186 research outputs found

    The use of pocket-size imaging devices: a position statement of the European Association of Echocardiography.

    Full text link
    Pocket-size imaging devices are a completely new type of echo machines which have recently reached the market. They are very cheap, smartphone-size hand-held echo machines with limited technical capabilities. The aim of this European Association of Echocardiography (EAE) position paper is to provide recommendations on the use of pocket-size imaging devices in the clinical arena by profiling the educational needs of potential users other than cardiologists experts in echo. EAE recommendations about pocket-size imaging devices can be summarized in: (1) pocket-size imaging devices do not provide a complete diagnostic echocardiographic examination. The range of indications for their use is therefore limited. (2) Imaging assessment with pocket-size imaging devices should be reported as part of the physical examination of the patient. Image data should be stored according to the applicable national rules for technical examinations. (3) With the exception of cardiologists who are certified for transthoracic echocardiography according to national legislation, specific training and certification is recommended for all users. The certification should be limited to the clinical questions that can potentially be answered by pocket-size devices. (4) The patient has to be informed that an examination with the current generation of pocket-size imaging devices does not replace a complete echocardiogram.Peer reviewe

    Twenty-first-century compatible co2 emissions and airborne fraction simulated by cmip5 earth system models under four representative concentration pathways

    Get PDF
    PublishedJournal ArticleThe carbon cycle is a crucial Earth system component affecting climate and atmospheric composition. The response of natural carbon uptake to CO2 and climate change will determine anthropogenic emissions compatible with a target CO2 pathway. For phase 5 of the Coupled Model Intercomparison Project (CMIP5), four future representative concentration pathways (RCPs) have been generated by integrated assessment models (IAMs) and used as scenarios by state-of-the-art climate models, enabling quantification of compatible carbon emissions for the four scenarios by complex, process-based models. Here, the authors present results from 15 such Earth system GCMs for future changes in land and ocean carbon storage and the implications for anthropogenic emissions. The results are consistent with the underlying scenarios but show substantial model spread. Uncertainty in land carbon uptake due to differences among models is comparable with the spread across scenarios. Model estimates of historical fossil-fuel emissions agree well with reconstructions, and future projections for representative concentration pathway 2.6 (RCP2.6) and RCP4.5 are consistent with the IAMs. For high-end scenarios (RCP6.0 and RCP8.5), GCMs simulate smaller compatible emissions than the IAMs, indicating a larger climate-carbon cycle feedback in the GCMs in these scenarios. For the RCP2.6 mitigation scenario, an average reduction of 50% in emissions by 2050 from 1990 levels is required but with very large model spread (14%-96%). The models also disagree on both the requirement for sustained negative emissions to achieve the RCP2.6 CO2 concentration and the success of this scenario to restrict global warming below 28C. All models agree that the future airborne fraction depends strongly on the emissions profile with higher airborne fraction for higher emissions scenarios. ©2013 American Meteorological Society.MOHC authors were supported by the JointDECC/Defra MetOffice Hadley Centre Climate Programme (GA01101), and work to performHadGEM2- ES and MPI-ESM CMIP5 simulations was supported by the EU-FP7 COMBINE project (Grant 226520). JS was supported by the EU-FP7 CARBOCHANGE project (Grant 284679). We acknowledge the World Climate Research Programme’s Working Group on Coupled Modelling, which is responsible for CMIP, and we thank the climate modeling groups (listed in Table 1 of this paper) for producing and making available their model output. For CMIP, the U.S. Department of Energy’s Program for Climate Model Diagnosis and Intercomparison provides coordinating support and led development of software infrastructure in partnership with the Global Organization for Earth System Science Portals. JT and CR were supported by the Research Council of Norway through the EarthClim (207711/E10) project

    Upon the Relation between Fats and Oils with Sulphur as Fungicide (V)

    Get PDF
    This study was done to ascertain whether three-dimensional echocardiography can facilitate the diagnosis of mitral valve abnormalities. The value of the additional information provided by three-dimensional echocardiography compared with two-dimensional multiplane transesophageal echocardiography for evaluation of the mitral valve apparatus has not been assessed. Thirty patients with a variety of mitral valve pathologies (stenosis in 8, insufficiency in 12, prostheses in 10) and 20 subjects with a normal mitral valve were studied. Images were acquired using the rotational technique (ever 2 degrees), with electrocardiographic and respiratory gating. From the three-dimensional data sets, cut planes were selected and presented in both two-dimensional format (anyplane echocardiography) and volume-rendered dynamic display. The data were compared with the original multiplane two-dimensional images. Different features of the mitral valve apparatus were defined and graded by three observers for clarity of visualization and confidence of interpretation as 1) inadequate, 2) sufficient, or 3) excellent. All the techniques provided good visualization of the mitral valve (mean global scores +/- SD for multiplane, anyplane and volume-rendered echocardiography were 2.22 +/- 0.34, 2.24 +/- 0.26 and 2.30 +/- 0.25, respectively). With volume-rendered echocardiography, the mitral valve apparatus was scored higher in pathologic than in normal conditions (2.38 +/- 0.24 vs. 2.16 +/- 0.21, p < 0.002). The spatial relationships between the mitral valve and other structures, leaflet mobility, commissures and orifice were scored higher by volume-rendered echocardiography. Prostheses were evaluated equally well by the three methods. Multiplane and anyplane echocardiography were superior for the evaluation of leaflet thickness, subvalvular apparatus and annulus. Transesophageal three-dimensional echocardiography facilitates imaging of some features of the mitral valve apparatus and provides additional information for comprehensive assessment of mitral valve abnormalitie

    Necrostatin-1 Analogues: Critical Issues on the Specificity, Activity and In Vivo Use in Experimental Disease Models

    Get PDF
    Necrostatin-1 (Nec-1) is widely used in disease models to examine the contribution of receptor-interacting protein kinase (RIPK) 1 in cell death and inflammation. We studied three Nec-1 analogs: Nec-1, the active inhibitor of RIPK1, Nec-1 inactive (Nec-1i), its inactive variant, and Nec-1 stable (Nec-1s), its more stable variant. We report that Nec-1 is identical to methyl-thiohydantoin-tryptophan, an inhibitor of the potent immunomodulatory enzyme indoleamine 2,3-dioxygenase (IDO). Both Nec-1 and Nec-1i inhibited human IDO, but Nec-1s did not, as predicted by molecular modeling. Therefore, Nec-1s is a more specific RIPK1 inhibitor lacking the IDO-targeting effect. Next, although Nec-1i was ∼100 × less effective than Nec-1 in inhibiting human RIPK1 kinase activity in vitro, it was only 10 times less potent than Nec-1 and Nec-1s in a mouse necroptosis assay and became even equipotent at high concentrations. Along the same line, in vivo, high doses of Nec-1, Nec-1i and Nec-1s prevented tumor necrosis factor (TNF)-induced mortality equally well, excluding the use of Nec-1i as an inactive control. Paradoxically, low doses of Nec-1 or Nec-1i, but not Nec -1s, even sensitized mice to TNF-induced mortality. Importantly, Nec-1s did not exhibit this low dose toxicity, stressing again the preferred use of Nec-1s in vivo. Our findings have important implications for the interpretation of Nec-1-based data in experimental disease models

    What is new in pediatric cardiac imaging?

    Get PDF
    Cardiac imaging has had significant influence on the science and practice of pediatric cardiology. Especially the development and improvements made in noninasive imaging techniques, like echocardiography and cardiac magnetic resonance imaging (MRI), have been extremely important. Technical advancements in the field of medical imaging are quickly being made. This review will focus on some of the important evolutions in pediatric cardiac imaging. Techniques such as intracardiac echocardiography, 3D echocardiography, and tissue Doppler imaging are relatively new echocardiographic techniques, which further optimize the anatomical and functional aspects of congenital heart disease. Also, the current standing of cardiac MRI and cardiac computerized tomography will be discussed. Finally, the recent European efforts to organize training and accreditation in pediatric echocardiography are highlighted

    The incidence of interstitial lung disease 1995–2005: a Danish nationwide population-based study

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Current data on incidence of interstitial lung diseases (ILDs) are sparse and concerns about an increasing trend have been raised. We examined incidence rates (IRs) of ILDs and changes in IRs between 1995 and 2005.</p> <p>Methods</p> <p>All persons with a first-time hospital discharge or outpatient diagnosis of ILD were identified through the Danish National Registry of Patients, which covers all Danish hospitals. Crude and age-standardised IRs were computed for ILD overall, as well as stratified by ILD subcategories.</p> <p>Results</p> <p>A total of 21,765 patients with ILD were identified. Between 1995 and 1998 the overall standardised IR of ILD decreased from 27.14 (95% CI 25.82–28.46) per 100,000 person-years to 19.36 (95% CI 18.26–20.46) per 100,000 person-years. After 1998 the IR increased considerably, peaking at 34.34 (95% CI 32.84–35.85) per 100,000 person-years in 2002. Subsequently there was a slight decrease. The highest IR was observed in the non-specific category "Respiratory disorders in diseases classified elsewhere". By ILD subcategory, the greatest average increase during the study period was observed in "Respiratory disorders in diseases classified elsewhere".</p> <p>Conclusion</p> <p>The incidence rate of ILD in Denmark increased during the study period, most pronounced for ILDs associated with systemic diseases.</p

    Can Echocardiographic Findings Predict Falls in Older Persons?

    Get PDF
    Background. The European and American guidelines state the need for echocardiography in patients with syncope. 50% of older adults with syncope present with a fall. Nonetheless, up to now no data have been published addressing echocardiographic abnormalities in older fallers. Method and Findings. In order to determine the association between echocardiographic abnormalities and falls in older adults, we performed a prospective cohort study, in which 215 new consecutive referrals (age 77.4 SD 6.0) of a geriatric outpatient clinic of a Dutch university hospital were included. During the previous year, 139 had experienced a fall. At baseline, all patients underwent routine two-dimensional and Doppler echocardiography. Falls were recorded during a three-month follow-up. Multivariate adjustment for compounders was performed with a Cox proportional hazards model. 557 patients (26%) fell at least once during follow-up. The adjusted hazard ratio of a fall during follow-up was 135 (95% Cl, 1.08-1.71) for pulmonary hypertension, 1.66 (95% Cl, 1.01 to 2.89) for 4-initial regurgitation, 2.41 (95% Cl, 1.32 to 4.37) for tricuspid regurgitation and 1.76 (95% Cl, 1.03 to 3.01) for pulmonary regurgitation. For aoitic regurgitation the risk of a fall was also increased, but non-significantly. (hazard ratio, 1.57 [95% Cl 0.85 to 2.92]). Trend analysis of the severity of the difterent regurgitations showed a significant relationship for mitral, tricuspid and pulmonary valve regurgitation and pulmonary hypertension. Conclusions. Echo(Dopler)cardiography can be useful in order to identify risk indicators for falling. Presence of pulmonary hypertension or regurgitation of mitral, tricuspid or pulmonary valves was associated with a higher fall risk. Our study indicates that the diagnostic work-up for falls in older adults might be improved by adding an echo(Doppler)cardiogram in selected groups

    Human Embryonic and Rat Adult Stem Cells with Primitive Endoderm-Like Phenotype Can Be Fated to Definitive Endoderm, and Finally Hepatocyte-Like Cells

    Get PDF
    Stem cell-derived hepatocytes may be an alternative cell source to treat liver diseases or to be used for pharmacological purposes. We developed a protocol that mimics mammalian liver development, to differentiate cells with pluripotent characteristics to hepatocyte-like cells. The protocol supports the stepwise differentiation of human embryonic stem cells (ESC) to cells with characteristics of primitive streak (PS)/mesendoderm (ME)/definitive endoderm (DE), hepatoblasts, and finally cells with phenotypic and functional characteristics of hepatocytes. Remarkably, the same protocol can also differentiate rat multipotent adult progenitor cells (rMAPCs) to hepatocyte-like cells, even though rMAPC are isolated clonally from cultured rat bone marrow (BM) and have characteristics of primitive endoderm cells. A fraction of rMAPCs can be fated to cells expressing genes consistent with a PS/ME/DE phenotype, preceding the acquisition of phenotypic and functional characteristics of hepatocytes. Although the hepatocyte-like progeny derived from both cell types is mixed, between 10–20% of cells are developmentally consistent with late fetal hepatocytes that have attained synthetic, storage and detoxifying functions near those of adult hepatocytes. This differentiation protocol will be useful for generating hepatocyte-like cells from rodent and human stem cells, and to gain insight into the early stages of liver development

    Cross-national variations in reported discrimination among people treated for major depression worldwide: The ASPEN/INDIGO international study

    Get PDF
    Background: No study has so far explored differences in discrimination reported by people with major depressive disorder (MDD) across countries and cultures. Aims: To (a) compare reported discrimination across different countries, and (b) explore the relative weight of individual and contextual factors in explaining levels of reported discrimination in people with MDD. Method: Cross-sectional multisite international survey (34 countries worldwide) of 1082 people with MDD. Experienced and anticipated discrimination were assessed by the Discrimination and Stigma Scale (DISC). Countries were classified according to their rating on the Human Development Index (HDI). Multilevel negative binomial and Poisson models were used. Results: People living in 'very high HDI' countries reported higher discrimination than those in 'medium/low HDI' countries. Variation in reported discrimination across countries was only partially explained by individual-level variables. The contribution of country-level variables was significant for anticipated discrimination only. Conclusions: Contextual factors play an important role in anticipated discrimination. Country-specific interventions should be implemented to prevent discrimination towards people with MDD

    Crown Plasticity and Competition for Canopy Space: A New Spatially Implicit Model Parameterized for 250 North American Tree Species

    Get PDF
    BACKGROUND: Canopy structure, which can be defined as the sum of the sizes, shapes and relative placements of the tree crowns in a forest stand, is central to all aspects of forest ecology. But there is no accepted method for deriving canopy structure from the sizes, species and biomechanical properties of the individual trees in a stand. Any such method must capture the fact that trees are highly plastic in their growth, forming tessellating crown shapes that fill all or most of the canopy space. METHODOLOGY/PRINCIPAL FINDINGS: We introduce a new, simple and rapidly-implemented model--the Ideal Tree Distribution, ITD--with tree form (height allometry and crown shape), growth plasticity, and space-filling, at its core. The ITD predicts the canopy status (in or out of canopy), crown depth, and total and exposed crown area of the trees in a stand, given their species, sizes and potential crown shapes. We use maximum likelihood methods, in conjunction with data from over 100,000 trees taken from forests across the coterminous US, to estimate ITD model parameters for 250 North American tree species. With only two free parameters per species--one aggregate parameter to describe crown shape, and one parameter to set the so-called depth bias--the model captures between-species patterns in average canopy status, crown radius, and crown depth, and within-species means of these metrics vs stem diameter. The model also predicts much of the variation in these metrics for a tree of a given species and size, resulting solely from deterministic responses to variation in stand structure. CONCLUSIONS/SIGNIFICANCE: This new model, with parameters for US tree species, opens up new possibilities for understanding and modeling forest dynamics at local and regional scales, and may provide a new way to interpret remote sensing data of forest canopies, including LIDAR and aerial photography
    corecore