25 research outputs found

    Small renal masses in kidney transplantation : Overview of clinical impact and management in donors and recipients

    Get PDF
    Kidney transplantation is the best replacement treatment for the end-stage renal disease. Currently, the imbalance between the number of patients on a transplant list and the number of organs available constitutes the crucial limitation of this approach. To expand the pool of organs amenable for transplantation, kidneys coming from older patients have been employed; however, the combination of these organs in conjunction with the chronic use of immunosuppressive therapy increases the risk of incidence of graft small renal tumors. This narrative review aims to provide the state of the art on the clinical impact and management of incidentally diagnosed small renal tumors in either donors or recipients. According to the most updated evidence, the use of grafts with a small renal mass, after bench table tumor excision, may be considered a safe option for high-risk patients in hemodialysis. On the other hand, an early small renal mass finding on periodic ultrasound-evaluation in the graft should allow to perform a conservative treatment in order to preserve renal function. Finally, in case of a renal tumor in native kidney, a radical nephrectomy is usually recommended

    Discrimination, Reliability, Sensitivity, and Specificity of Robotic Surgical Proficiency Assessment With Global Evaluative Assessment of Robotic Skills and Binary Scoring Metrics: Results From a Randomized Controlled Trial

    Get PDF
    Objective: To compare binary metrics and Global Evaluative Assessment of Robotic Skills (GEARS) evaluations of training outcome assessments for reliability, sensitivity, and specificity. Background: GEARS–Likert-scale skills assessment are a widely accepted tool for robotic surgical training outcome evaluations. Proficiency-based progression (PBP) training is another methodology but uses binary performance metrics for evaluations. Methods: In a prospective, randomized, and blinded study, we compared conventional with PBP training for a robotic suturing, knot-tying anastomosis task. Thirty-six surgical residents from 16 Belgium residency programs were randomized. In the skills laboratory, the PBP group trained until they demonstrated a quantitatively defined proficiency benchmark. The conventional group were yoked to the same training time but without the proficiency requirement. The final trial was video recorded and assessed with binary metrics and GEARS by robotic surgeons blinded to individual, group, and residency program. Sensitivity and specificity of the two assessment methods were evaluated with area under the curve (AUC) and receiver operating characteristics (ROC) curves. Results: The PBP group made 42% fewer objectively assessed performance errors than the conventional group (P &lt; 0.001) and scored 15% better on the GEARS assessment (P = 0.033). The mean interrater reliability for binary metrics and GEARS was 0.87 and 0.38, respectively. Binary total error metrics AUC was 97% and for GEARS 85%. With a sensitivity threshold of 0.8, false positives rates were 3% and 25% for, respectively, the binary and GEARS assessments. Conclusions: Binary metrics for scoring a robotic VUA task demonstrated better psychometric properties than the GEARS assessment. </jats:sec

    Adrenal Gland Primary Neuroblastoma in an Adult Patient: A Case Report and Literature Review

    No full text
    Neuroblastoma (NB) is an undifferentiated malignant tumor of the sympathetic ganglia, occurring in children under 5 years of age. However, it is a rare histology in adult patients, occurring once per every 10 million patients per year. We present the case of a 68-year-old male patient presented to our department for right lumbar pain, asthenia, loss of weight and altered general status. The contrast-enhanced abdominal computer tomography revealed bilateral adrenal tumoral masses of 149 mm and 82 mm on the right and left sides, respectively, with invasion of the surrounding organs. The patient underwent right 3D laparoscopic adrenalectomy and right radical nephrectomy. The pathological result concluded that the excised tumor was a neuroblastoma of the adrenal gland. The patient followed adjuvant oncological treatment; however, due to disease progression, he passed away 22 months after the surgery. To our knowledge, less than 100 cases of adrenal NB in adult patients have been published, the eldest case being diagnosed at 75 years of age; meanwhile, the largest reported tumor measured 200 mm, and was excised through open surgery. Minimally invasive techniques have been limited so far to smaller, organ-confined diseases, thus making the present case the largest adrenal NB removed entirely laparoscopically. Neuroblastoma in the adult population is a rare finding, with worse prognosis compared to pediatric patients. The available literature does not provide enough data for standardized, multimodal management, as the patients are treated following adapted pediatric protocols, thus reinforcing the need for international, multidisciplinary boards for rare tumors

    Singularity Analysis and Geometric Optimization of a 6-DOF Parallel Robot for SILS

    No full text
    The paper presents the singularity analysis and the geometric optimization of a 6-DOF (Degrees of Freedom) parallel robot for SILS (Single-Incision Laparoscopic Surgery). Based on a defined set of input/output constraint equations, the singularities of the parallel robotic system are determined and geometrically interpreted. Then, the geometric parameters (e.g., the lengths of the mechanism links) for the 6-DOF parallel robot for SILS are optimized such that the robotic system complies with an operational workspace defined in correlation with the SILS task. A numerical analysis of the singularities showed that the operational workspace is singularity free. Furthermore, numerical simulations validate the parallel robot for the next developing stages (e.g., designing and prototyping stages)

    Preoperative Predicting the WHO/ISUP Nuclear Grade of Clear Cell Renal Cell Carcinoma by Computed Tomography-Based Radiomics Features

    No full text
    Nuclear grade is important for treatment selection and prognosis in patients with clear cell renal cell carcinoma (ccRCC). This study aimed to determine the ability of preoperative four-phase multiphasic multidetector computed tomography (MDCT)-based radiomics features to predict the WHO/ISUP nuclear grade. In all 102 patients with histologically confirmed ccRCC, the training set (n = 62) and validation set (n = 40) were randomly assigned. In both datasets, patients were categorized according to the WHO/ISUP grading system into low-grade ccRCC (grades 1 and 2) and high-grade ccRCC (grades 3 and 4). The feature selection process consisted of three steps, including least absolute shrinkage and selection operator (LASSO) regression analysis, and the radiomics scores were developed using 48 radiomics features (10 in the unenhanced phase, 17 in the corticomedullary (CM) phase, 14 in the nephrographic (NP) phase, and 7 in the excretory phase). The radiomics score (Rad-Score) derived from the CM phase achieved the best predictive ability, with a sensitivity, specificity, and an area under the curve (AUC) of 90.91%, 95.00%, and 0.97 in the training set. In the validation set, the Rad-Score derived from the NP phase achieved the best predictive ability, with a sensitivity, specificity, and an AUC of 72.73%, 85.30%, and 0.84. We constructed a complex model, adding the radiomics score for each of the phases to the clinicoradiological characteristics, and found significantly better performance in the discrimination of the nuclear grades of ccRCCs in all MDCT phases. The highest AUC of 0.99 (95% CI, 0.92&ndash;1.00, p &lt; 0.0001) was demonstrated for the CM phase. Our results showed that the MDCT radiomics features may play a role as potential imaging biomarkers to preoperatively predict the WHO/ISUP grade of ccRCCs

    On the development of an innovative surgical parallel robotic system

    No full text
    International audienceThis paper presents the development of the experimental model of an innovative parallel robot for Single Incision Laparoscopic Surgery (SILS). The proposed solution implements the master-slave architecture. The research is mostly focused on the development of the slave robotic system, which is managed using two readily available 3D Space Mouse devices. The user interface is thoughtfully crafted to align with the specific requirements of surgeons. Additionally, we present a detail analysis of the motion trajectory of the slave robot, generated based on the kinematic model integrated within the control system is also presented

    Integration of Virtual Reality in the Control System of an Innovative Medical Robot for Single-Incision Laparoscopic Surgery

    No full text
    In recent years, there has been an expansion in the development of simulators that use virtual reality (VR) as a learning tool. In surgery where robots are used, VR serves as a revolutionary technology to help medical doctors train in using these robotic systems and accumulate knowledge without risk. This article presents a study in which VR is used to create a simulator designed for robotically assisted single-uniport surgery. The control of the surgical robotic system is achieved using voice commands for laparoscopic camera positioning and via a user interface developed using the Visual Studio program that connects a wristband equipped with sensors attached to the user’s hand for the manipulation of the active instruments. The software consists of the user interface and the VR application via the TCP/IP communication protocol. To study the evolution of the performance of this virtual system, 15 people were involved in the experimental evaluation of the VR simulator built for the robotic surgical system, having to complete a medically relevant task. The experimental data validated the initial solution, which will be further developed

    Combined Systematic and MRI-US Fusion Prostate Biopsy Has the Highest Grading Accuracy When Compared to Final Pathology

    No full text
    Background and objectives: Systematic prostate biopsy (SB) has a low Gleason group (GG) accuracy when compared to final pathology. This may negatively impact the inclusion of patients into specific risk groups and treatment choice. The aim of our study was to assess the GG accuracy of magnetic resonance imaging-ultrasound (MRI-US) fusion prostate biopsy. Materials and Methods: Of a cohort of minimally invasive radical prostatectomy (RP), we selected all patients who were diagnosed with prostate cancer (PCa) via MRI-US fusion biopsy (n = 115). Results: Combined biopsy had the highest rate for GG concordance (61.7% vs. 60.4% for SB vs. 45.3% for MRI-US fusion biopsy) and the lowest for upgrading (20.9% vs. 24.5% for SB vs. 34.9% for MRI-US fusion biopsy), p &lt; 0.0001. No clinical data were predictive for upgrading or downgrading at final pathology. Locally advanced PCa was associated with a high Prostate Imaging-Reporting and Data System (PIRADS) score (p = 0.0014) and higher percentages of positive biopsy cores (PBC)/targeted (p = 0.0002) and PBC/total (p = 0.01). Positive surgical margins were correlated with higher percentages of PBC/systematic (p = 0.003) and PBC/total (p = 0.009). Conclusions: Pre-biopsy prostate MRI improves GG concordance between biopsy and RP. Combined biopsy provides the highest grading accuracy when compared to final pathology. Targeted and systematic biopsy data are predictive for adverse pathologic outcomes
    corecore