1,120 research outputs found

    XMM-Newton Observations of Radio Pulsars B0834+06 and B0826-34 and Implications for Pulsar Inner Accelerator

    Full text link
    We report the X-ray observations of two radio pulsars with drifting subpulses: B0834 + 06 and B0826 - 34 using \xmm\. PSR B0834 + 06 was detected with a total of 70 counts from the three EPIC instruments over 50 ks exposure time. Its spectrum was best described as that of a blackbody (BB) with temperature Ts=(2.00.9+2.0)×106T_s=(2.0^{+2.0}_{-0.9}) \times 10^6 K and bolometric luminosity of Lb=(8.64.4+14.2)×1028L_b=(8.6^{+14.2}_{-4.4}) \times 10^{28} erg s1^{-1}. As it is typical in pulsars with BB thermal components in their X-ray spectra, the hot spot surface area is much smaller than that of the canonical polar cap, implying a non-dipolar surface magnetic field much stronger than the dipolar component derived from the pulsar spin-down (in this case about 50 times smaller and stronger, respectively). The second pulsar PSR B0826 - 34 was not detected over 50 ks exposure time, giving an upper limit for the bolometric luminosity Lb1.4×1029L_b \leq 1.4 \times 10^{29} erg s1^{-1}. We use these data as well as the radio emission data concerned with drifting subpulses to test the Partially Screened Gap (PSG) model of the inner accelerator in pulsars.Comment: Accepted for publication by The Astrophysical Journa

    Probing the Crust of the Neutron Star in EXO 0748-676

    Get PDF
    X-ray observations of quiescent X-ray binaries have the potential to provide insight into the structure and the composition of neutron stars. EXO 0748-676 had been actively accreting for over 24 yr before its outburst ceased in late 2008. Subsequent X-ray monitoring revealed a gradual decay of the quiescent thermal emission that can be attributed to cooling of the accretion-heated neutron star crust. In this work, we report on new Chandra and Swift observations that extend the quiescent monitoring to ~5 yr post-outburst. We find that the neutron star temperature remained at ~117 eV between 2009 and 2011, but had decreased to ~110 eV in 2013. This suggests that the crust has not fully cooled yet, which is supported by the lower temperature of ~95 eV that was measured ~4 yr prior to the accretion phase in 1980. Comparing the data to thermal evolution simulations reveals that the apparent lack of cooling between 2009 and 2011 could possibly be a signature of convection driven by phase separation of light and heavy nuclei in the outer layers of the neutron star.Comment: 9 pages, 4 tables, 3 figures. Minor revisions according to referee report. Accepted to Ap

    Feature integration in natural language concepts

    Get PDF
    Two experiments measured the joint influence of three key sets of semantic features on the frequency with which artifacts (Experiment 1) or plants and creatures (Experiment 2) were categorized in familiar categories. For artifacts, current function outweighed both originally intended function and current appearance. For biological kinds, appearance and behavior, an inner biological function, and appearance and behavior of offspring all had similarly strong effects on categorization. The data were analyzed to determine whether an independent cue model or an interactive model best accounted for how the effects of the three feature sets combined. Feature integration was found to be additive for artifacts but interactive for biological kinds. In keeping with this, membership in contrasting artifact categories tended to be superadditive, indicating overlapping categories, whereas for biological kinds, it was subadditive, indicating conceptual gaps between categories. It is argued that the results underline a key domain difference between artifact and biological concepts

    Calculation of Costs of Pregnancy- and Puerperium-related Care: Experience from a Hospital in a Low-income Country

    Get PDF
    Calculation of costs of different medical and surgical services has numerous uses, which include monitoring the performance of service-delivery, setting the efficiency target, benchmarking of services across all sectors, considering investment decisions, commissioning to meet health needs, and negotiating revised levels of funding. The role of private-sector healthcare facilities has been increasing rapidly over the last decade. Despite the overall improvement in the public and private healthcare sectors in Bangladesh, lack of price benchmarking leads to patients facing unexplained price discrimination when receiving healthcare services. The aim of the study was to calculate the hospital-care cost of disease-specific cases, specifically pregnancy- and puerperium-related cases, and to indentify the practical challenges of conducting costing studies in the hospital setting in Bangladesh. A combination of micro-costing and step-down cost allocation was used for collecting information on the cost items and, ultimately, for calculating the unit cost for each diagnostic case. Data were collected from the hospital records of 162 patients having 11 different clinical diagnoses. Caesarean section due to maternal and foetal complications was the most expensive type of case whereas the length of stay due to complications was the major driver of cost. Some constraints in keeping hospital medical records and accounting practices were observed. Despite these constraints, the findings of the study indicate that it is feasible to carry out a large-scale study to further explore the costs of different hospital-care services

    Radiation Hardness of Thin Low Gain Avalanche Detectors

    Full text link
    Low Gain Avalanche Detectors (LGAD) are based on a n++-p+-p-p++ structure where an appropriate doping of the multiplication layer (p+) leads to high enough electric fields for impact ionization. Gain factors of few tens in charge significantly improve the resolution of timing measurements, particularly for thin detectors, where the timing performance was shown to be limited by Landau fluctuations. The main obstacle for their operation is the decrease of gain with irradiation, attributed to effective acceptor removal in the gain layer. Sets of thin sensors were produced by two different producers on different substrates, with different gain layer doping profiles and thicknesses (45, 50 and 80 um). Their performance in terms of gain/collected charge and leakage current was compared before and after irradiation with neutrons and pions up to the equivalent fluences of 5e15 cm-2. Transient Current Technique and charge collection measurements with LHC speed electronics were employed to characterize the detectors. The thin LGAD sensors were shown to perform much better than sensors of standard thickness (~300 um) and offer larger charge collection with respect to detectors without gain layer for fluences <2e15 cm-2. Larger initial gain prolongs the beneficial performance of LGADs. Pions were found to be more damaging than neutrons at the same equivalent fluence, while no significant difference was found between different producers. At very high fluences and bias voltages the gain appears due to deep acceptors in the bulk, hence also in thin standard detectors

    What determines auditory similarity? The effect of stimulus group and methodology.

    Get PDF
    Two experiments on the internal representation of auditory stimuli compared the pairwise and grouping methodologies as means of deriving similarity judgements. A total of 45 undergraduate students participated in each experiment, judging the similarity of short auditory stimuli, using one of the methodologies. The experiments support and extend Bonebright's (1996) findings, using a further 60 stimuli. Results from both methodologies highlight the importance of category information and acoustic features, such as root mean square (RMS) power and pitch, in similarity judgements. Results showed that the grouping task is a viable alternative to the pairwise task with N > 20 sounds whilst highlighting subtle differences, such as cluster tightness, between the different task results. The grouping task is more likely to yield category information as underlying similarity judgements

    Neutron rich matter, neutron stars, and their crusts

    Full text link
    Neutron rich matter is at the heart of many fundamental questions in Nuclear Physics and Astrophysics. What are the high density phases of QCD? Where did the chemical elements come from? What is the structure of many compact and energetic objects in the heavens, and what determines their electromagnetic, neutrino, and gravitational-wave radiations? Moreover, neutron rich matter is being studied with an extraordinary variety of new tools such as Facility for Rare Isotope Beams (FRIB) and the Laser Interferometer Gravitational Wave Observatory (LIGO). We describe the Lead Radius Experiment (PREX) that is using parity violation to measure the neutron radius in 208Pb. This has important implications for neutron stars and their crusts. Using large scale molecular dynamics, we model the formation of solids in both white dwarfs and neutron stars. We find neutron star crust to be the strongest material known, some 10 billion times stronger than steel. It can support mountains on rotating neutron stars large enough to generate detectable gravitational waves. Finally, we describe a new equation of state for supernova and neutron star merger simulations based on the Virial expansion at low densities, and large scale relativistic mean field calculations.Comment: 10 pages, 2 figures, Plenary talk International Nuclear Physics Conference 2010, Vancouver, C
    corecore