172 research outputs found

    Return of non-ACMG recommended incidental genetic findings to pediatric patients: Considerations and opportunities from experiences in genomic sequencing

    Get PDF
    BACKGROUND: The uptake of exome/genome sequencing has introduced unexpected testing results (incidental findings) that have become a major challenge for both testing laboratories and providers. While the American College of Medical Genetics and Genomics has outlined guidelines for laboratory management of clinically actionable secondary findings, debate remains as to whether incidental findings should be returned to patients, especially those representing pediatric populations. METHODS: The Sequencing Analysis and Diagnostic Yield working group in the Clinical Sequencing Evidence-Generating Research Consortium has collected a cohort of pediatric patients found to harbor a genomic sequencing-identified non-ACMG-recommended incidental finding. The incidental variants were not thought to be associated with the indication for testing and were disclosed to patients and families. RESULTS: In total, 23 non-ACMG-recommended incidental findings were identified in 21 pediatric patients included in the study. These findings span four different research studies/laboratories and demonstrate differences in incidental finding return rate across study sites. We summarize specific cases to highlight core considerations that surround identification and return of incidental findings (uncertainty of disease onset, disease severity, age of onset, clinical actionability, and personal utility), and suggest that interpretation of incidental findings in pediatric patients can be difficult given evolving phenotypes. Furthermore, return of incidental findings can benefit patients and providers, but do present challenges. CONCLUSIONS: While there may be considerable benefit to return of incidental genetic findings, these findings can be burdensome to providers and present risk to patients. It is important that laboratories conducting genomic testing establish internal guidelines in anticipation of detection. Moreover, cross-laboratory guidelines may aid in reducing the potential for policy heterogeneity across laboratories as it relates to incidental finding detection and return. However, future discussion is required to determine whether cohesive guidelines or policy statements are warranted

    Supporting self-management for patients with Interstitial Lung Diseases: Utility and acceptability of digital devices

    Get PDF
    INTRODUCTION: Patients diagnosed with Interstitial Lung Diseases (ILD) use devices to self-monitor their health and well-being. Little is known about the range of devices, selection, frequency and terms of use and overall utility. We sought to quantify patients' usage and experiences with home digital devices, and further evaluate their perceived utility and barriers to adaptation. METHODS: A team of expert clinicians and patient partners interested in self-management approaches designed a 48-question cross-sectional electronic survey; specifically targeted at individuals diagnosed with ILD. The survey was critically appraised by the interdisciplinary self-management group at Royal Devon University Hospitals NHS Foundation Trust during a 6-month validation process. The survey was open for participation between September 2021 and December 2022, and responses were collected anonymously. Data were analysed descriptively for quantitative aspects and through thematic analysis for qualitative input. RESULTS: 104 patients accessed the survey and 89/104 (86%) reported a diagnosis of lung fibrosis, including 46/89 (52%) idiopathic pulmonary fibrosis (IPF) with 57/89 (64%) of participants diagnosed >3 years and 59/89 (66%) female. 52/65(80%) were in the UK; 33/65 (51%) reported severe breathlessness medical research council MRC grade 3-4 and 32/65 (49%) disclosed co-morbid arthritis or joint problems. Of these, 18/83 (22%) used a hand- held spirometer, with only 6/17 (35%) advised on how to interpret the readings. Pulse oximetry devices were the most frequently used device by 35/71 (49%) and 20/64 (31%) measured their saturations more than once daily. 29/63 (46%) of respondents reported home-monitoring brought reassurance; of these, for 25/63 (40%) a feeling of control. 10/57 (18%) felt it had a negative effect, citing fluctuating readings as causing stress and 'paranoia'. The most likely help-seeking triggers were worsening breathlessness 53/65 (82%) and low oxygen saturation 43/65 (66%). Nurse specialists were the most frequent source of help 24/63 (38%). Conclusion: Patients can learn appropriate technical skills, yet perceptions of home-monitoring are variable; targeted assessment and tailored support is likely to be beneficial

    Sequential villages and settling down on the southeast U.S. coast

    Get PDF
    The adoption of more sedentary residential practices is a long process in which groups shift in size, permanence, makeup, and even location in response to the social, demographic, ecological, and subsistence pressures associated with settling down. Coastal peoples living in the Southeast U.S. are among the first to adopt more sedentary lifeways in North America as evidenced by their creation of dozens of large circular or arcing shell middens during the end of the Middle Holocene and start of the Late Holocene. Relying on material culture studies and AMS radiocarbon data refined using Bayesian statistical modeling, we investigate the sequential establishment and abandonment of three village sites built over more than 300 years and located only a few kilometers apart. These studies reveal important insights into the process of adopting more sedentary practices in the region and how local communities adapted to associated pressures

    Supporting self-management for patients with Interstitial Lung Diseases:Utility and acceptability of digital devices

    Get PDF
    INTRODUCTION: Patients diagnosed with Interstitial Lung Diseases (ILD) use devices to self-monitor their health and well-being. Little is known about the range of devices, selection, frequency and terms of use and overall utility. We sought to quantify patients' usage and experiences with home digital devices, and further evaluate their perceived utility and barriers to adaptation.METHODS: A team of expert clinicians and patient partners interested in self-management approaches designed a 48-question cross-sectional electronic survey; specifically targeted at individuals diagnosed with ILD. The survey was critically appraised by the interdisciplinary self-management group at Royal Devon University Hospitals NHS Foundation Trust during a 6-month validation process. The survey was open for participation between September 2021 and December 2022, and responses were collected anonymously. Data were analysed descriptively for quantitative aspects and through thematic analysis for qualitative input.RESULTS: 104 patients accessed the survey and 89/104 (86%) reported a diagnosis of lung fibrosis, including 46/89 (52%) idiopathic pulmonary fibrosis (IPF) with 57/89 (64%) of participants diagnosed &gt;3 years and 59/89 (66%) female. 52/65(80%) were in the UK; 33/65 (51%) reported severe breathlessness medical research council MRC grade 3-4 and 32/65 (49%) disclosed co-morbid arthritis or joint problems. Of these, 18/83 (22%) used a hand- held spirometer, with only 6/17 (35%) advised on how to interpret the readings. Pulse oximetry devices were the most frequently used device by 35/71 (49%) and 20/64 (31%) measured their saturations more than once daily. 29/63 (46%) of respondents reported home-monitoring brought reassurance; of these, for 25/63 (40%) a feeling of control. 10/57 (18%) felt it had a negative effect, citing fluctuating readings as causing stress and 'paranoia'. The most likely help-seeking triggers were worsening breathlessness 53/65 (82%) and low oxygen saturation 43/65 (66%). Nurse specialists were the most frequent source of help 24/63 (38%). Conclusion: Patients can learn appropriate technical skills, yet perceptions of home-monitoring are variable; targeted assessment and tailored support is likely to be beneficial.</p

    The Polarization of Ambient Noise on Mars

    Get PDF
    Seismic noise recorded at the surface of Mars has been monitored since February 2019, using the InSight seismometers. This noise can reach −200 dB. It is 500 times lower than on Earth at night and it increases of 30 dB during the day. We analyze its polarization as a function of time and frequency in the band 0.03–1 Hz. We use the degree of polarization to extract signals with stable polarization independent of their amplitude and type of polarization. We detect polarized signals at all frequencies and all times. Glitches correspond to linear polarized signals which are more abundant during the night. For signals with elliptical polarization, the ellipse is in the horizontal plane below 0.3 Hz. In the 0.3-1Hz high frequency band (HF) and except in the evening, the ellipse is in the vertical plane and the major axis is tilted. While polarization azimuths are different in the two frequency bands, they both vary as a function of local hour and season. They are also correlated with wind direction, particularly during the daytime. We investigate possible aseismic and seismic origins of the polarized signals. Lander or tether noise can be discarded. Pressure fluctuations transported by wind may explain part of the HF polarization but not the tilt of the ellipse. This tilt can be obtained if the source is an acoustic emission coming from high altitude at critical angle. Finally, in the evening when the wind is low, the measured polarized signals may correspond to the seismic wavefield of the Mars background noise

    Optimal functional outcome measures for assessing treatment for Dupuytren's disease: A systematic review and recommendations for future practice

    Get PDF
    This article is available through the Brunel Open Access Publishing Fund. Copyright © 2013 Ball et al.; licensee BioMed Central Ltd.Background: Dupuytren's disease of the hand is a common condition affecting the palmar fascia, resulting in progressive flexion deformities of the digits and hence limitation of hand function. The optimal treatment remains unclear as outcomes studies have used a variety of measures for assessment. Methods: A literature search was performed for all publications describing surgical treatment, percutaneous needle aponeurotomy or collagenase injection for primary or recurrent Dupuytren’s disease where outcomes had been monitored using functional measures. Results: Ninety-one studies met the inclusion criteria. Twenty-two studies reported outcomes using patient reported outcome measures (PROMs) ranging from validated questionnaires to self-reported measures for return to work and self-rated disability. The Disability of Arm, Shoulder and Hand (DASH) score was the most utilised patient-reported function measure (n=11). Patient satisfaction was reported by eighteen studies but no single method was used consistently. Range of movement was the most frequent physical measure and was reported in all 91 studies. However, the methods of measurement and reporting varied, with seventeen different techniques being used. Other physical measures included grip and pinch strength and sensibility, again with variations in measurement protocols. The mean follow-up time ranged from 2 weeks to 17 years. Conclusions: There is little consistency in the reporting of outcomes for interventions in patients with Dupuytren’s disease, making it impossible to compare the efficacy of different treatment modalities. Although there are limitations to the existing generic patient reported outcomes measures, a combination of these together with a disease-specific questionnaire, and physical measures of active and passive individual joint Range of movement (ROM), grip and sensibility using standardised protocols should be used for future outcomes studies. As Dupuytren’s disease tends to recur following treatment as well as extend to involve other areas of the hand, follow-up times should be standardised and designed to capture both short and long term outcomes

    A genome-wide association study identifies protein quantitative trait loci (pQTLs)

    Get PDF
    There is considerable evidence that human genetic variation influences gene expression. Genome-wide studies have revealed that mRNA levels are associated with genetic variation in or close to the gene coding for those mRNA transcripts - cis effects, and elsewhere in the genome - trans effects. The role of genetic variation in determining protein levels has not been systematically assessed. Using a genome-wide association approach we show that common genetic variation influences levels of clinically relevant proteins in human serum and plasma. We evaluated the role of 496,032 polymorphisms on levels of 42 proteins measured in 1200 fasting individuals from the population based InCHIANTI study. Proteins included insulin, several interleukins, adipokines, chemokines, and liver function markers that are implicated in many common diseases including metabolic, inflammatory, and infectious conditions. We identified eight Cis effects, including variants in or near the IL6R (p = 1.8×10 -57), CCL4L1 (p = 3.9×10-21), IL18 (p = 6.8×10-13), LPA (p = 4.4×10-10), GGT1 (p = 1.5×10-7), SHBG (p = 3.1×10-7), CRP (p = 6.4×10-6) and IL1RN (p = 7.3×10-6) genes, all associated with their respective protein products with effect sizes ranging from 0.19 to 0.69 standard deviations per allele. Mechanisms implicated include altered rates of cleavage of bound to unbound soluble receptor (IL6R), altered secretion rates of different sized proteins (LPA), variation in gene copy number (CCL4L1) and altered transcription (GGT1). We identified one novel trans effect that was an association between ABO blood group and tumour necrosis factor alpha (TNF-alpha) levels (p = 6.8×10-40), but this finding was not present when TNF-alpha was measured using a different assay , or in a second study, suggesting an assay-specific association. Our results show that protein levels share some of the features of the genetics of gene expression. These include the presence of strong genetic effects in cis locations. The identification of protein quantitative trait loci (pQTLs) may be a powerful complementary method of improving our understanding of disease pathways. © 2008 Melzer et al

    What are we measuring? A critique of range of motion methods currently in use for Dupuytren's disease and recommendations for practice

    Get PDF
    Background: Range of motion is the most frequently reported measure used in practice to evaluate outcomes. A goniometer is the most reliable tool to assess range of motion yet, the lack of consistency in reporting prevents comparison between studies. The aim of this study is to identify how range of motion is currently assessed and reported in Dupuytren’s disease literature. Following analysis recommendations for practice will be made to enable consistency in future studies for comparability. This paper highlights the variation in range of motion reporting in Dupuytren’s disease. Methods: A Participants, Intervention, Comparison, Outcomes and Study design format was used for the search strategy and search terms. Surgery, needle fasciotomy or collagenase injection for primary or recurrent Dupuytren’s disease in adults were included if outcomes were monitored using range of motion to record change. A literature search was performed in May 2013 using subject heading and free-text terms to also capture electronic publications ahead of print. In total 638 publications were identified and following screening 90 articles met the inclusion criteria. Data was extracted and entered onto a spreadsheet for analysis. A thematic analysis was carried out to establish any duplication, resulting in the final range of motion measures identified. Results: Range of motion measurement lacked clarity, with goniometry reportedly used in only 43 of the 90 studies, 16 stated the use of a range of motion protocol. A total of 24 different descriptors were identified describing range of motion in the 90 studies. While some studies reported active range of motion, others reported passive or were unclear. Eight of the 24 categories were identified through thematic analysis as possibly describing the same measure, ‘lack of joint extension’ and accounted for the most frequently used. Conclusions: Published studies lacked clarity in reporting range of motion, preventing data comparison and meta-analysis. Percentage change lacks context and without access to raw data, does not allow direct comparison of baseline characteristics. A clear description of what is being measured within each study was required. It is recommended that range of motion measuring and reporting for Dupuytren’s disease requires consistency to address issues that fall into 3 main categories:- Definition of terms Protocol statement Outcome reportin

    De novo variants predicting haploinsufficiency for DIP2C are associated with expressive speech delay.

    Get PDF
    The disconnected (disco)-interacting protein 2 (DIP2) gene was first identified in D. melanogaster and contains a DNA methyltransferase-associated protein 1 (DMAP1) binding domain, Acyl-CoA synthetase domain and AMP-binding sites. DIP2 regulates axonal bifurcation of the mushroom body neurons in D. melanogaster and is required for axonal regeneration in the neurons of C. elegans. The DIP2 homologues in vertebrates, Disco-interacting protein 2 homolog A (DIP2A), Disco-interacting protein 2 homolog B (DIP2B), and Disco-interacting protein 2 homolog C (DIP2C), are highly conserved and expressed widely in the central nervous system. Although there is evidence that DIP2C plays a role in cognition, reports of pathogenic variants in these genes are rare and their significance is uncertain. We present 23 individuals with heterozygous DIP2C variants, all manifesting developmental delays that primarily affect expressive language and speech articulation. Eight patients had de novo variants predicting loss-of-function in the DIP2C gene, two patients had de novo missense variants, three had paternally inherited loss of function variants and six had maternally inherited loss-of-function variants, while inheritance was unknown for four variants. Four patients had cardiac defects (hypertrophic cardiomyopathy, atrial septal defects, and bicuspid aortic valve). Minor facial anomalies were inconsistent but included a high anterior hairline with a long forehead, broad nasal tip, and ear anomalies. Brainspan analysis showed elevated DIP2C expression in the human neocortex at 10-24 weeks after conception. With the cases presented herein, we provide phenotypic and genotypic data supporting the association between loss-of-function variants in DIP2C with a neurocognitive phenotype
    corecore