93 research outputs found

    In-situ real-time monitoring of spurious modes in HE11_{11} transmission lines using multi-hole couplers in miter bends

    Get PDF
    Transmission of high-power millimeter waves for ECRH is often realised with oversized corrugated circular waveguides. Coupling from the gyrotron source to the waveguide is typically done via matching mirrors in free space. Small alignment errors of the system lead to the excitation of higher-order modes inside the waveguide beside the main transmission mode HE11_{11}. Tose modes have comparably higher losses and can in worst case result in local fields exceeding the breakdown limit of the medium inside the waveguide. For alignment control over the whole pulse duration of the gyrotron, a set of hole-array couplers placed into a miter bend mirror probes the field inside the waveguide. The arrays are designed to detect the marker modes for beam offset and tilt (LP(e=0)^{(e=0)}11_{11}) as well as for beam waist mismatch (LP02_{02}). In addition, a main mode coupler sensitive mostly for the HE11_{11} content is used as a power monitor. By maximizing the signal of the power monitor and minimizing the content of marker modes, a first-order optimization of the coupling from free space to the waveguide can be achieved. Signal processing of the 140 GHz information is done at kHz range after downmixing, using a frequency shifted part of the power monitor signal. As the measurement system is placed in a miter bend mirror, it can also be easily installed at various locations along the transmission line to check for possible misalignments of the waveguide connections between miter bends. Simulation and low power experimental results will be shown

    High Harmonic ECH Experiment for Extension of Heating Parameter Regime in LHD

    Get PDF
    High harmonic electron cyclotron resonance heating (ECH) can extend the plasma heating region to higher density and higher β compared to the normal heating scenario. In this study, the heating characteristics of the second-harmonic ordinary (O2) and third-harmonic extraordinary (X3) modes and the possible extension of heating regime are experimentally confirmed. At the same time, a comparative study using ray-tracing calculation was performed in the realistic three-dimensional configuration of the Large Helical Device. The O2 mode heating showed a 40% absorption rate even above the X2 mode cut-off density. The X3 mode heating using powerful 77 GHz gyrotrons demonstrated an increase of about 40% in the central electron temperature in the plasmas at β-value of about 1%. These results were quantitatively explained to some extent by ray-tracing calculations

    Experimental Results for Electron Bernstein Wave Heating in the Large Helical Device

    Get PDF
    Electron cyclotron heating (ECH) using electron Bernstein waves (EBWs) was studied in the large helical device (LHD). Oblique launching of the slow extraordinary (SX-) mode from the high field side and oblique launching of the ordinary (O-) mode from the low field side were adopted to excite EBWs in the LHD by using electron cyclotron (EC) wave antennas installed apart from the plasma surface. Increases in the stored energy and electron temperature were observed for both cases of launching. These launching methods for ECH using EBWs (EBWH) is promising for high-density operation in future helical fusion devices instead of conventional ECH by normal electromagnetic modes

    Spatial resolved high-energy particle diagnostic system using time-of-flight neutral particle analyzer in Large Helical Device

    Get PDF
    The time-of-flight-type neutral particle analyzer has an ability of horizontal scanning from 40 to 100° of the pitch angle. The information from the spatially resolved energy spectrum gives not only the ion temperature but also the information of the particle confinement and the electric field in plasmas. We have been studying the energy distributions at various magnetic configurations in the neutral beam injection (NBI) plasma. The spatially resolved energy spectra can be observed during long discharges of the NBI plasma by continuous scanning of the neutral particle analyzer. The shape of spectra is almost similar from 44° to 53°. However, the spectra from 55° are strongly varied. They reflect the injection pitch angle of the beam. The pitch angle scanning experiment during the long discharge of NBI plasma has also been made under the reversal of the magnetic field direction. NBI2 becomes counter injected with the reversal. We can easily observe the difference between co- and counter injections of NBI. During the electron cyclotron heating in the low-density plasma for the formation of the internal thermal barrier, large neutral particle increase or decease can be observed. The degree of the increase/decrease depends on the energy and the density. The reason for the variation of the particle flux is that the orbit of the trapped particle changes due to the electric field formed by the strong electron cyclotron heating

    Investigations of the radial propagation of blob-like structure in a non-confined electron cyclotron resonance heated plasma on Q-shu University Experiment with a Steady-State Spherical Tokamak

    Get PDF
    A study of radial propagation and electric fields induced by charge separation in blob-like structures has been performed in a non-confined cylindrical electron cyclotron resonance heating plasma on Q-shu University Experiment with a Steady-State Spherical Tokamak using a fast-speed camera and a Langmuir probe. The radial propagation of the blob-like structures is found to be driven by E × B drift. Moreover, these blob-like structures were found to have been accelerated, and the property of the measured radial velocities agrees with the previously proposed model [C. Theiler et al., Phys. Rev. Lett. 103, 065001 (2009)]. Although the dependence of the radial velocity on the connection length of the magnetic field appeared to be different, a plausible explanation based on enhanced short-circuiting of the current path can be proposed

    High Energy Particle Measurements during Long Discharge in LHD

    Get PDF
    The spatial resolved energy spectra can be observed during a long discharge of NBI plasma bycontinuously scanning the neutral particle analyzer. In these discharges, the plasmas are initiated by the ECH heating, after that NBI#2 (Co-injection) sustains the plasma during 40-60 seconds. The scanned pitch angle is from 44 degrees to 74 degrees. The injected neutral beam (hydrogen) energy of NBI#2 is only 130 keV because the original ion source polarity is negative. The shape of spectra is almost similar from 44 degrees to 53 degrees. However the spectra from 55 degrees are strongly varied. It reflects the injection pitch angle of the beam according to the simulation (53 degrees ot R* = 3.75 m in simulation). The beam keeps the pitch angle at incidence until the beam energy becomes to the energy, which the pitch angle scattering is occurred by the energy loss due to the electron collision. The low flux region can be observed around 10-15 keV, which is 15 times of the electron temperature. The energy region may be equal to the energy at which the pitch angle scattering is occurred. At the energy, the particle is scattered by the collision with the plasma ions and some of particles may run away from the plasma because they have a possibility to enter the loss cone. According to the simulation, the loss cone can be expected at the 10 keV with the small angular dependence. The depth of the loss cone is deep at the small pitch angle. The hollow in the spectrum may be concluded to be the loss cone as the tendency is almost agreed with the experimental result

    Impurity emission characteristics of long pulse discharges in Large Helical Device

    Get PDF
    Line spectra from intrinsic impurity ions have been monitored during the three kinds of long-pulse discharges (ICH, ECH, NBI). Constant emission from the iron impurity shows no preferential accumulation of iron ion during the long-pulse operations. Stable Doppler ion temperature has been also measured from Fe XX, C V and C III spectra

    Recent Results from LHD Experiment with Emphasis on Relation to Theory from Experimentalist’s View

    Get PDF
    he Large Helical Device (LHD) has been extending an operational regime of net-current free plasmas towardsthe fusion relevant condition with taking advantage of a net current-free heliotron concept and employing a superconducting coil system. Heating capability has exceeded 10 MW and the central ion and electron temperatureshave reached 7 and 10 keV, respectively. The maximum value of β and pulse length have been extended to 3.2% and 150 s, respectively. Many encouraging physical findings have been obtained. Topics from recent experiments, which should be emphasized from the aspect of theoretical approaches, are reviewed. Those are (1) Prominent features in the inward shifted configuration, i.e., mitigation of an ideal interchange mode in the configuration with magnetic hill, and confinement improvement due to suppression of both anomalous and neoclassical transport, (2) Demonstration ofbifurcation of radial electric field and associated formation of an internal transport barrier, and (3) Dynamics of magnetic islands and clarification of the role of separatrix

    Endothelial Dysfunction, Increased Arterial Stiffness, and Cardiovascular Risk Prediction in Patients With Coronary Artery Disease: FMD‐J (Flow‐Mediated Dilation Japan) Study A

    Get PDF
    BackgroundThe usefulness of vascular function tests for management of patients with a history of coronary artery disease is not fully known.Methods and ResultsWe measured flow‐mediated vasodilation (FMD) and brachial–ankle pulse wave velocity (baPWV) in 462 patients with coronary artery disease for assessment of the predictive value of FMD and baPWV for future cardiovascular events in a prospective multicenter observational study. The first primary outcome was coronary events, and the second primary outcome was a composite of coronary events, stroke, heart failure, and sudden death. During a median follow‐up period of 49.2 months, the first primary outcome occurred in 56 patients and the second primary outcome occurred in 66 patients. FMD above the cutoff value of 7.1%, derived from receiver‐operator curve analyses for the first and second primary outcomes, was significantly associated with lower risk of the first (hazard ratio, 0.27; 95% confidence interval, 0.06–0.74; P=0.008) and second (hazard ratio, 0.32; 95% confidence interval, 0.09–0.79; P=0.01) primary outcomes. baPWV above the cutoff value of 1731 cm/s was significantly associated with higher risk of the first (hazard ratio, 1.86; 95% confidence interval, 1.01–3.44; P=0.04) and second (hazard ratio, 2.19; 95% confidence interval, 1.23–3.90; P=0.008) primary outcomes. Among 4 groups stratified according to the combination of cutoff values of FMD and baPWV, stepwise increases in the calculated risk ratio for the first and second primary outcomes were observed.ConclusionsIn patients with coronary artery disease, both FMD and baPWV were significant predictors of cardiovascular events. The combination of FMD and baPWV provided further cardiovascular risk stratification
    corecore