297 research outputs found

    A high-sensitivity laser-pumped Mx magnetometer

    Get PDF
    Abstract.: We discuss the design and performance of a laser-pumped cesium vapor magnetometer in the Mx configuration. The device will be employed in the control and stabilization of fluctuating magnetic fields and gradients in a new experiment searching for a permanent electric dipole moment of the neutron. We have determined the intrinsic sensitivity of the device to be 15 fT in a 1 Hz bandwidth, limited by technical laser noise. In the shot noise limit the magnetometer can reach a sensitivity of 10 fT in a 1 Hz bandwidth. We have used the device to study the fluctuations of a stable magnetic field in a multi-layer magnetic shield for integration times in the range of 2-100 seconds. The residual fluctuations for times up to a few minutes are traced back to the instability of the power supply used to generate the fiel

    Compactness for Holomorphic Supercurves

    Full text link
    We study the compactness problem for moduli spaces of holomorphic supercurves which, being motivated by supergeometry, are perturbed such as to allow for transversality. We give an explicit construction of limiting objects for sequences of holomorphic supercurves and prove that, in important cases, every such sequence has a convergent subsequence provided that a suitable extension of the classical energy is uniformly bounded. This is a version of Gromov compactness. Finally, we introduce a topology on the moduli spaces enlarged by the limiting objects which makes these spaces compact and metrisable.Comment: 38 page

    The critically ill patient after hepatobiliary surgery

    Get PDF
    BACKGROUND: We analyzed the causes and results of utilization of critical care services in the special care unit in patients after surgical procedures performed by the hepatobiliary surgical service during a 23-month period. RESULTS: Thirty-two of 537 patients (6.0%) required postoperative admission to the special care unit. Twenty-one patients were admitted directly from operating room or from recovery room because of inability to wean from ventilator (n = 10), hypovolemic shock (n = 4), myocardial ischemia or infarction (n = 2), sepsis (n = 2), upper gastrointestinal bleeding (n = 2), and acute renal failure (n =1). Eleven postoperative patients were admitted from floor care for respiratory failure (n = 4), cardiac dysrhythmia or infarction (n = 4), sepsis (n = 2), and upper gastrointestinal bleeding (n = 1). Thirty-eight per cent of patients (n = 12) admitted to the special care unit after surgery died. By multivariate analysis, total postoperative stay in the special care unit that was greater than median total duration of stay of 4.5 days was the only independent predictor of mortality (P = 0.041). CONCLUSIONS: Respiratory failure was the predominant component of all complications after hepatobiliary surgery. No clinically useful predictors of eventual outcome could be identified

    The specificity and patterns of staining in human cells and tissues of p16INK4a antibodies demonstrate variant antigen binding

    Get PDF
    The validity of the identification and classification of human cancer using antibodies to detect biomarker proteins depends upon antibody specificity. Antibodies that bind to the tumour-suppressor protein p16INK4a are widely used for cancer diagnosis and research. In this study we examined the specificity of four commercially available anti-p16INK4a antibodies in four immunological applications. The antibodies H-156 and JC8 detected the same 16 kDa protein in western blot and immunoprecipitation tests, whereas the antibody F-12 did not detect any protein in western blot analysis or capture a protein that could be recognised by the H-156 antibody. In immunocytochemistry tests, the antibodies JC8 and H-156 detected a predominately cytoplasmic localised antigen, whose signal was depleted in p16INK4a siRNA experiments. F-12, in contrast, detected a predominately nuclear located antigen and there was no noticeable reduction in this signal after siRNA knockdown. Furthermore in immunohistochemistry tests, F-12 generated a different pattern of staining compared to the JC8 and E6H4 antibodies. These results demonstrate that three out of four commercially available p16INK4a antibodies are specific to, and indicate a mainly cytoplasmic localisation for, the p16INK4a protein. The F-12 antibody, which has been widely used in previous studies, gave different results to the other antibodies and did not demonstrate specificity to human p16INK4a. This work emphasizes the importance of the validation of commercial antibodies, aside to the previously reported use, for the full verification of immunoreaction specificity

    “Members of the Same Club”: Challenges and Decisions Faced by US IRBs in Identifying and Managing Conflicts of Interest

    Get PDF
    Conflicts of interest (COIs) in research have received increasing attention, but many questions arise about how Institutional Review Boards (IRBs) view and approach these. Methods: I conducted in-depth interviews of 2 hours each with 46 US IRB chairs, administrators, and members, exploring COI and other issues related to research integrity. I contacted leaders of 60 IRBs (every fourth one among the top 240 institutions by NIH funding), and interviewed IRB leaders from 34 of these institutions (response rate = 55%). Data were analyzed using standard qualitative methods, informed by Grounded Theory. Results: IRBs confront financial and non-financial COIs of PIs, institutions, and IRBs themselves. IRB members may seek to help, or compete with, principal investigators (PIs). Non-financial COI also often appear to be “indirect financial” conflicts based on gain (or loss) not to oneself, but to one's colleagues or larger institution. IRBs faced challenges identifying and managing these COI, and often felt that they could be more effective. IRBs' management of their own potential COI vary, and conflicted members may observe, participate, and/or vote in discussions. Individual IRB members frequently judge for themselves whether to recuse themselves. Challenges arise in addressing these issues, since institutions and PIs need funding, financial information is considered confidential, and COI can be unconscious. Conclusions: This study, the first to explore qualitatively how IRBs confront COIs and probe how IRBs confront non-financial COIs, suggests that IRBs face several types of financial and non-financial COIs, involving themselves, PIs, and institutions, and respond varyingly. These data have critical implications for practice and policy. Disclosure of indirect and non-financial COIs to subjects may not be feasible, partly since IRBs, not PIs, are conflicted. Needs exist to consider guidelines and clarifications concerning when and how, in protocol reviews, IRB members should recuse themselves from participating, observing, and/or voting

    Testing isotropy of the universe using the Ramsey resonance technique on ultracold neutron spins

    Get PDF
    Physics at the Planck scale could be revealed by looking for tiny violations of fundamental symmetries in low energy experiments. In 2008, a sensitive test of the isotropy of the Universe using has been performed with stored ultracold neutrons (UCN), this is the first clock-comparison experiment performed with free neutrons. During several days we monitored the Larmor frequency of neutron spins in a weak magnetic field using the Ramsey resonance technique. An non-zero cosmic axial field, violating rotational symmetry, would induce a daily variation of the precession frequency. Our null result constitutes one of the most stringent tests of Lorentz invariance to date.Comment: proceedings of the PNCMI2010 conferenc

    Optical Magnetometry

    Get PDF
    Some of the most sensitive methods of measuring magnetic fields utilize interactions of resonant light with atomic vapor. Recent developments in this vibrant field are improving magnetometers in many traditional areas such as measurement of geomagnetic anomalies and magnetic fields in space, and are opening the door to new ones, including, dynamical measurements of bio-magnetic fields, detection of nuclear magnetic resonance (NMR), magnetic-resonance imaging (MRI), inertial-rotation sensing, magnetic microscopy with cold atoms, and tests of fundamental symmetries of Nature.Comment: 11 pages; 4 figures; submitted to Nature Physic
    corecore