419 research outputs found

    Spacecraft Electrical Connector Selection and Application Processes

    Get PDF
    This assessment was initiated by the NASA Engineering & Safety Center (NESC) after a number of recent "high profile" connector problems, the most visible and publicized of these being the problem with the Space Shuttle's Engine Cut-Off System cryogenic feed-thru connector. The NESC commissioned a review of NASA's connector selection and application processes for space flight applications, including how lessons learned and past problem records are fed back into the processes to avoid recurring issues. Team members were primarily from the various NASA Centers and included connector and electrical parts specialists. The commissioned study was conducted on spacecraft connector selection and application processes at NASA Centers. The team also compared the NASA spacecraft connector selection and application process to the military process, identified recent high profile connector failures, and analyzed problem report data looking for trends and common occurrences. The team characterized NASA's connector problem experience into a list of top connector issues based on anecdotal evidence of a system's impact and commonality between Centers. These top issues are as follows, in no particular rank order: electrically shorted, bent and/or recessed contact pins, contact pin/socket contamination leading to electrically open or intermittencies, connector plating corrosion or corrosion of connector components, low or inadequate contact pin retention forces, contact crimp failures, unmated connectors and mis-wiring due to workmanship errors during installation or maintenance, loose connectors due to manufacturing defects such as wavy washer and worn bayonet retention, damaged connector elastomeric seals and cryogenic connector failure. A survey was also conducted of SAE Connector AE-8C1 committee members regarding their experience relative to the NASA concerns on connectors. The most common responses in order of occurrence were contact retention, plating issues, worn-out or damaged coupling mechanisms, bent pins, contact crimp barrel cracking and torn seals. In addition to these common themes, responses included issues with markings, dimensional errors on the build, contact/socket damage (handling), manufacturing defects and customer misapplication and mishandling. The NESC team concluded that considering the large quantity and wide variety of connectors successfully flown on human and robotic space applications, the number of failures is quite low. However, "high profile" failures with significant cost, schedule, safety, and/or mission success impacts continue to occur. It was also concluded that connector failures occur throughout a system's life-cycle with the majority of connector issues application related. A number of recommendations were identified for improving NASA connector selection processes and overall space connector reliability and performance

    Axial segregation behaviour of a reacting biomass particle in fluidized bed reactors: experimental results and model validation

    Get PDF
    Axial segregation behaviour of a single biomass particle in a lab-scale bubbling fluidized bed has been investigated from both experimental and modelling perspectives. Experiments were conducted using beech wood particles of different sizes, ranging from 8 to 12 mm under either oxidizing or inert conditions. The fluidized bed reactor was operated at temperatures and fluidization velocity ratios, U/Umf, in the range of 500–650 °C and 1–2, respectively. A one-dimensional model has been developed to predict the axial location of the particle over time, taking into account both dynamic and thermal conversion mechanisms. X-ray imaging techniques allowed to identify endogenous bubbles released during devolatilization and carry out direct measurements of their size. This information was used to propose an expression for the lift force acting on the fuel particle. The model showed very accurate predictions and the segregation behaviour of the fuel particle appeared to be independent of the nature of the fluidizing medium

    Relevant and selective activity of Pancratium illyricum L. against Candida albicans clinical isolates: a combined effect on yeast growth and virulence

    Get PDF
    BACKGROUND: Alkaloids present in plants of the Amaryllidaceae family are secondary metabolites of high biological interest, possessing a wide range of pharmacological activities. In the search for new plant-derived compounds with antimicrobial activities, two alkaloid extracts obtained from bulbs and leaves of Pancratium illyricum L., a plant of the Amarillydaceae family, were tested for their effect on bacterial and yeast growth. METHODS: The broth microdilution susceptibility test was applied to study the effect of plant extracts on the growth of reference bacterial strains and Candida albicans reference and clinical isolates strains. Extracts obtained from the different parts of the plant were tested and compared with the pure components identified in the extracts. Since matrix metalloproteinase enzymes play a role in the dissemination process of Candida albicans, the effect of the bulb extract and pure alkaloids on in vitro collagenase activity was tested. Cell viability test was carried out on human embryo lung fibroblasts (HEL 299). RESULTS: Whilst both extracts did not show any inhibitory activity against neither Gram positive nor Gram negative bacteria, a strong antifungal activity was detected, in particular for the bulb extract. All clinical isolates were susceptible to the growth inhibitory activity of the bulb extract, with endpoint IC50 values ranging from 1.22 to 78 ÎŒg/mL. The pure alkaloids lycorine and vittatine, identified as components of the extract, were also assayed for their capacity of inhibiting the yeast growth, and lycorine turned very active, with endpoint IC50 values ranging from 0.89 to 28.5 ÎŒg/mL. A potent inhibition of the in vitro collagenase activity was found in the presence of the bulb extract, and this effect was much higher than that exerted by the pure alkaloids. Viability of cell lines tested was not affected by the extract. CONCLUSIONS: Taken together, results suggest that the extract of Pancratium illyricum may act as antifungal agent both directly on the yeast growth and by altering the tissue invasion process

    A Noninvasive Test for Vesico-Ureteric Reflux in Children

    Get PDF
    Objective To report the development and testing of a device for the noninvasive diagnosis of vesico‐ureteric reflux (VUR) which avoids the need for urethral catheterization (currently required to reliably determine the presence of VUR), and which thus avoids the anxiety of parents and patients that causes many families to refuse such evaluation. Patients and methods Fifty‐four children (49 girls and five boys, mean age 7.2 years, range 4–14) previously evaluated as having VUR volunteered to participate; no child was symptomatic at the time of the study. Refluxing units were known to be present by voiding cysto‐urethrography (within 1 year, mean 7 months) in 45 and absent in 16. The device developed acquires electronically processed acoustic signals from the child during an observed urination. The signals are then analysed ‘off‐line’ to determine the presence or absence of VUR. The initial preparation for the test included: (i) a full bladder [at least 0.80 × {(2+age) ×30 mL}] measured by ultrasonography; and (ii) localization of the pelvi‐ureteric junction by ultrasonography to accurately place the device\u27s sensors on the child\u27s back. The children were then positioned at a commode after placing the sensors; the recording was started and continued until voiding occurred. The children were tested with the recording and analysis team unaware of the presence and/or degree of VUR. The first 47 studies were single‐kidney examinations and the remaining seven included simultaneous monitoring of both kidneys. Results Sixty‐one renal units were assessed and interpretable signals were obtained from 54 (89%). There were seven episodes of ‘system failure’ when no interpretable data were obtained. One unit with no VUR had a ‘reflux’ signal; in four kidneys, spontaneous (two) and postsurgical (two) resolution of reflux was predicted by the testing and subsequently verified by cyclic radionuclide cystography. Conclusions This noninvasive diagnostic technique detected VUR in 35 of 37 refluxing units and verified no reflux in 16 of 17 units without VUR. Further refinements may allow this technology to be used in all children with suspected VUR

    Devolatilization of polypropylene particles in fluidized bed

    Get PDF
    Gasification of plastic waste is an emerging technology of particular interest to the scientific world given the production of a hydrogen-rich gas from waste material. Devolatilization is a first step thermochemical decomposition process which is crucial in determining the quality of the gas in the whole gasification process. The devolatilization of polypropylene (a key compound of plastic waste) has been investigated experimentally in a bench-scale fluidized bed reactor. Experimental tests were carried out by varying two key parameters of the process—the size of the polypropylene spheres (8–12 mm) and temperature (650–850 °C). Temperature shows the highest influence on the process. Greater molecular cracking results were more pronounced at higher temperatures, increasing the production of light hydrocarbons along with the formation of solid carbon residue and tar. The overall syngas output reduced, while the H2 content increased. Furthermore, a pseudo-first-order kinetic model was developed to describe the devolatilization process (Eapp = 11.8 kJ/mol, A1 = 0.55 s−1, ψ = 0.77)
    • 

    corecore