144 research outputs found

    The influence of clearance on friction, lubrication and squeaking in large diameter metal-on-metal hip replacements

    Get PDF
    Large diameter metal-on-metal bearings (MOM) are becoming increasingly popular, addressing the needs of young and more active patients. Clinical data has shown excellent short-to-mid-term results, though incidences of transient squeaking have been noted between implantation and up to 2 years post-operative. Geometric design features, such as clearance, have been significant in influencing the performance of the bearings. Sets of MOM bearings with different clearances were investigated in this study using a hip friction simulator to examine the influence of clearance on friction, lubrication and squeaking. The friction factor was found to be highest in the largest clearance bearings under all test conditions. The incidence of squeaking was also highest in the large clearance bearings, with all bearings in this group squeaking throughout the study. A very low incidence of squeaking was observed in the other two clearance groups. The measured lubricating film was found to be lowest in the large clearance bearings. This study suggests that increasing the bearing clearance results in reduced lubricant film thickness, increased friction and an increased incidence of squeaking

    An in vitro simulation model to assess the severity of edge loading and wear, due to variations in component positioning in hip joint replacements

    No full text
    The aim of this study was to develop a preclinical in vitro method to predict the occurrence and severity of edge loading condition associated with the dynamic separation of the centres of the head and cup (in the absence of impingement) for variations in surgical positioning of the cup. Specifically, this study investigated the effect of both the variations in the medial–lateral translational mismatch between the centres of the femoral head and acetabular cup and the variations in the cup inclination angles on the occurrence and magnitude of the dynamic separation, the severity of edge loading, and the wear rate of ceramic‐on‐ceramic hip replacement bearings in a multi‐station hip joint simulator during a walking gait cycle. An increased mismatch between the centres of rotation of the femoral head and acetabular cup resulted in an increased level of dynamic separation and an increase in the severity of edge loading condition which led to increased wear rate in ceramic‐on‐ceramic bearings. Additionally for a given translational mismatch, an increase in the cup inclination angle gave rise to increased dynamic separation, worst edge loading conditions, and increased wear. To reduce the occurrence and severity of edge loading, the relative positions (the mismatch) of the centres of rotation of the head and the cup should be considered alongside the rotational position of the acetabular cup. This study has considered the combination of mechanical and tribological factors for the first time in the medial–lateral axis only, involving one rotational angle (inclination) and one translational mismatch

    A comparison of friction in 28 mm conventional and 55 mm resurfacing metal-on-metal hip replacements

    Get PDF
    Total hip replacement has been a common, successful surgical intervention for many years. However, it has long been considered unsatisfactory for younger, more active patients due to the limited survivorship of conventional implants employing polyethylene. Larger resurfacing implants were developed to preserve bone stock and improve stability, however, early metal-on-polyethylene implants failed due to high wear. More recent developments, utilizing a metal-on-metal bearing, have encouraging short- to medium-term clinical performance. Concerns exist regarding the increased sliding distance and frictional torque generated within a larger diameter bearing. A large diameter metal-on-metal surface replacement was contrasted with a conventional 28 mm diameter implant with the same bearing material combination using a pendulum friction simulator. Studies were performed under different swing-phase load and lubrication conditions. The larger diameter bearing exhibited the lower friction factor under all test conditions, although the measured frictional torque was higher. Increasing swing-phase load was shown to cause an increase in friction factor in all tests. Increased serum concentration resulted in a reduction in friction factor for both bearings. Variation of the friction factor with the head diameter suggested that fluid-film lubrication contributed to the reduction of friction

    Detailed Inspection of Metal Implants

    Get PDF
    Detailed visual inspection of metal hips is the first step in retrieval analysis. In this study a systematic visual inspection protocol was developed to quantify bearing surface changes and their associations with material loss was investigated. Simple and multiple linear regression models found that moderate surface scratching, discolouration, haziness and the size of visible wear scars were all significantly associated with material loss (R2 = 5% - 73%, p<0.05). Visual inspection is not a substitute for measurement of material loss but an understanding of bearing surface changes may offer unique clues as to the mechanisms of failure of retrieved hips

    The Elite-Plus stem migrates more than the flanged Charnley stem: A clinical, radiographic, and radiostereometric analysis of 114 patients with an average of 7 years follow-up

    Get PDF
    Background and purpose The Charnley Elite-Plus stem was introduced in 1993 as a presumed improvement of the flanged Charnley stem. We started this study in 1996 to investigate the migratory pattern of the Elite-Plus stem. Patients and methods We followed 114 patients with osteoarthritis and a primary total hip replacement with the Elite-Plus stem. Mean age at the time of operation was 64 (50-76) years. The mean follow-up time was 6.5 (2-7) years. Radiographs were evaluated with respect to cementing technique, migration, and wear measured by radiostereometry (RSA). Results The stem survival was 98% (CI: 96-100) at 7 years and 92% (CI: 86-97) at 10 years. Mean migration of the femoral head was 0.35 mm (SD 0.3) medially, 0.51 mm (SD 0.6) distally, and 1.1 mm (SD 1.8) in the dorsal direction. Mean total point motion was 1.7 mm (SD 1.7). The migration of the stems stabilized after 5 years in the medial and dorsal directions, but continued to subside slightly. Migration along any of the axes was higher if the cementing technique was inferior. Interpretation Patients with a Charnley Elite-Plus stem and defects in the cement mantle or other signs of inferior implantation technique should be carefully monitored

    Validation of a 3D CT method for measurement of linear wear of acetabular cups: A hip simulator study

    Get PDF
    Background We evaluated the accuracy and repeatability of a 3D method for polyethylene acetabular cup wear measurements using computed tomography (CT). We propose that the method be used for clinical in vivo assessment of wear in acetabular cups. Material and methods Ultra-high molecular weight polyethylene cups with a titanium mesh molded on the outside were subjected to wear using a hip simulator. Before and after wear, they were (1) imaged with a CT scanner using a phantom model device, (2) measured using a coordinate measurement machine (CMM), and (3) weighed. CMM was used as the reference method for measurement of femoral head penetration into the cup and for comparison with CT, and gravimetric measurements were used as a reference for both CT and CMM. Femoral head penetration and wear vector angle were studied. The head diameters were also measured with both CMM and CT. The repeatability of the method proposed was evaluated with two repeated measurements using different positions of the phantom in the CT scanner. Results The accuracy of the 3D CT method for evaluation of linear wear was 0.51 mm and the repeatability was 0.39 mm. Repeatability for wear vector angle was 17?. Interpretation This study of metal-meshed hip-simulated acetabular cups shows that CT has the capacity for reliable measurement of linear wear of acetabular cups at a clinically relevant level of accuracy

    High Annual Risk of Tuberculosis Infection among Nursing Students in South India: A Cohort Study

    Get PDF
    Background: Nurses in developing countries are frequently exposed to infectious tuberculosis (TB) patients, and have a high prevalence of TB infection. To estimate the incidence of new TB infection, we recruited a cohort of young nursing trainees at the Christian Medical College in Southern India. Annual tuberculin skin testing (TST) was conducted to assess the annual risk of TB infection (ARTI) in this cohort. Methodology/Principal Findings: 436 nursing students completed baseline two-step TST testing in 2007 and 217 were TST-negative and therefore eligible for repeat testing in 2008. 181 subjects completed a detailed questionnaire on exposure to tuberculosis from workplace and social contacts. A physician verified the questionnaire and clinical log book and screened the subjects for symptoms of active TB. The majority of nursing students (96.7%) were females, almost 84% were under 22 years of age, and 80% had BCG scars. Among those students who underwent repeat testing in 2008, 14 had TST conversions using the ATS/CDC/IDSA conversion definition of 10 mm or greater increase over baseline. The ARTI was therefore estimated as 7.8% (95%CI: 4.3-12.8%). This was significantly higher than the national average ARTI of 1.5%. Sputum collection and caring for pulmonary TB patients were both high risk activities that were associated with TST conversions in this young nursing cohort. Conclusions: Our study showed a high ARTI among young nursing trainees, substantially higher than that seen in the general Indian population. Indian healthcare providers and the Indian Revised National TB Control Programme will need to implement internationally recommended TB infection control interventions to protect its health care workforce

    Using PCR-Based Detection and Genotyping to Trace Streptococcus salivarius Meningitis Outbreak Strain to Oral Flora of Radiology Physician Assistant

    Get PDF
    We recently investigated three cases of bacterial meningitis that were reported from a midwestern radiology clinic where facemasks were not worn during spinal injection of contrast agent during myelography procedures. Using pulsed field gel electrophoresis we linked a case strain of S. salivarius to an oral specimen of a radiology physician assistant (RPA). We also used a real-time PCR assay to detect S. salivarius DNA within a culture-negative cerebrospinal fluid (CSF) specimen. Here we extend this investigation through using a nested PCR/sequencing strategy to link the culture-negative CSF specimen to the case strain. We also provide validation of the real-time PCR assay used, demonstrating that it is not solely specific for Streptococcus salivarius, but is also highly sensitive for detection of the closely related oral species Streptococcus vestibularis. Through using multilocus sequence typing and 16S rDNA sequencing we further strengthen the link between the CSF case isolate and the RPA carriage isolate. We also demonstrate that the newly characterized strains from this study are distinct from previously characterized S. salivarius strains associated with carriage and meningitis

    EBM in primary care: a qualitative multicenter study in Spain

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Evidence based medicine (EBM) has made a substantial impact on primary care in Spain over the last few years. However, little research has been done into family physicians (FPs)' attitudes related to EBM. The present study investigates FPs' perceptions of EBM in the primary care context.</p> <p>Methods</p> <p>This study used qualitative methodology. Information was obtained from 8 focus groups composed of 67 FPs from 47 health centers in 4 autonomous regions in Spain. Intentional sampling considered participants' previous education in EBM, and their experience as tutors in family medicine or working groups' members of the Spanish Society of Family Practice. Sociological discourse analysis was used with the support of the MAXqda software. Results were validated by means of triangulation among researchers and contrast with participants.</p> <p>Results</p> <p>Findings were grouped into three main areas: 1) The tug-of-war between the "science" of EBM and "experience" in the search for good clinical practice in primary care; 2) The development of EBM sensemaking as a reaction to contextual factors and interests; 3) The paradox of doubt and trust in the new EBM experts.</p> <p>The meaning of EBM was dynamically constructed within the primary care context. FPs did not consider good clinical practice was limited to the vision of science that EBM represents. Its use appeared to be conditioned by several factors that transcended the common concept of barriers. Along with concerns about its objectivity, participants showed a tendency to see EBM as the use of simplified guidelines developed by EBM experts.</p> <p>Conclusions</p> <p>The identification of science with EBM and its recognition as a useful but insufficient tool for the good clinical practice requires rethinking new meanings of evidence within the primary care reality. Beyond the barriers related to accessing and putting into practice the EBM, its reactive use can determine FPs' questions and EBM development in a direction not always centred on patients' needs. The questioning of experts' authority as a pillar of EBM could be challenged by the emergence of new kinds of EBM texts and experts to believe in.</p

    Global Priorities for Conserving the Evolutionary History of Sharks, Rays, and Chimaeras

    Get PDF
    In an era of accelerated biodiversity loss and limited conservation resources, systematic prioritization of species and places is essential. In terrestrial vertebrates, evolutionary distinctness has been used to identify species and locations that embody the greatest share of evolutionary history. We estimate evolutionary distinctness for a large marine vertebrate radiation on a dated taxon-complete tree for all 1,192 chondrichthyan fishes (sharks, rays and chimaeras) by augmenting a new 610-species molecular phylogeny using taxonomic constraints. Chondrichthyans are by far the most evolutionarily distinct of all major radiations of jawed vertebrates—the average species embodies 26 million years of unique evolutionary history. With this metric, we identify 21 countries with the highest richness, endemism and evolutionary distinctness of threatened species as targets for conservation prioritization. On average, threatened chondrichthyans are more evolutionarily distinct—further motivating improved conservation, fisheries management and trade regulation to avoid significant pruning of the chondrichthyan tree of life
    corecore