente,
continuándose finalmente el ensayo hasta la rotura. Se ensayaron 32 muestras, 16 tratadas
con glutaraldehído como grupo de control y 16 tratadas con cloroformo/metanol. La resistencia
media a rotura estuvo entre 19.14 MPa y 32.60 MPa sin encontrar diferencias estadísticamente
significativas en la comparación de las series ensayadas. Se estudio también el estrés remanente
tras cada escalón de carga, siendo este constante en su valor para cada ensayo. Para un valor
medio de estrés inicial de 2.14 MPa, el estrés remanente medio fue de 0.36 MPa (16.82 % del estrés
inicial) muy similar al estrés máximo de trabajo descrito para un velo valvular. La aplicación de un
estrés progresivo produce una disminución de la deformación con pérdida de la elasticidad ,pero
un comportamiento mas homogéneo del pericardio. Este hallazgo no se afectó, por la región de
pericardio de donde se obtuvo la muestra o por tratamiento químico recibido. Estos ensayos permiten,
mediante una recta de regresión Xi=f(Ymax.),conocer la deformación (Xi) que puede sufrir el
pericardio de ternera, tras un estrés de pretensado previo (Ymax.), cuando posteriormente se le
somete a un estrés.Peer Reviewe
Does student satisfaction depend on the actual quality of the faculty or on the perception of the student? Comparative analysis between public and private faculties
El objetivo de este estudio es conocer la satisfacción estudiantil en relación a las universidades públicas y privadas. Es un estudio correlacional, realizado en la Universidad de Granada en la escuela universitaria de magisterio La Inmaculada y en la de facultad de ciencias de la educación. Participaron 111 alumnos entre ambas facultades que completaron un cuestionario sobre satisfacción estudiantil. Los principales resultados exponen que a pesar de no obtener diferencias significativas en la satisfacción global, sí lo hacen en distintos aspectos, obteniendo mayor satisfacción los estudiantes de la Facultad privada, en competencias profesionales y servicio administrativo, en comparación con los de la pública que obtienen mayores puntuaciones en satisfacción con el ambiente en la facultad y la biblioteca.The aim of this study is to determine student satisfaction in relation to public and private universities. The study is correlational, and was carried out in Granada, at the University School of Education of La Inmaculada and at the Faculty of Education. 111 students from both faculties completed a questionnaire about student satisfaction. The main results of this study show that despite there not being significant differences in the overall mean, there were differences in some aspects as the private university students were more satisfied with respect to professional skills, and admininistrative service than the public university students who obtained higher scores in satisfaction with the atmosphere of the faculty and of the library.Psicología Socia
Time-related efficacy of liver cell isografts in fulminant hepatic failure
We and others have reported that dispersed liver cells transplanted into the
spleen parenchyma of syngeneic rats remained functional and viable for a long
time. This report describes our results with hepatocellular transplantation as a
therapeutic method in a model of fulminant hepatic failure (FHF) in the rat. 60
male Sprague-Dawley rats weighing 200-250 g were used. The FHF was reached
through an Eck's fistula with 2/3 hepatectomy at the same time. This model
produced lethal hepatic failure in a highly reproducible manner. Liver cells were
isolated by the collagenase method. 40 X 10(6) hepatocytes suspended in Hanks'
balanced salt solution were transplanted into the spleen parenchyma 24 hr before
(group 1), at the same time as (group 2), and 24 hr after (group 3) FHF was
achieved. Additional sham-operated animals (groups 4 and 5) and a control group
(group 6) were used. The hepatocellular transplantation markedly increased the
survival of the animals with induced FHF to 80% (group 1) and 60% (group 2)--but
not in group 3 (20%),--compared with 10% in the control group. This study shows
that dispersed liver cells transplanted into the spleen can provide sufficient
support to allow animals with lethal hepatic failure to survive and recover.
Nevertheless the efficacy of transplantation is a time-related phenomenon with
the FHF induction
Resistencia mecánica del pericardio de ternera utilizado en la construcción de bioprótesis cardíacas tratadas con dodecil sulfato sódico
Para mitigar la calcificación de las bioprótesis cardiacas fabricadas con pericardio de ternera
o válvulas porcinas se aplican tratamientos químicos posteriores al entrecruzamiento con
glutaraldehído.
Uno de los tratamientos ensayados ha sido el surfactante dodecil sulfato sódico(DSS). Este
detergente inhibe, en modelos experimentales,en pequeños animales, la calcificación del pericardio
de ternera utilizado en la construcción de bioprótesis cardiacas.
Estudiamos el comportamiento mecánico del pericardio tratado, con este detergente, comparándolo
con un tratamiento control con glutaraldehído (GA) 0.625% durante 24 horas.
Se ensayaron al esfuerzo de tracción muestras pareadas, es decir, cortadas de forma contigua y
en la misma dirección del corte, tratadas respectivamente con glutaraldehído (grupo de control) y
con dodecil sulfato sódico (DSS). El tejido tratado con DSS fue a su vez incubado con dos tiempos
diferentes 2 o 24 horas respectivamente y posteriormente tratados con glutaraldehído (GA). En las
muestras tratadas dos horas con DSS,se observó un estrés de rotura similar al de las parejas que
recibieron el tratamiento de control.Los valores estuvieron comprendidos entre 8.42 y 15.81 MPa.
Las muestras tratadas con DSS, 24 horas perdieron su resistencia mecánica. El estrés de rotura
medio osciló entre 1.77 y 1.95 MPa, existiendo diferencias estadísticamente significativas (p<0.001),
cuando se las comparaba con el grupo control tratado con GA.
Por otra parte cuando se analizó la elasticidad, las series tratadas con DSS y dos horas de
incubación presentaron en la región elástica, módulos de elasticidad menores, cuando se comparan
con valores similares de las series de control, dejando patente la mayor elasticidad del
biomaterial tratado con DSS.
Desde el punto de vista de investigación aplicada la buena correlación obtenida, cuando se
comparan mediante mínimos cuadrados las muestras pareadas, permite predecir el comportamiento
mecánico de una muestra, conocido el comportamiento de la muestra adyacente o pareja.Peer Reviewe
- …