79 research outputs found

    Validation of 3D echocardiographic volume detection of left atrium by human cadaveric casts

    Get PDF
    Background: Left atrial volume is a prognostic factor in cardiac pathologies. We aimed to validate left atrial volume detection with 3D and 2D echocardiography (3DE and 2DE) by human cadaveric casts. 3DE facilitates measurement of atrial volume without geometrical assumptions or dependence on imaging angle in contrast to 2DE methods. Methods: For method validation, six water-filled balloons were submerged in a 20-l water tank and their volumes were measured with 3DE. Seven human cadaveric left atrial casts were prepared of silicone and were transformed into ultrasound-permeable casts. Casts were imaged in the same setting, so that 3DE and 2DE of casts represented transthoracic apical view. Left ventricle analysis softwares GE 4D Auto LVQ and TomTec 4D LV-Function were used for 3DE volumetry. Results; Balloon volumes ranged 37 to 255ml (mean 126 ml). 3DE resulted in an excellent volumetric agreement with balloon volumes, absolute bias was -3.7 ml (95% CI -5.9 to -1.4). Atrial cast volumes were 38 to 94 ml (mean 56.6 ml). 3DE and 2DE volumes were excellently correlated with cast volumes (r = 0.96 to 0.99). Biases were for GE 4D LVQ - 0.7 ml (95% CI -6.1 to 4.6), TomTec 4D LV-Function 3.3 ml (-1.9 to 8.5) and 2DE 2.9 ml (-4.0 to 9.9). 3DE resulted in lower limits of agreement and showed no volume-related bias in contrast to area-length method. Conclusions: We conclude that measurement of human cadaveric left atrial cast volumes by 3DE is in excellent agreement with true cast volumes.Peer reviewe

    Left Atrial Dynamics Is Altered in Young Adults With Cryptogenic Ischemic Stroke : A Case-Control Study Utilizing Advanced Echocardiography

    Get PDF
    BACKGROUND: Ischemic stroke in young individuals often remains cryptogenic. Some of these strokes likely originate from the heart, and atrial fibrosis might be one of the etiological mechanisms. In this pilot study, we investigated whether advanced echocardiography findings of the left atrium (LA) of young cryptogenic stroke patients differ from those of stroke--free controls. METHODS AND RESULTS: We recruited 30 cryptogenic ischemic stroke patients aged 18 to 49 years and 30 age--and sex-matched stroke--free controls among participants of the SECRETO (Searching for Explanations for Cryptogenic Stroke in the Young: Revealing the Etiology, Triggers, and Outcome) study (NCT01934725). We measured basic left ventricular parameters and detailed measures of the LA, including 4--dimensional volumetry, speckle tracking epsilon, strain rate, and LA appendix orifice variation. Data were compared as continuous parameters and by tertiles. Compared with controls, stroke patients had smaller LA reservoir volumes (10.2 [interquartile range, 5.4] versus 13.2 [5.4] mL; P= 0.030) and smaller positive epsilon values (17.8 [8.5] versus 20.8 [10.1]; P= 0.023). In the tertile analysis, stroke patients had significantly lower left atrial appendage orifice variation (3.88 [0.75] versus 4.35 [0.90] mm; P=0.043), lower LA cyclic volume change (9.2 [2.8] versus 12.8 [3.5] mL; P=0.023), and lower LA contraction peak strain rate (-1.8 [0.6] versus -2.3 [0.6]; P=0.021). We found no statistically significant differences in left ventricular measures. CONCLUSIONS: This preliminary comparison suggests altered LA dynamics in young patients with cryptogenic ischemic stroke, and thus that LA wall pathology might contribute to these strokes. Our results await confirmation in a larger sample.Peer reviewe

    MRI-derived cardiac washout is slowed in the left ventricle and associated with left ventricular non-compaction in young patients with cryptogenic ischemic stroke

    Get PDF
    To elucidate underlying disease mechanisms, we compared transition of gadolinium-based contrast agent bolus in cardiac chambers in magnetic resonance imaging between young patents with cryptogenic ischemic stroke and stroke-free controls. We included 30 patients aged 18-50 years with cryptogenic ischemic stroke from the prospective Searching for Explanations for Cryptogenic Stroke in the Young: Revealing the Etiology, Triggers and Outcome (NCT01934725) study and 30 age- and gender-matched stroke-free controls. Dynamic contrast-enhanced T1-weighted first-pass perfusion images were acquired at 1.5 T and analyzed for transit time variables, area under curves, relative blood flow, and maximum and minimum enhancement rates in left atrial appendage, left atrium, and left ventricle. These data were compared with previously published left ventricular non-compaction data of the same study population. Arrival time of contrast agent bolus in superior vena cava was similar in patients and controls (6.7[2.0] vs. 7.1[2.5] cardiac cycles, P = 0.626). Arrival and peak times showed comparable characteristics in patients and controls (P > 0.535). The minimum enhancement rate of the left ventricle was lower in patients than in controls (- 28 +/- 11 vs. - 36 +/- 13 1/(cardiac cycle), P = 0.012). Area under curves, relative blood flow, and other enhancement rates showed no significant differences between patients and controls (P > 0.107). Relative blood flow of cardiac chambers correlated with non-compacted left ventricular volume ratio (P < 0.011). Our results indicate slower washout of contrast agent and blood flow stagnation in the left ventricle of young patients with cryptogenic ischemic stroke. The washout was associated with left ventricular non-compaction, suggesting conditions favoring formation of intraventricular thrombosis.Peer reviewe

    Evidence of subtle left ventricular systolic dysfunction in cryptogenic stroke in the young

    Get PDF
    Introduction: Ischemic stroke in young patients often remains cryptogenic, that is, no underlying reason can be found. Some of these strokes may originate in the heart. Left ventricular (LV) dynamic volumetry and strain analysis are relatively new and promising methods for evaluating LV function. Methods: In this pilot study, we recruited 30 young (18-50 years) patients with cryptogenic ischemic stroke and 30 age- and sex-matched controls from the SECRETO study (NCT01934725). The LV systolic function was assessed by LV volumetry (ejection fraction, peak emptying rate, and time to peak emptying rate). The longitudinal systolic function was assessed by speckle tracking strain and strain rate imaging, and by tissue velocity imaging derived MAD (mitral annular displacement) and septal S'. Results: Stroke patients had less vigorous global longitudinal strain (median -18.9, interquartile range 3.3), compared to healthy controls (median -20.0, interquartile range 2.8), P = .010. There was no statistically significant differences in septal S', MAD, global longitudinal strain rate, or dynamic volumetry-derived parameters between the two groups. Conclusions: Young cryptogenic stroke patients have subtly altered systolic function compared to healthy controls, found merely with longitudinal strain analysis. This infers that the heart may play a role in the pathogenesis of cryptogenic ischemic stroke.Peer reviewe

    Diastolic function in young patients with cryptogenic stroke : A case-control pilot study

    Get PDF
    Background Ischaemic stroke in young individuals often remains cryptogenic. In this pilot study, we investigated, whether advanced echocardiography methods could find differences in the diastolic function between young cryptogenic stroke patients and stroke-free controls. Methods We recruited 30 cryptogenic ischaemic stroke patients aged 18-49 and 30 age- and sex-matched stroke-free controls among participants of the Searching for Explanations for Cryptogenic Stroke in the Young: Revealing the Etiology, Triggers, and Outcome (SECRETO) study (NCT01934725). We measured diastolic function parameters derived from speckle tracking strain rate, Doppler techniques and 4D volumetry. We also performed statistical analyses comparing only the highest and lowest tertile of cases and controls for each parameter. Results None of our patients or controls had diastolic dysfunction according to ASE/EACVI criteria. However, compared to stroke-free controls, the stroke patient group had lower E/A ratio of mitral inflow, lower lateral and mean e', lower A/a' ratio, lower strain rate in early diastole and lower speckle tracking-derived e/a ratio. When comparing the lowest tertiles, patients also had a lower peak filling rate by 4D volumetry, a lower peak early filling fraction (fraction of left ventricular filling during early diastole), and lower velocities in a series of the tissue Doppler-derived diastolic parameters and blood flow/tissue velocity ratios. Conclusion Our study displayed subtle differences in diastolic function between patients and stroke-free controls, which may play a role in early-onset cryptogenic stroke. The differences were clearer when the lowest tertiles were compared, suggesting that there is a subgroup of young cryptogenic stroke patients with subclinical heart disease.Peer reviewe

    Sydämen kaikututkimuksia avoterveydenhuollossa?

    Get PDF
    Vertaisarvioitu. English summary• Sydämen kaikututkimus on tärkeä diagnostinen työkalu sydänsairauksien selvittelyssä. • Hyvinkään, Espoon ja Kauniaisten terveyskeskuslääkärit voivat tilata näitä tutkimuksia ostopalveluna Hyvinkään ja Jorvin sairaaloista. • Uusi tai aiemmin tutkimaton systolinen sivuääni oli selvästi yleisin läheteaihe, kun käytiin läpi sata peräkkäistä sydämen kaikututkimusta, jotka oli tehty perusterveydenhuollon lähetteellä. • Hento systolinen sivuääni ilman muita sydänsairauden löydöksiä tai oireita ei edellytä kaikututkimusta, mutta diastolinen sivuääni kannattaa aina tutkia

    A comprehensive model for measuring real-life cost-effectiveness in eyecare : automation in care and evaluation of system (aces-rwm (TM))

    Get PDF
    This paper describes a holistic, yet simple and comprehensible, ecosystem model to deal with multiple and complex challenges in eyecare. It aims at producing the best possible wellbeing and eyesight with the available resources. When targeting to improve the real-world cost-effectiveness, what gets done in everyday practice needs be measured routinely, efficiently and unselectively. Collection of all real-world data of all patients will enable evaluation and comparison of eyecare systems and departments between themselves nationally and internationally. The concept advocates a strategy to optimize real-life effectiveness, sustainability and outcomes of the service delivery in ophthalmology. The model consists of three components: (1) resource-governing principles (i.e., to deal with increasing demand and limited resources), (2) real-world monitoring (i.e., to collect structured real-world data utilizing automation and visualization of clinical parameters, health-related quality of life and costs), and (3) digital innovation strategy (i.e., to evaluate and benchmark real-world outcomes and cost-effectiveness). The core value and strength of the model lies in the consensus and collaboration of all Finnish university eye clinics to collect and evaluate the uniformly structured real-world outcomes data. In addition to ophthalmology, the approach is adaptable to any medical discipline to efficiently generate real-world insights and resilience in health systems.Peer reviewe

    Left ventricular non-compaction as a potential source for cryptogenic ischemic stroke in the young : A case-control study

    Get PDF
    Background Up to 50% of ischemic strokes in the young after thorough diagnostic work-up remain cryptogenic or associated with low-risk sources of cardioembolism such as patent foramen ovale (PFO). We studied with cardiac magnetic resonance (CMR) imaging, whether left ventricular (LV) non-compaction-a possible source for embolic stroke due to sluggish blood flow in deep intertrabecular recesses-is associated with cryptogenic strokes in the young. Methods Searching for Explanations for Cryptogenic Stroke in the Young: Revealing the Etiology, Triggers, and Outcome (SECRETO; NCT01934725) is an international prospective multicenter case-control study of young adults (aged 18-49 years) presenting with an imaging-positive first-ever ischemic stroke of undetermined etiology. In this pilot substudy, 30 cases and 30 age- and sex-matched stroke-free controls were examined with CMR. Transcranial Doppler (TCD) bubble test was performed to evaluate the presence and magnitude of right-to-left shunt (RLS). Results There were no significant differences in LV volumes, masses or systolic function between cases and controls; none of the participants had non-compaction cardiomyopathy. Semi-automated assessment of LV non-compaction was highly reproducible. Non-compacted LV mass (median 14.0 [interquartile range 12.6-16.0] g/m(2)vs. 12.7 [10.4-16.6] g/m(2), p = 0.045), the ratio of non-compacted to compacted LV mass (mean 25.6 +/- 4.2% vs. 22.8 +/- 6.0%, p = 0.015) and the percentage of non-compacted LV volume (mean 17.6 +/- 2.9% vs. 15.7 +/- 3.8%, p = 0.004) were higher in cases compared to controls. In a multivariate conditional logistic regression model including non-compacted LV volume, RLS and body mass index, the percentage of non-compacted LV volume (odds ratio [OR] 1.55, 95% confidence interval [CI] 1.10-2.18, p = 0.011) and the presence of RLS (OR 11.94, 95% CI 1.14-124.94, p = 0.038) were independently associated with cryptogenic ischemic stroke. Conclusions LV non-compaction is associated with a heightened risk of cryptogenic ischemic stroke in young adults, independent of concomitant RLS and in the absence of cardiomyopathy.Peer reviewe
    corecore