69 research outputs found

    A case for considering age and sex when prescribing rest intervals in resistance training

    Get PDF
    Current resistance training position stands recommend that rest interval duration in resistance training should be prescribed based on the training goal and exercise selection. However, these recommendations are mostly extrapolated from studies that included young men as participants. Therefore, they cannot be generalized to all age groups and all resistance training programs. Herein, two overlooked, but possibly important factors for rest interval prescription are discussed: (1) age, and (2) sex of the individual. Acute studies indicate that older adults, as compared to young adults, require a shorter duration rest interval to achieve recovery between sets. Due to the sex differences in fatigability, it can be speculated that men need a longer duration rest interval than women to maintain high levels of performance. Both sex and age may be relevant variables when determining rest interval duration in resistance exercise and should not be overlooked by exercise practitioners in program design

    Coupled-resonator optical waveguides: Q-factor and disorder influence

    Full text link
    Coupled resonator optical waveguides (CROW) can significantly reduce light propagation pulse velocity due to pronounced dispersion properties. A number of interesting applications have been proposed to benefit from such slow-light propagation. Unfortunately, the inevitable presence of disorder, imperfections, and a finite Q value may heavily affect the otherwise attractive properties of CROWs. We show how finite a Q factor limits the maximum attainable group delay time; the group index is limited by Q, but equally important the feasible device length is itself also limited by damping resulting from a finite Q. Adding the additional effects of disorder to this picture, limitations become even more severe due to destructive interference phenomena, eventually in the form of Anderson localization. Simple analytical considerations demonstrate that the maximum attainable delay time in CROWs is limited by the intrinsic photon lifetime of a single resonator.Comment: Accepted for Opt. Quant. Electro

    Multi-Atomic Mirror for Perfect Reflection of Single Photons in A Wide Band of Frequency

    Full text link
    A resonant two level atom doped in one dimensional waveguide behaves as a mirror, but this single-atom "mirror" can only reflect single photon perfectly at a specific frequency. For a one dimensional coupled-resonator waveguide, we propose to extend the perfect reflection region from a specific frequency to a wide band by placing many atoms individually in the resonators in a finite coordinate region of the waveguide. Such a doped resonator array promises us to control the propagation of a practical photon wave packet with certain momentum distribution instead of a single photon, which is ideally represented by a plane wave with specific momentum. The studies based on the discrete-coordinate scattering theory display that such hybrid structure indeed provides a near-perfect reflection for single photon in a wide band. We also calculated photon group velocity distribution, which shows that the perfect reflection with wide band exactly corresponds to the stopping light region.Comment: 8 pages, 10 figure

    “Look! It’s a Computer Program! It’s an Algorithm! It’s AI!”: Does Terminology Affect Human Perceptions and Evaluations of Algorithmic Decision-Making Systems?

    Get PDF
    In the media, in policy-making, but also in research articles, algorithmic decision-making (ADM) systems are referred to as algorithms, artificial intelligence, and computer programs, amongst other terms. We hypothesize that such terminological differences can affect people’s perceptions of properties of ADM systems, people’s evaluations of systems in application contexts, and the replicability of research as findings may be influenced by terminological differences. In two studies (N = 397, N = 622), we show that terminology does indeed affect laypeople’s perceptions of system properties (e.g., perceived complexity) and evaluations of systems (e.g., trust). Our findings highlight the need to be mindful when choosing terms to describe ADM systems, because terminology can have unintended consequences, and may impact the robustness and replicability of HCI research. Additionally, our findings indicate that terminology can be used strategically (e.g., in communication about ADM systems) to influence people’s perceptions and evaluations of these systems

    A case for considering age and sex when prescribing rest intervals in resistance training

    Get PDF
    Current resistance training position stands recommend that rest interval duration in resistance training should be prescribed based on the training goal and exercise selection. However, these recommendations are mostly extrapolated from studies that included young men as participants. Therefore, they cannot be generalized to all age groups and all resistance training programs. Herein, two overlooked, but possibly important factors for rest interval prescription are discussed: (1) age, and (2) sex of the individual. Acute studies indicate that older adults, as compared to young adults, require a shorter duration rest interval to achieve recovery between sets. Due to the sex differences in fatigability, it can be speculated that men need a longer duration rest interval than women to maintain high levels of performance. Both sex and age may be relevant variables when determining rest interval duration in resistance exercise and should not be overlooked by exercise practitioners in program design

    Quantitative thermal imaging using single-pixel Si APD and MEMS mirror

    Get PDF
    Accurate quantitative temperature measurements are difficult to achieve using focal-plane array sensors. This is due to reflections inside the instrument and the difficulty of calibrating a matrix of pixels as identical radiation thermometers. Size-of-source effect (SSE), which is the dependence of an infrared temperature measurement on the area surrounding the target area, is a major contributor to this problem and cannot be reduced using glare stops. Measurements are affected by power received from outside the field-of-view (FOV), leading to increased measurement uncertainty. In this work, we present a micromechanical systems (MEMS) mirror based scanning thermal imaging camera with reduced measurement uncertainty compared to focal-plane array based systems. We demonstrate our flexible imaging approach using a Si avalanche photodiode (APD), which utilises high internal gain to enable the measurement of lower target temperatures with an effective wavelength of 1 µm and compare results with a Si photodiode. We compare measurements from our APD thermal imaging instrument against a commercial bolometer based focal-plane array camera. Our scanning approach results in a reduction in SSE related temperature error by 66 °C for the measurement of a spatially uniform 800 °C target when the target aperture diameter is increased from 10 to 20 mm. We also find that our APD instrument is capable of measuring target temperatures below 700 °C, over these near infrared wavelengths, with D* related measurement uncertainty of ± 0.5 °C

    Laser ablation ICP-MS of size-segregated atmospheric particles collected with a MOUDI cascade impactor: a proof of concept

    Get PDF
    A widely used instrument for collecting size-segregated particles is the micro-orifice uniform deposit impactor (MOUDI). In this work, a 10-stage MOUDI (cut-point diameter of 10 µm to 56 nm) was used to collect samples in Ljubljana, Slovenia, and Martinska, Croatia. Filters, collected with and without rotation, were cut in half and analyzed for nine elements (As, Cu, Fe, Ni, Mn, Pb, Sb, V, Zn) using laser ablation ICP-MS. Elemental image maps (created with ImageJ) were converted to concentrations using NIST SRM 2783. Statistical analysis of the elemental maps indicated that for submicron particles (stages 6–10), ablating 10 % of the filter (0.5 cm2, 20 min ablation time) was sufficient to give values in good agreement (±10 %) to analysis of larger parts of the filter and with good precision (RSE < 1 %). Excellent sensitivity was also observed (e.g., 20 ± 0.2 pg m−3 V). The novel use of LA-ICP-MS, together with image mapping, provided a fast and sensitive method for elemental analysis of size-segregated MOUDI filters, particularly for submicron particles

    Metal transfer to sediments, invertebrates and fish following waterborne exposure to silver nitrate or silver sulfide nanoparticles in an indoor stream mesocosm.

    Get PDF
    The fate of engineered nanomaterials in ecosystems is unclear. An aquatic stream mesocosm was explored the fate and bioaccumulation of silver sulfide nanoparticles (Ag2S NPs) compared to silver nitrate (AgNO3). The aims were to determine the total Ag in water, sediment and biota, and to evaluate the bioavailable fractions of silver in the sediment using a serial extraction method. The total Ag in the water column from a nominal daily dose of 10 μg L-1 of Ag for the AgNO3 or Ag2S NP treatments reached a plateau of around 13 and 12 μg L-1, respectively, by the end of the study. Similarly, the sediment of both Ag-treatments reached ~380 μg Ag kg-1, and with most of it being acid-extractable/labile. The biota accumulated 4-59 μg Ag g-1 dw, depending on the type of Ag-treatment and organism. The oligochaete worm, Lumbriculus variegatus, accumulated Ag from the Ag2S exposure over time, which was similar to the AgNO3 treatment by the end of the experiment. The planarian, Girardia tigrina, and the chironomid larva, Chironomus riparius, showed much higher Ag concentrations than the oligochaete worms; and with a clearer time-dependent statistically significant Ag accumulation relative to the untreated controls. For the pulmonated snail, Physa acuta, bioaccumulation of Ag from AgNO3 and Ag2S NP exposures was observed, but was lower from the nano treatment. The AgNO3 exposure caused appreciable Ag accumulation in the water flea, Daphnia magna, but accumulation was higher in the Ag2S NP treatment (reaching 59 μg g-1 dw). In the rainbow trout, Oncorhynchus mykiss, AgNO3, but not Ag2S NPs, caused total Ag concentrations to increase in the tissues. Overall, the study showed transfer of total Ag from the water column to the sediment, and Ag bioaccumulation in the biota, with Ag from Ag2S NP exposure generally being less bioavailable than that from AgNO3

    Urine-based testing for Chlamydia trachomatis among young adults in a population-based survey in Croatia: Feasibility and prevalence

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>We assessed the feasibility of collecting urine samples for testing on genital <it>Chlamydia trachomatis </it>infection in a population-based survey, and prevalence of this infection among young people aged 18-25 in Croatia. In Croatia, as in the other countries of Eastern Europe, there is a lack of data on prevalence of <it>C trachomatis </it>in the general population, including young adults.</p> <p>Methods</p> <p>We sampled participants using a nationally representative, multi-stage stratified probability sample of young men and women. Detection of <it>C trachomatis </it>DNA in urine samples was performed by using a real-time PCR assay COBAS<sup>® </sup>TaqMan<sup>® </sup>CT Test, v2.0.</p> <p>Results</p> <p>Overall, 1005 young adults participated in the behavioural part of the survey, and 27.9% men and 37.5% women who were sexually experienced agreed to provide urine samples for testing on <it>C trachomatis</it>. Using multivariate analysis, women were significantly more likely to provide urine samples than men (aOR = 1.53, 95% CI 1.14-2.06) as were those who reported no condom use at last intercourse (aOR = 1.95, 95% CI 1.44-2.62). Prevalence of <it>C trachomatis </it>infection among those who were sexually experienced was 7.3% in men and 5.3% in women.</p> <p>Conclusions</p> <p>Population-based surveys that use probabilistic sampling are a feasible way to obtain population estimates of <it>C trachomatis </it>prevalence among young adults in Croatia, but it is challenging to obtain an adequate response rate. The prevalence of <it>C trachomatis </it>among young adults in Croatia found in this study was higher than that found in other European countries with similar survey response rates.</p
    corecore