759 research outputs found

    A study of incremental sheet forming by using water jet

    Get PDF
    In this work, a variant of the incremental sheet forming (ISF) process, namely the incremental sheet forming by using water jet (ISF-WJ), was studied. In the investigation, an ISF-WJ prototype machine was designed and developed. Different design concepts of the water jet nozzle were proposed and evaluated to achieve the maximum forming pressure by performing computational fluid dynamic (CFD) simulations. Based on the forming pressure distribution modeled by CFD simulations, finite element (FE) models were developed to study the sheet deformation behavior under the ISF-WJ process condition. Based on the understanding gained from the numerical study, experiments were conducted to validate the ISF-WJ process and the developed prototype machine. The results suggest that ISF-WJ is a feasible process to achieve improved surface finish of thin sheet parts. In addition, this study has found that water jet pressure plays an important role in preventing sheet wrinkling and obtaining an accurate geometry of formed parts

    Association between asymptomatic hyperuricemia and new-onset chronic kidney disease in Japanese male workers: a long-term retrospective cohort study

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Hyperuricemia is prevalent in patients with chronic kidney disease (CKD). We explored the hypothesis that asymptmatic hyperuricemia may be associated with new-onset CKD.</p> <p>Methods</p> <p>The participants were all male factory workers in Kanagawa, Japan (n = 1,285). All were over 40 years of age and had undergone annual health examinations from 1990 to 2007. Individuals with a history of gouty attacks were excluded from the study. A retrospective cohort study was conducted by following the estimated glomerular filtration rate (eGFR) for each participant over a maximum period of 18 years. The endpoint was new-onset CKD defined as eGFR < 60 mL/min/1.73 m<sup>2</sup>. The associations between new-onset CKD and the presence of hyperuricemia, low serum high-density lipoprotein cholesterol, hypertension, diabetes, and obesity were analyzed.</p> <p>Results</p> <p>The mean (± standard deviation) follow-up period was 95.2 (± 66.7) months, and new-onset CKD was observed in 100 participants (7.8%) during this follow-up. Cox proportional hazards model revealed that the hazard ratio of new-onset CKD due to hyperuricemia, low serum high-density lipoprotein cholesterol, hypertension and obesity were 3.99 (95% confidence interval: 2.59-6.15), 1.69 (1.00-2.86), 2.00 (1.29-3.11) and 1.35 (0.87-2.10), respectively. Concerning hyperuricemia, low serum high-density lipoprotein cholesterol, hypertension and obesity, the log-rank tests showed <it>P </it>values of < 0.01, 0.01, < 0.01 and < 0.01, respectively.</p> <p>Conclusion</p> <p>The results of this study suggest that asymptomatic hyperuricemia is a predictive factor for new-onset CKD for Japanese male workers.</p

    Localization of a continuous CO2 leak from an isotropic flat-surface structure using acoustic emission detection and near-field beamforming techniques

    Get PDF
    Seal capacity is of great importance for the safety operation of pressurized vessels. It is crucial to locate the leak hole timely and accurately for reasons of safety and maintenance. This paper presents the principle and application of a linear acoustic emission sensor array and a near-field beamforming technique to identify the location of a continuous CO2 leak from an isotropic flat-surface structure on a pressurized vessel in the Carbon Capture and Storage system. Acoustic signals generated by the leak hole are collected using a linear high-frequency sensor array. Time-frequency analysis and a narrow-band filtering technique are deployed to extract effective information about the leak. The impacts of various factors on the performance of the localization technique are simulated, compared and discussed, including the number of sensors, distance between the leak hole and sensor array and spacing between adjacent sensors. Experiments were carried out on a laboratory-scale test rig to assess the effectiveness and operability of the proposed method. The results obtained suggest that the proposed method is capable of providing accurate and reliable localization of a continuous CO2 leak

    Diagnostic yield of renal biopsies: a retrospective single center review

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Previous studies have examined the spectrum of diseases identified with a kidney biopsy and the complications of the procedure. However, few studies have examined the utility of the test to clarify the diagnosis and guide treatment of pediatric patients. This retrospective, single-center chart review was performed to test the hypothesis that at least 80% of native kidney biopsies provide clinically valuable information that rationally guides diagnosis and patient management.</p> <p>Methods</p> <p>200 biopsies performed between January 1, 2000 and June 30, 2008 were reviewed. A scheme composed of six categories was devised to classify the utility of each kidney biopsy.</p> <p>Results</p> <p>196 complete case files were available for review. Twenty-four (12.2%) biopsies did not shed light on the diagnosis and were unhelpful in patient management – 21 biopsies (10.7%) were non-diagnostic and 3 (1.5%) failed to yield enough tissue for examination. The number of unhelpful biopsies did not cluster in any specific disease entity.</p> <p>Conclusion</p> <p>Our findings provide guidance to nephrologists about the total risk of a kidney biopsy, including uninformative results, when seeking informed consent for the procedure. The results suggest an appropriate balance has been reached which maximizes the use of kidney biopsies while minimizing the risk of this invasive procedure (word count: 202).</p

    High prevalence of chronic kidney disease in Iran: a large population-based study

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Chronic kidney disease (CKD) is a global public health threat, associated with an alarming increase in morbidity and mortality. The importance is the worldwide increase in its incidence and prevalence.</p> <p>Methods</p> <p>In this cross-sectional study, we estimate the prevalence and determine the associated factors of chronic kidney disease in a representative sample of 10063 participants aged over 20 years, in Tehran, Iran. Chronic kidney disease was defined as estimated glomerular filtration rate less than 60 mL/min/1.73 m2. Glomerular filtration rate was estimated from abbreviated prediction equation provided by the Modification of Diet in Renal Disease study (MDRD).</p> <p>Results</p> <p>Overall prevalence of CKD with the abbreviated MDRD equation was 18.9% (95% confidence interval (CI) 18.2, 20.6). Age adjusted prevalence of CKD was 14.9% (95%CI 14.2, 15.6). Factors associated to CKD include age(years)(odds ratio(OR) 1.1, 95% CI 1.0 to 1.2), female gender (OR 3.1, 95% CI 2.6, 3.7), BMI (BMI 25 to <30 OR 1.5, 95% CI 1.3, 1.8 and BMI ≥ 30 OR 1.6, 95% CI 1.3, 2.0), high waist circumference (OR 1.2, 95% CI 1.1, 1.4), hypertension (OR 1.2, 95% CI 1.1, 1.4), and dyslipidemia (OR 1.3, 95% CI 1.1, 1.5).</p> <p>Conclusion</p> <p>CKD with its high prevalence poses a definite health threat in Iran.</p

    A simple, high-throughput, colourimetric, field applicable loop-mediated isothermal amplification (HtLAMP) assay for malaria elimination.

    Get PDF
    BACKGROUND: To detect all malaria infections in elimination settings sensitive, high throughput and field deployable diagnostic tools are required. Loop-mediated isothermal amplification (LAMP) represents a possible field-applicable molecular diagnostic tool. However, current LAMP platforms are limited by their capacity for high throughput. METHODS: A high-throughput LAMP (HtLAMP) platform amplifying mitochondrial targets using a 96-well microtitre plate platform, processing 85 samples and 11 controls, using hydroxynaphtholblue as a colourimetric indicator was optimized for the detection of malaria parasites. Objective confirmation of visually detectable colour change results was made using a spectrophotometer. A dilution series of laboratory-cultured 3D7 Plasmodium falciparum parasites was used to determine the limit of detection of the HtLAMP assay, using P. falciparum (HtLAMP-Pf) and Plasmodium genus (HtLAMP-Pg) primers, on whole blood and filter paper, and using different DNA extraction protocols. The diagnostic accuracy of HtLAMP was validated using clinical samples from Papua New Guinea, Malaysia, Ghana and The Gambia and its field applicability was evaluated in Kota Marudu district hospital, Sabah, Malaysia. RESULTS: The HtLAMP assay proved to be a simple method generating a visually-detectable blue and purple colour change that could be objectively confirmed in a spectrophotometer at a wavelength of 600 nm. When compared with PCR, overall HtLAMP-Pg had a sensitivity of 98 % (n = 260/266, 95 % CI 95-99) and specificity 83 % (n = 15/18, 95 % CI 59-96). HtLAMP-Pf had a sensitivity of 97 % (n = 124/128, 95 % CI 92-99) and specificity of 96 % (n = 151/157, 95 % CI 92-99). A validation study in a regional hospital laboratory demonstrated ease of performance and interpretation of the HtLAMP assay. HtLAMP-Pf performed in this field setting had a sensitivity of 100 % (n = 17/17, 95 % CI 80-100) and specificity of 95 % (n = 123/128, 95 % CI 90-98) compared with multiplex PCR. HtLAMP-Pf also performed well on filter paper samples from asymptomatic Ghanaian children with a sensitivity of 88 % (n = 23/25, 95 % CI 69-97). CONCLUSION: This colourimetric HtLAMP assay holds much promise as a field applicable molecular diagnostic tool for the purpose of malaria elimination

    Renal histomorphology in dogs with pyometra and control dogs, and long term clinical outcome with respect to signs of kidney disease

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Age-related changes in renal histomorphology are described, while the presence of glomerulonephritis in dogs with pyometra is controversial in current literature.</p> <p>Methods</p> <p>Dogs with pyometra were examined retrospectively for evidence of secondary renal damage and persisting renal disease through two retrospective studies. In Study 1, light microscopic lesions of renal tissue were graded and compared in nineteen dogs with pyometra and thirteen age-matched control bitches. In Study 2, forty-one owners of dogs with pyometra were interviewed approximately 8 years after surgery for evidence ofclinical signs of renal failure in order to document causes of death/euthanasia.</p> <p>Results</p> <p>Interstitial inflammation and tubular atrophy were more pronounced in dogs with pyometra than in the control animals. Glomerular lesions classified as glomerular sclerosis were present in both groups. No unequivocal light microscopic features of glomerulonephritis were observed in bitches in any of the groups.</p> <p>Two bitches severely proteinuric at the time of surgery had developed end stage renal disease within 3 years. In five of the bitches polyuria persisted after surgery. Most bitches did not show signs of kidney disease at the time of death/euthanasia.</p> <p>Conclusion</p> <p>Tubulointerstitial inflammation was observed, but glomerular damage beyond age-related changes could not be demonstrated by light microscopy in the dogs with pyometra. However, severe proteinuria after surgery may predispose to development of renal failure.</p
    • …
    corecore