2,366 research outputs found

    Class I Gap-formation in Highly-viscous Glass-ionomer Restorations: Delayed vs Immediate Polishing

    Get PDF
    This in vitro study evaluated the effects of delayed versus immediate polishing to permit maturation of interfacial gap-formation around highly viscous conventional glass-ionomer cement (HV-GIC) in Class I restorations, together with determining the associated mechanical properties. Cavity preparations were made on the occlusal surfaces of premolars. Three HV-GICs (Fuji IX GP, GlasIonomer FX-II and Ketac Molar) and one conventional glass-ionomer cement (C-GIC, Fuji II, as a control) were studied, with specimen subgroups (n=10) for each property measured. After polishing, either immediately (six minutes) after setting or after 24 hours storage, the restored teeth were sectioned in a mesiodistal direction through the center of the model Class I restorations. The presence or absence of interfacial-gaps was measured at 1000× magnification at 14 points (each 0.5-mm apart) along the cavity restoration interface (n=10; total points measured per group = 140). Marginal gaps were similarly measured in Teflon molds as swelling data, together with shear-bond-strength to enamel and dentin, flexural strength and moduli. For three HV-GICs and one C-GIC, significant differences (p<0.05) in gap-incidence were observed between polishing immediately and after one-day storage. In the former case, 80–100 gaps were found. In the latter case, only 9–21 gaps were observed. For all materials, their shear-bond-strengths, flexural strength and moduli increased significantly after 24-hour storage.</p

    Class I Gap-formation in Highly-viscous Glass-ionomer Restorations: Delayed vs Immediate Polishing

    Get PDF
    This in vitro study evaluated the effects of delayed versus immediate polishing to permit maturation of interfacial gap-formation around highly viscous conventional glass-ionomer cement (HV-GIC) in Class I restorations, together with determining the associated mechanical properties. Cavity preparations were made on the occlusal surfaces of premolars. Three HV-GICs (Fuji IX GP, GlasIonomer FX-II and Ketac Molar) and one conventional glass-ionomer cement (C-GIC, Fuji II, as a control) were studied, with specimen subgroups (n=10) for each property measured. After polishing, either immediately (six minutes) after setting or after 24 hours storage, the restored teeth were sectioned in a mesiodistal direction through the center of the model Class I restorations. The presence or absence of interfacial-gaps was measured at 1000× magnification at 14 points (each 0.5-mm apart) along the cavity restoration interface (n=10; total points measured per group = 140). Marginal gaps were similarly measured in Teflon molds as swelling data, together with shear-bond-strength to enamel and dentin, flexural strength and moduli. For three HV-GICs and one C-GIC, significant differences (p<0.05) in gap-incidence were observed between polishing immediately and after one-day storage. In the former case, 80–100 gaps were found. In the latter case, only 9–21 gaps were observed. For all materials, their shear-bond-strengths, flexural strength and moduli increased significantly after 24-hour storage.</p

    Antiulcerative properties of crude polyphenols and juice of apple, and Chinese quince extracts

    Get PDF
    ArticleFOOD CHEMISTRY. 108(2): 488-495 (2008)journal articl

    Coupling of Josephson flux-flow oscillators to an external RC load

    Full text link
    We investigate by numerical simulations the behavior of the power dissipated in a resistive load capacitively coupled to a Josephson flux flow oscillator and compare the results to those obtained for a d.c. coupled purely resistive load. Assuming realistic values for the parameters R and C, both in the high- and in the low-Tc case the power is large enough to allow the operation of such a device in applications.Comment: uuencoded, gzipped tar archive containing 11 pages of REVTeX text + 4 PostScript figures. To appear in Supercond. Sci. Techno

    Performance of MAX-DOAS measurements of aerosols at Tsukuba, Japan: a comparison with lidar and sky radiometer measurements

    No full text
    International audienceGround-based Multi-Axis Differential Optical Absorption Spectroscopy (MAX-DOAS) measurements were performed at Tsukuba, Japan (36.1° N, 140.1° E), in November?December 2006. The measured spectra of scattered sunlight are analyzed by DOAS and optimal estimation methods to retrieve the aerosol optical depth (?) and the vertical profile of the aerosol extinction coefficient (?) at 476 nm in the lower troposphere. We characterize these retrieved quantities through comparisons with coincident lidar and sky radiometer measurements. The retrieved ? values for layers of 0?1 and 1?2 km agree with lidar data to within 30% and 60%, respectively, for most cases, including partly cloudy conditions. Results similar to ? at 0?1 km are obtained for the retrieved ? values, demonstrating that MAX-DOAS provides the new, unique aerosol dataset in the lower troposphere

    Theory of Bi2_2Sr2_2CaCu2_2O8+δ_{8+\delta} Cross-Whisker Josephson Junctions

    Full text link
    Takano {\it et al.} [Phys. Rev. B {\bf 65}, 140513 (2002) and unpublished] made Josephson junctions from single crystal whiskers of Bi2_2Sr2_2CaCu2_2O8+δ_{8+\delta} crossed an angle ϕ0\phi_0 about the cc axis. From the mesa structures that formed at the cross-whisker interface, they inferred a critical current density Jc(ϕ0)J_c(\phi_0). Like the single crystal results of Li {\it et al.} [Phys. Rev. Lett. {\bf 83}, 4160 (1999)], we show that the whisker data are unlikely to result from a predominantly d-wave order parameter. However, unlike the single crystals, these results, if correct, require the whisker c-axis transport to be coherent.Comment: 5 pages, 4 figures, accepted for publication in Physical Review

    Improvement of polyuria, bladder sensation and bladder capacity following renal transplantation

    Get PDF
    The definitive version is available at www.blackwell-synergy.com.ArticleInternational Journal of Urology. 13(5): 616-618 (2006)journal articl
    • …
    corecore