1,484 research outputs found

    Absolute velocity measurements in sunspot umbrae

    Full text link
    In sunspot umbrae, convection is largely suppressed by the strong magnetic field. Previous measurements reported on negligible convective flows in umbral cores. Based on this, numerous studies have taken the umbra as zero reference to calculate Doppler velocities of the ambient active region. To clarify the amount of convective motion in the darkest part of umbrae, we directly measured Doppler velocities with an unprecedented accuracy and precision. We performed spectroscopic observations of sunspot umbrae with the Laser Absolute Reference Spectrograph (LARS) at the German Vacuum Tower Telescope. A laser frequency comb enabled the calibration of the high-resolution spectrograph and absolute wavelength positions. A thorough spectral calibration, including the measurement of the reference wavelength, yielded Doppler shifts of the spectral line Ti i 5713.9 {\AA} with an uncertainty of around 5 m s-1. The measured Doppler shifts are a composition of umbral convection and magneto-acoustic waves. For the analysis of convective shifts, we temporally average each sequence to reduce the superimposed wave signal. Compared to convective blueshifts of up to -350 m s-1 in the quiet Sun, sunspot umbrae yield a strongly reduced convective blueshifts around -30 m s-1. {W}e find that the velocity in a sunspot umbra correlates significantly with the magnetic field strength, but also with the umbral temperature defining the depth of the titanium line. The vertical upward motion decreases with increasing field strength. Extrapolating the linear approximation to zero magnetic field reproduces the measured quiet Sun blueshift. Simply taking the sunspot umbra as a zero velocity reference for the calculation of photospheric Dopplergrams can imply a systematic velocity error.Comment: 10 pages, 7 figures, 2 tables, Appendix with 5 figure

    Critical conditions for the wetting of soils

    Get PDF
    The wettability of soil is of great importance for plants and soil biota and in determining whether flooding and soil erosion will occur. The analysis used in common measurements of soil hydrophobicity makes the assumption that water always enters soils if the average contact angle between the soil and water is 90 degrees or lower; these tests have been used for decades. The authors show theoretically and experimentally that water cannot enter many soils unless the contact angle is considerably lower than this, down to approximately 50 degrees. This difference generates serious errors in determining and modeling soil wetting behavior

    Particulate emissions from large North American wildfires estimated using a new top-down method

    Get PDF
    Particulate matter emissions from wildfires affect climate, weather and air quality. However, existing global and regional aerosol emission estimates differ by a factor of up to 4 between different methods. Using a novel approach, we estimate daily total particulate matter (TPM) emissions from large wildfires in North American boreal and temperate regions. Moderate Resolution Imaging Spectroradiometer (MODIS) fire location and aerosol optical thickness (AOT) data sets are coupled with HYSPLIT (Hybrid Single-Particle Lagrangian Integrated Trajectory) atmospheric dispersion simulations, attributing identified smoke plumes to sources. Unlike previous approaches, the method (i) combines information from both satellite and AERONET (AErosol RObotic NETwork) observations to take into account aerosol water uptake and plume specific mass extinction efficiency when converting smoke AOT to TPM, and (ii) does not depend on instantaneous emission rates observed during individual satellite overpasses, which do not sample night-time emissions. The method also allows multiple independent estimates for the same emission period from imagery taken on consecutive days. <br><br> Repeated fire-emitted AOT estimates for the same emission period over 2 to 3 days of plume evolution show increases in plume optical thickness by approximately 10 % for boreal events and by 40 % for temperate emissions. Inferred median water volume fractions for aged boreal and temperate smoke observations are 0.15 and 0.47 respectively, indicating that the increased AOT is partly explained by aerosol water uptake. TPM emission estimates for boreal events, which predominantly burn during daytime, agree closely with bottom-up Global Fire Emission Database (GFEDv4) and Global Fire Assimilation System (GFASv1.0) inventories, but are lower by approximately 30 % compared to Quick Fire Emission Dataset (QFEDv2) PM<sub>2. 5</sub>, and are higher by approximately a factor of 2 compared to Fire Energetics and Emissions Research (FEERv1) TPM estimates. The discrepancies are larger for temperate fires, which are characterized by lower median fire radiative power values and more significant night-time combustion. The TPM estimates for this study for the biome are lower than QFED PM<sub>2. 5</sub> by 35 %, and are larger by factors of 2.4, 3.2 and 4 compared with FEER, GFED and GFAS inventories respectively. A large underestimation of TPM emission by bottom-up GFED and GFAS indicates low biases in emission factors or consumed biomass estimates for temperate fires

    Rigorous treatment of electrostatics for spatially varying dielectrics based on energy minimization

    Full text link
    A novel energy minimization formulation of electrostatics that allows computation of the electrostatic energy and forces to any desired accuracy in a system with arbitrary dielectric properties is presented. An integral equation for the scalar charge density is derived from an energy functional of the polarization vector field. This energy functional represents the true energy of the system even in non-equilibrium states. Arbitrary accuracy is achieved by solving the integral equation for the charge density via a series expansion in terms of the equation's kernel, which depends only on the geometry of the dielectrics. The streamlined formalism operates with volume charge distributions only, not resorting to introducing surface charges by hand. Therefore, it can be applied to any spatial variation of the dielectric susceptibility, which is of particular importance in applications to biomolecular systems. The simplicity of application of the formalism to real problems is shown with analytical and numerical examples.Comment: 27 pages, 5 figure

    Comb-calibrated solar spectroscopy through a multiplexed single-mode fiber channel

    Get PDF
    We investigate a new scheme for astronomical spectrograph calibration using the laser frequency comb at the Solar Vacuum Tower Telescope on Tenerife. Our concept is based upon a single-mode fiber channel, that simultaneously feeds the spectrograph with comb light and sunlight. This yields nearly perfect spatial mode matching between the two sources. In combination with the absolute calibration provided by the frequency comb, this method enables extremely robust and accurate spectroscopic measurements. The performance of this scheme is compared to a sequence of alternating comb and sunlight, and to absorption lines from Earth's atmosphere. We also show how the method can be used for radial-velocity detection by measuring the well-explored 5-minute oscillations averaged over the full solar disk. Our method is currently restricted to solar spectroscopy, but with further evolving fiber-injection techniques it could become an option even for faint astronomical targets.Comment: 21 pages, 11 figures. A video abstract for this paper is available on youtube. For watching the video, please follow https://www.youtube.com/watch?v=oshdZgrt89I . The video abstract is also available for streaming and download on the related article website of New Journal of Physic

    First-Hitting Times Under Additive Drift

    Full text link
    For the last ten years, almost every theoretical result concerning the expected run time of a randomized search heuristic used drift theory, making it the arguably most important tool in this domain. Its success is due to its ease of use and its powerful result: drift theory allows the user to derive bounds on the expected first-hitting time of a random process by bounding expected local changes of the process -- the drift. This is usually far easier than bounding the expected first-hitting time directly. Due to the widespread use of drift theory, it is of utmost importance to have the best drift theorems possible. We improve the fundamental additive, multiplicative, and variable drift theorems by stating them in a form as general as possible and providing examples of why the restrictions we keep are still necessary. Our additive drift theorem for upper bounds only requires the process to be nonnegative, that is, we remove unnecessary restrictions like a finite, discrete, or bounded search space. As corollaries, the same is true for our upper bounds in the case of variable and multiplicative drift

    The Relevance of Pyrogenic Carbon for Carbon Budgets From Fires: Insights From the FIREX Experiment

    Get PDF
    Vegetation fires play an important role in global and regional carbon cycles. Due to climate warming and land use shifts, fire patterns are changing and fire impacts increasing in many of the world's regions. Reducing uncertainties in carbon budgeting calculations from fires is therefore fundamental to advance our current understanding and forecasting capabilities. Here we study 20 chamber burns from the FIREX FireLab experiment, which burnt a representative set of North American wildland fuels, to assess the following: (i) differences in carbon emission estimations between the commonly used “consumed biomass” approach and the “burnt carbon” approach; (ii) pyrogenic carbon (PyC) production rates; and (iii) thermal and chemical recalcitrance of the PyC produced, as proxies of its biogeochemical stability. We find that the “consumed biomass” approach leads to overestimation of carbon emissions by 2–27% (most values between 2% and 10%). This accounting error arises largely from not considering PyC production and, even if relatively small, can therefore have important implications for medium‐ and long‐term carbon budgeting. A large fraction (34–100%) of this PyC was contained in the charred fine residue, a postfire material frequently overlooked in fire carbon research. However, the most recalcitrant PyC was in the form of woody charcoal, with estimated half‐lives for most samples exceeding 1,000 years. Combustion efficiency was relatively high in these laboratory burns compared to actual wildland fire conditions, likely leading to lower PyC production rates. We therefore argue that the PyC production values obtained here, and associated overestimation of carbon emissions, should be taken as low‐end estimates for wildland fire conditions

    Duplex ultrasound imaging alone is sufficient for midterm endovascular aneurysm repair surveillance: A cost analysis study and prospective comparison with computed tomography scan

    Get PDF
    ObjectiveEarly in our experience with endovascular aortic aneurysm repair (EVAR) we performed both serial computed tomography scans and duplex ultrasound (DU) imaging in our post-EVAR surveillance regimen. Later we conducted a prospective study with DU imaging as the sole surveillance study and determined cost savings and outcome using this strategy.MethodsFrom September 21, 1998, to May 30, 2008, 250 patients underwent EVAR at our hospital. Before July 1, 2004, EVAR patients underwent CT and DU imaging performed every 6 months during the first year and then annually if no problems were identified (group 1). We compared aneurysm sac size, presence of endoleak, and graft patency between the two scanning modalities. After July 1, 2004, patients underwent surveillance using DU imaging as the sole surveillance study unless a problem was detected (group 2). CT and DU imaging charges for each regimen were compared using our 2008 health system pricing and Medicare reimbursements. All DU examinations were performed in our accredited noninvasive vascular laboratory by experienced technologists. Statistical analysis was performed using Pearson correlation coefficient.ResultsDU and CT scans were equivalent in determining aneurysm sac diameter after EVAR (P < .001). DU and CT were each as likely to falsely suggest an endoleak when none existed and were as likely to miss an endoleak. Using DU imaging alone would have reduced cost of EVAR surveillance by 29% (534,356)ingroup1.Costsavingsof534,356) in group 1. Cost savings of 1595 per patient per year were realized in group 2 by eliminating CT scan surveillance. None of the group 2 patients sustained an adverse event such as rupture, graft migration, or limb occlusion as a result of having DU imaging performed as the sole follow-up modality.ConclusionSurveillance of EVAR patients can be performed accurately, safely, and cost-effectively with DU as the sole imaging study
    • 

    corecore