83 research outputs found

    Applications of the Cracow X-ray microprobe in tomography

    Get PDF
    A nuclear microprobe at the IFJ PAN in Cracow has found numerous applications in different fields of research, mostly in biophysics, medical sciences, geology, and material research. In order to extend the research possibilities, a new X-ray microprobe was constructed. This new microprobe consists of three experimental lines dedicated to: (i) X-ray irradiation of biological specimens, (ii) elemental analysis of samples by micro X-ray fluorescence or total reflection X-ray fluorescence methods and (iii) computer microtomography. In this paper the computer microtomography line was described. The line consists of an open type Hamamatsu L9191 X-ray tube with microfocusing to about 2 μm, a high resolution X-ray sensitive CCD camera, and a precise goniometer composed of six piezoelectric motors. Depending on the required X-ray energy, the Hamamatsu tube is used with Ti, Mo, Ag, or W targets. A small focus size and short focus-to-object distance enable to obtain images of samples with a magnification of more than 1000× and resolution of the order of 2 μm. The computer microtomography measurements are carried out using home developed codes combined with commercial software. Details of the microprobe construction and preliminary results of the computer microtomography experiments are presented

    EXAFS studies of prostate cancer cell lines

    Get PDF
    Sulphur plays a vital role in every human organism. It is known, that sulphur-bearing compounds, such as for example cysteine and glutathione, play critical roles in development and progression of many diseases. Any alteration in sulphur's biochemistry could become a precursor of serious pathological conditions. One of such condition is prostate cancer, the most frequently diagnosed malignancy in the western world and the second leading cause of cancer related death in men. The purpose of presented studies was to examine what changes occur in the nearest chemical environment of sulphur in prostate cancer cell lines in comparison to healthy cells. The Extended X-ray Absorption Fine Structure (EXAFS) spectroscopy was used, followed by theoretical calculations. The results of preliminary analysis is presented

    Preliminary investigations of elemental content, microporosity, and specific surface area of porous rocks using PIXE and X-ray microtomography techniques

    Get PDF
    Determination of physical properties of porous geological materials is of great importance for oil industry. The knowledge of rocks properties is usually obtained from porosity studies such as pore size distribution, specific surface area determination, and hydrodynamic permeability calculations. This study describes determination of elemental composition and measurements of the particular physical properties of geological samples (porous sandstone rocks) by means of the nuclear and X-ray microprobes at the Institute of Nuclear Physics, Polish Academy of Sciences in Kraków, Poland. The special emphasis has been put on the computed microtomography method. Measurements have been carried out in close cooperation with Department of Geophysics, FGGEP AGH in Kraków, Poland. Chemical composition of the Rotliegend sandstone rock samples (few millimeters diameter), extracted from a borehole at 2679.6 m, 2741.4 m and 2742.4 m depth have been investigated using the 2.2 MeV proton beam (proton induced X-ray emission technique). Next, measurements of the porosity and the specific surface area of the pore space have been carried out using the X-ray microtomography technique. Basing on microtomographic data obtained with the high spatial resolution, simulations of the fluid dynamic in the void space of porous media have been carried out. Lattice Boltzmann method in the 3DQ19 geometrical model has been used in order to predict the hydraulic permeability of the media. In order to avoid viscosity-permeability dependence the multiple-relaxation-time model with half-way bounce back boundary conditions has been used. Computing power-consuming processing has been performed with the use of modern grid infrastructure

    Bell Inequality Experiment for a High Brightness Time-Energy Entangled Source

    Get PDF
    A periodically poled MgO doped LiNbO3 (MgO:LN) non-degenerate photon pair source is utilized for spontaneous parametric down-conversion of 532 nm photons into time-energy entangled pairs of 800 and 1600 nm photons. The entangled photons are separated using previously detailed sorting optics, such that each wavelength is independently directed through one of two modified Mach-Zehnder interferometers also known as a Franson interferometer after which they are fiber-optically guided to high-efficiency photon detectors. Output from the detectors is sent to a high resolution time tagger, where coincidences between the entangled photons are recorded. By varying the length of the long path in one Mach-Zehnder interferometer, it is possible to observe high visibility sinusoidal fringes in the measured coincidence rates (while no variation is seen in single photon detection rates). These fringes due to interference between the photon probability amplitudes are indicative of a violation of the Bell inequality, and confirm inconsistencies with local hidden variable theory for the correlations of the time-energy entangled photon pairs

    Bell Inequality Experiment for a High Brightness Time-Energy Entangled Source

    Get PDF
    A periodically poled MgO - doped LiNbO3 (MgO:LN) non-degenerate photon pair source is utilized for spontaneous parametric down-conversion of 532-nanometer photons into time-energy entangled pairs of 800- and 1600-nanometer photons. The entangled photons are separated using previously detailed sorting optics, such that each wavelength is independently directed through one of two modified Mach-Zehnder interferometers - also known as a Franson interferometer - after which they are fiber-optically guided to high-efficiency photon detectors. Output from the detectors is sent to a high resolution time tagger, where coincidences between the entangled photons are recorded. By varying the length of the long path in one Mach-Zehnder interferometer, it is possible to observe high visibility sinusoidal fringes in the measured coincidence rates (while no variation is seen in single photon detection rates). These fringes - due to interference between the photon probability amplitudes - are indicative of a violation of the Bell inequality, and confirm inconsistencies with local hidden variable theory for the correlations of the time-energy entangled photon pairs

    A new Krakow scanning nuclear microprobe: performance tests and early application experienc

    No full text
    A new scanning nuclear microprobe (MP) with a short-length probe forming system was designed, installed and tested at the 3MV Van de Graaff accelerator in Krakow. The MP resolution of 3.3mm was reached for a 2.4 MeV proton beam in the high-current mode (≥100pA). The MP facility provides a local, non-destructive, quantitative elemental microanalysis using a Proton Induced X-ray Emission (PIXE) technique. As example of possible applications an analysis of a geological sample containing monazite crystals investigated by PIXE method is presented

    Model-Based Estimation of Three-Dimensional Stiffness Parameters in Photonic-Force Microscopy

    Get PDF
    We propose a system to characterize the 3-D diffusion properties of the probing bead trapped by a photonic-force microscope. We follow a model-based approach, where the model of the dynamics of the bead is given by the Langevin equation. Our procedure combines software and analog hardware to measure the corresponding stiffness matrix. We are able to estimate all its elements in real time, including off-diagonal terms. To achieve our goal, we have built a simple analog computer that performs a continuous preprocessing of the data, which can be subsequently digitized at a much lower rate than is otherwise required. We also provide an effective numerical algorithm for compensating the correlation bias introduced by a quadrant photodiode detector in the microscope. We validate our approach using simulated data and show that our bias-compensation scheme effectively improves the accuracy of the system. Moreover, we perform experiments with the real system and demonstrate real-time capabilities. Finally, we suggest a simple adjunction that would allow one to determine the mass matrix as well

    Evaluating visible derivative spectroscopy by varimax-rotated, principal component analysis of aerial hyperspectral images from the western basin of Lake Erie

    Get PDF
    The Kent State University (KSU) spectral decomposition method provides information about the spectral signals present in multispectral and hyperspectral images. Pre-processing steps that enhance signal to noise ratio (SNR) by 7.37–19.04 times, enables extraction of the environmental signals captured by the National Aeronautics and Space Administration (NASA) Glenn Research Center\u27s, second generation, Hyperspectral imager (HSI2) into multiple, independent components. We have accomplished this by pre-processing of Level 1 HSI2 data to remove stripes from the scene, followed by a combination of spectral and spatial smoothing to further increase the SNR and remove non-Lambertian features, such as waves. On average, the residual stochastic noise removed from the HSI2 images by this method is 5.43 ± 1.42%. The method also enables removal of a spectrally coherent residual atmospheric bias of 4.28 ± 0.48%, ascribed to incomplete atmospheric correction. The total noise isolated from signal by the method is thu

    Model-Based Estimation of 3-D Stiffness Parameters in Photonic-Force Microscopy

    Full text link

    Free-Space Quantum Key Distribution with a High Generation Rate KTP Waveguide Photon-Pair Source

    Get PDF
    NASA awarded Small Business Innovative Research (SBIR) contracts to AdvR, Inc to develop a high generation rate source of entangled photons that could be used to explore quantum key distribution (QKD) protocols. The final product, a photon pair source using a dual-element periodically- poled potassium titanyl phosphate (KTP) waveguide, was delivered to NASA Glenn Research Center in June of 2015. This paper describes the source, its characterization, and its performance in a B92 (Bennett, 1992) protocol QKD experiment
    corecore