612 research outputs found
Laser Spectroscopy of Niobium Fission Fragments: First Use of Optical Pumping in an Ion Beam Cooler Buncher
A new method of optical pumping in an ion beam cooler buncher has been developed to selectively enhance ionic metastable state populations. The technique permits the study of elements previously inaccessible to laser spectroscopy and has been applied here to the study of Nb. Model independent mean-square charge radii and nuclear moments have been studied for Nb to cover the region of the N=50 shell closure and N≈60 sudden onset of deformation. The increase in mean-square charge radius is observed to be less than that for Y, with a substantial degree of β softness observed before and after N=60
Dynamics of Simple Balancing Models with State Dependent Switching Control
Time-delayed control in a balancing problem may be a nonsmooth function for a
variety of reasons. In this paper we study a simple model of the control of an
inverted pendulum by either a connected movable cart or an applied torque for
which the control is turned off when the pendulum is located within certain
regions of phase space. Without applying a small angle approximation for
deviations about the vertical position, we see structurally stable periodic
orbits which may be attracting or repelling. Due to the nonsmooth nature of the
control, these periodic orbits are born in various discontinuity-induced
bifurcations. Also we show that a coincidence of switching events can produce
complicated periodic and aperiodic solutions.Comment: 36 pages, 12 figure
Integrin activation - the importance of a positive feedback
Integrins mediate cell adhesion and are essential receptors for the
development and functioning of multicellular organisms. Integrin activation is
known to require both ligand and talin binding and to correlate with cluster
formation but the activation mechanism and precise roles of these processes are
not yet resolved. Here mathematical modeling, with known experimental
parameters, is used to show that the binding of a stabilizing factor, such as
talin, is alone insufficient to enable ligand-dependent integrin activation for
all observed conditions; an additional positive feedback is required.Comment: in press in Bulletin of Mathematical Biolog
Off-line studies of the laser ionization of yttrium at the IGISOL facility
A laser ion source is under development at the IGISOL facility, Jyvaskyla, in
order to address deficiencies in the ion guide technique. The key elements of
interest are those of a refractory nature, whose isotopes and isomers are
widely studied using both laser spectroscopic and high precision mass
measurement techniques. Yttrium has been the first element of choice for the
new laser ion source. In this work we present a new coupled dye-Ti:Sapphire
laser scheme and give a detailed discussion of the results obtained from laser
ionization of yttrium atoms produced in an ion guide via joule heating of a
filament. The importance of not only gas purity, but indeed the baseline vacuum
pressure in the environment outside the ion guide is discussed in light of the
fast gas phase chemistry seen in the yttrium system. A single laser shot model
is introduced and is compared to the experimental data in order to extract the
level of impurities within the gas cell.Comment: 18 pages submitted to NIM
Towards a New Standard Model for Black Hole Accretion
We briefly review recent developments in black hole accretion disk theory,
emphasizing the vital role played by magnetohydrodynamic (MHD) stresses in
transporting angular momentum. The apparent universality of accretion-related
outflow phenomena is a strong indicator that large-scale MHD torques facilitate
vertical transport of angular momentum. This leads to an enhanced overall rate
of angular momentum transport and allows accretion of matter to proceed at an
interesting rate. Furthermore, we argue that when vertical transport is
important, the radial structure of the accretion disk is modified at small
radii and this affects the disk emission spectrum. We present a simple model
demonstrating how energetic, magnetically-driven outflows modify the emergent
disk emission spectrum with respect to that predicted by standard accretion
disk theory. A comparison of the predicted spectra against observations of
quasar spectral energy distributions suggests that mass accretion rates
inferred using the standard disk model may severely underestimate their true
values.Comment: To appear in the Fifth Stromlo Symposium Proceedings special issue of
ApS
European multidisciplinary consensus statement on the use and monitoring of metal-on-metal bearings for total hip replacement and hip resurfacing.
Summary Introduction There is an ongoing debate about the optimal use of metal-on-metal (MoM) bearings in total hip replacement, since there are uncertainties about local and systemic adverse effects due to wear and corrosion of these bearings. Despite various national recommendations, efforts to achieve international harmonization of specific evidence-based recommendations for best practice are still lacking. Hypothesis An international consensus study group should be able to develop recommendations on the use and monitoring of MoM bearings, preferably at the European level, through a multidisciplinary approach, by integrating the perspectives of various stakeholders. Materials and methods Twenty-one experts representing three stakeholder groups and eight countries participated in this European consensus study, which consisted of a consensus meeting, subsequent structured discussion, and consensus voting. Results The current statement defines first of all benefits, local and systemic risks, as well as uncertain issues related to MoM bearings. Safety assessment after implantation of MoM comprises all patients. A closer follow-up is recommended for large head MoM (≥ 36 mm) and resurfacing. In these implants basic follow-up should consist of x-rays and metal ion measurement of cobalt in whole blood, performed with GF-AAS or ICP-MS. Clinical and/or radiographic abnormality as well as elevated ion levels needs additional imaging (ultrasound, CT-scan and/or MARS-MRI). Cobalt values less than 2 μg/L are probably devoid of clinical concern, the threshold value for clinical concern is expected to be within the range of 2–7 μg/L. Discussion This is the first multinational, interdisciplinary, and multiprofessional approach for developing a recommendation for the use and monitoring of MoM bearings in total hip replacement. The current recommendations are in partial agreement with previous statements regarding the extent of follow-up and imaging techniques. They however differ from previous communications regarding measurement of metal ions and especially the investigated medium, technique, and eventual threshold levels. Level of evidence Level V, expert opinion/agreement conference
System Size and Energy Dependence of Jet-Induced Hadron Pair Correlation Shapes in Cu+Cu and Au+Au Collisions at sqrt(s_NN) = 200 and 62.4 GeV
We present azimuthal angle correlations of intermediate transverse momentum
(1-4 GeV/c) hadrons from {dijets} in Cu+Cu and Au+Au collisions at sqrt(s_NN) =
62.4 and 200 GeV. The away-side dijet induced azimuthal correlation is
broadened, non-Gaussian, and peaked away from \Delta\phi=\pi in central and
semi-central collisions in all the systems. The broadening and peak location
are found to depend upon the number of participants in the collision, but not
on the collision energy or beam nuclei. These results are consistent with sound
or shock wave models, but pose challenges to Cherenkov gluon radiation models.Comment: 464 authors from 60 institutions, 6 pages, 3 figures, 2 tables.
Submitted to Physical Review Letters. Plain text data tables for the points
plotted in figures for this and previous PHENIX publications are (or will be)
publicly available at http://www.phenix.bnl.gov/papers.htm
Improved Measurement of Double Helicity Asymmetry in Inclusive Midrapidity pi^0 Production for Polarized p+p Collisions at sqrt(s)=200 GeV
We present an improved measurement of the double helicity asymmetry for pi^0
production in polarized proton-proton scattering at sqrt(s) = 200 GeV employing
the PHENIX detector at the Relativistic Heavy Ion Collider (RHIC). The
improvements to our previous measurement come from two main factors: Inclusion
of a new data set from the 2004 RHIC run with higher beam polarizations than
the earlier run and a recalibration of the beam polarization measurements,
which resulted in reduced uncertainties and increased beam polarizations. The
results are compared to a Next to Leading Order (NLO) perturbative Quantum
Chromodynamics (pQCD) calculation with a range of polarized gluon
distributions.Comment: 389 authors, 4 pages, 2 tables, 1 figure. Submitted to Phys. Rev. D,
Rapid Communications. Plain text data tables for the points plotted in
figures for this and previous PHENIX publications are (or will be) publicly
available at http://www.phenix.bnl.gov/papers.htm
- …