503 research outputs found

    Do resting brain dynamics predict oddball evoked-potential?

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>The oddball paradigm is widely applied to the investigation of cognitive function in neuroscience and in neuropsychiatry. Whether cortical oscillation in the resting state can predict the elicited oddball event-related potential (ERP) is still not clear. This study explored the relationship between resting electroencephalography (EEG) and oddball ERPs. The regional powers of 18 electrodes across delta, theta, alpha and beta frequencies were correlated with the amplitude and latency of N1, P2, N2 and P3 components of oddball ERPs. A multivariate analysis based on partial least squares (PLS) was applied to further examine the spatial pattern revealed by multiple correlations.</p> <p>Results</p> <p>Higher synchronization in the resting state, especially at the alpha spectrum, is associated with higher neural responsiveness and faster neural propagation, as indicated by the higher amplitude change of N1/N2 and shorter latency of P2. None of the resting quantitative EEG indices predict P3 latency and amplitude. The PLS analysis confirms that the resting cortical dynamics which explains N1/N2 amplitude and P2 latency does not show regional specificity, indicating a global property of the brain.</p> <p>Conclusions</p> <p>This study differs from previous approaches by relating dynamics in the resting state to neural responsiveness in the activation state. Our analyses suggest that the neural characteristics carried by resting brain dynamics modulate the earlier/automatic stage of target detection.</p

    Reconstruction for Mandibular Implant Failure

    Get PDF
    Mandibular defects may result from tumor ablations, trauma, or radiation necrosis. Significant segmental mandibular loss or hemimandibular loss may sometimes be replaced with mandibular implants by ENT surgeons/oral surgeons/head and neck surgeons. However, this may bring about mandibular implant failure in long-term follow-up. Mandibular implant failures usually manifest as: soft tissue atrophy, mandibular implant extrusion, infection, facial nerve involvement, facial asymmetry, derangement of occlusion and mastication, orocutaneous fistula, etc. Over 30 years, the authors have treated 102 patients with mandibular implant failure. Reconstruction may involve removal of the mandibular implant and immediate replacement of the mandibular defect with a piece of vascularized bone flap, not only to compensate for bone loss but also to replace neighboring soft tissue and possible skin defects. Frequently used flaps have been vascularized iliac bone (89/102) or vascularized fibula grafts (13/102). During follow-up, iliac bone flap reconstruction has yielded more favorable results due to its ample bone bulk and adequate soft tissue coverage. Fibula flaps with osteotomies have been associated with an increasing incidence of malunion/nonunion and subsequent easy deformation

    The influence of serotonin transporter polymorphisms on cortical activity: A resting EEG study

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>The serotonin transporter gene (<it>5-HTT</it>) is a key regulator of serotonergic neurotransmission and has been linked to various psychiatric disorders. Among the genetic variants, polymorphisms in the <it>5-HTT </it>gene-linked polymorphic region (<it>5-HTTLPR</it>) and variable-number-of-tandem-repeat in the second intron (<it>5-HTTVNTR</it>) have functional consequences. However, their genetic impact on cortical oscillation remains unclear. This study examined the modulatory effects of <it>5-HTTLPR </it>(L-allele carriers vs. non-carriers) and <it>5-HTTVNTR </it>(10-repeat allele carriers vs. non-carriers) polymorphism on regional neural activity in a young female population.</p> <p>Methods</p> <p>Blood samples and resting state eyes-closed electroencephalography (EEG) signals were collected from 195 healthy women and stratified into 2 sets of comparisons of 2 groups each: L-allele carriers (<it>N </it>= 91) vs. non-carriers for <it>5-HTTLPR </it>and 10-repeat allele carriers (<it>N </it>= 25) vs. non-carriers for <it>5-HTTVNTR</it>. The mean power of 18 electrodes across theta, alpha, beta, gamma, gamma1, and gamma2 frequencies was analyzed. Between-group statistics were performed by an independent t-test, and global trends of regional power were quantified by non-parametric analyses.</p> <p>Results</p> <p>Among <it>5-HTTVNTR </it>genotypes, 10-repeat allele carriers showed significantly low regional power at gamma frequencies across the brain. We noticed a consistent global trend that carriers with low transcription efficiency of 5-HTT possessed low regional powers, regardless of frequency bands. The non-parametric analyses confirmed this observation, with <it>P </it>values of 3.071 × 10<sup>-8 </sup>and 1.459 × 10<sup>-12 </sup>for <it>5-HTTLPR </it>and <it>5-HTTVNTR</it>, respectively.</p> <p>Conclusions and Limitations</p> <p>Our analyses showed that genotypes with low 5-HTT activity are associated with less local neural synchronization during relaxation. The implication with respect to genetic vulnerability of 5-HTT across a broad range of psychiatric disorders is discussed. Given the low frequency of 10-repeat allele of <it>5-HTTVNTR </it>in our research sample, the possibility of false positive findings should also be considered.</p

    Wearable multi-channel microelectrode membranes for elucidating electrophysiological phenotypes of injured myocardium

    Get PDF
    Understanding the regenerative capacity of small vertebrate models has provided new insights into the plasticity of injured myocardium. Here, we demonstrate the application of flexible microelectrode arrays (MEAs) in elucidating electrophysiological phenotypes of zebrafish and neonatal mouse models of heart regeneration. The 4-electrode MEA membranes were designed to detect electrical signals in the aquatic environment. They were micro-fabricated to adhere to the non-planar body surface of zebrafish and neonatal mice. The acquired signals were processed to display an electrocardiogram (ECG) with high signal-to-noise-ratios, and were validated via the use of conventional micro-needle electrodes. The 4-channel MEA provided signal stability and spatial resolution, revealing the site-specific electrical injury currents such as ST-depression in response to ventricular cryo-injury. Thus, our polymer-based and wearable MEA membranes provided electrophysiological insights into long-term conduction phenotypes for small vertebral models of heart injury and regeneration with a translational implication for monitoring cardiac patients

    The Influence of Dopamine Receptor D4 Polymorphism on Resting EEG in Healthy Young Females

    Get PDF
    The polymorphism of variable number of tandem repeat (VNTR) in dopamine receptor D4 (DRD4) gene exon III has been linked to various neuro-psychiatric conditions with disinhibition/impulsivity as one of the core features. This study examined the modulatory effects of long-allele variant of DRD4 VNTR on the regional neural activity as well as inter-regional neural interactions in a young female population. Blood sample and resting state eyes-closed EEG signals were collected in 233 healthy females, stratified into two groups by polymerase chain reaction: long-allele carriers (>4- repeat) and non-carriers (<=4-repeat/<=4-repeat). The values of mean power of 18 electrodes and mutual information of 38 channel pairs across theta, alpha, and beta frequencies were analyzed. Our connectivity analysis was based on information theory, which combined Morlet wavelet transform and mutual information calculation. Between-group differences of regional power and connectivity strength were quantified by independent t-test, while between-group differences in global trends were examined by non-parametric analyses. We noticed that DRD4 VNTR long-allele was associated with decreased global connectivity strength (from non-parametric analysis), especially over bi-frontal, biparietal and right fronto-parietal and right fronto-temporal connections (from independent t-tests). The between-group differences in regional power were not robust. Our findings fit with the networks of response inhibition, providing evidence bridging DRD4 long-allele and disinhibition/impulsivity in neuropsychiatric disorders. We suggest future DRD4 studies of imaging genetics incorporate connectivity analysis to unveil its impact on cerebral network

    Association between use of non–vitamin k oral anticoagulants with and without concurrent medications and risk of major bleeding in nonvalvular atrial fibrillation

    Get PDF
    Importance:  Non–vitamin K oral anticoagulants (NOACs) are commonly prescribed with other medications that share metabolic pathways that may increase major bleeding risk. Objective:  To assess the association between use of NOACs with and without concurrent medications and risk of major bleeding in patients with nonvalvular atrial fibrillation. Design, Setting, and Participants:  Retrospective cohort study using data from the Taiwan National Health Insurance database and including 91 330 patients with nonvalvular atrial fibrillation who received at least 1 NOAC prescription of dabigatran, rivaroxaban, or apixaban from January 1, 2012, through December 31, 2016, with final follow-up on December 31, 2016. Exposures:  NOAC with or without concurrent use of atorvastatin; digoxin; verapamil; diltiazem; amiodarone; fluconazole; ketoconazole, itraconazole, voriconazole, or posaconazole; cyclosporine; erythromycin or clarithromycin; dronedarone; rifampin; or phenytoin. Main Outcomes and Measures:  Major bleeding, defined as hospitalization or emergency department visit with a primary diagnosis of intracranial hemorrhage or gastrointestinal, urogenital, or other bleeding. Adjusted incidence rate differences between person-quarters (exposure time for each person during each quarter of the calendar year) of NOAC with or without concurrent medications were estimated using Poisson regression and inverse probability of treatment weighting using the propensity score. Results:  Among 91 330 patients with nonvalvular atrial fibrillation (mean age, 74.7 years [SD, 10.8]; men, 55.8%; NOAC exposure: dabigatran, 45 347 patients; rivaroxaban, 54 006 patients; and apixaban, 12 886 patients), 4770 major bleeding events occurred during 447 037 person-quarters with NOAC prescriptions. The most common medications co-prescribed with NOACs over all person-quarters were atorvastatin (27.6%), diltiazem (22.7%), digoxin (22.5%), and amiodarone (21.1%). Concurrent use of amiodarone, fluconazole, rifampin, and phenytoin with NOACs had a significant increase in adjusted incidence rates per 1000 person-years of major bleeding than NOACs alone: 38.09 for NOAC use alone vs 52.04 for amiodarone (difference, 13.94 [99% CI, 9.76-18.13]); 102.77 for NOAC use alone vs 241.92 for fluconazole (difference, 138.46 [99% CI, 80.96-195.97]); 65.66 for NOAC use alone vs 103.14 for rifampin (difference, 36.90 [99% CI, 1.59-72.22); and 56.07 for NOAC use alone vs 108.52 for phenytoin (difference, 52.31 [99% CI, 32.18-72.44]; P &lt; .01 for all comparisons). Compared with NOAC use alone, the adjusted incidence rate for major bleeding was significantly lower for concurrent use of atorvastatin, digoxin, and erythromycin or clarithromycin and was not significantly different for concurrent use of verapamil; diltiazem; cyclosporine; ketoconazole, itraconazole, voriconazole, or posaconazole; and dronedarone. Conclusions and Relevance:  Among patients taking NOACs for nonvalvular atrial fibrillation, concurrent use of amiodarone, fluconazole, rifampin, and phenytoin compared with the use of NOACs alone, was associated with increased risk of major bleeding. Physicians prescribing NOAC medications should consider the potential risks associated with concomitant use of other drugs

    Different Renal Function Equations and Dosing of Direct Oral Anticoagulants in Atrial Fibrillation

    Get PDF
    BACKGROUND: Randomized trials of direct oral anticoagulants (DOACs) adopted the Cockcroft-Gault (CG) formula to calculate estimated glomerular filtration rate (eGFR) to determine the dosages of DOACs. OBJECTIVES: The authors aimed to investigate the agreements/disagreements of eGFRs calculated using different equations (CG, Modified Diet in Renal Disease [MDRD], and Chronic Kidney Disease Epidemiology Collaboration [CKD-EPI] formulas), and their impacts on the dosages of DOACs and clinical outcomes. METHODS: Medical data from a multicenter health care provider in Taiwan including 39,239 patients with atrial fibrillation were used. Among these patients, there were 11,185 and 2,323 patients treated with DOACs and warfarin, respectively. RESULTS: At the cutoff values of eGFR of 50 mL/min, the agreements were 78% between MDRD and CG and 81% between CKD-EPI and CG. The disagreements among the different equations were largely due to overestimations, especially for patients aged >75 years and with a body weight of <50 kg (58.8% for MDRD and 50.9% for CKD-EPI). Among patients receiving DOACs whose dosages were defined as “on label” based on MDRD or CKD-EPI, only those whose dosages were “truly on label” based on CG were associated with a lower risk of major bleeding (adjusted HR: 0.34; 95% CI: 0.26-0.45) compared to warfarin. CONCLUSIONS: The adoptions of MDRD or CKD-EPI rather than CG would result in inappropriate dosing of DOACs (mainly overdosing), which would attenuate the advantages of DOACs compared to warfarin. The CG equation should be used as the gold standard to calculate eGFRs and guide the DOAC dosages

    Pengembangan Suplemen Pembelajaran Fisika Gelombang Elektromagnetik Cahaya Sebagai Partikel Memanfaatkan Virtual Laboratorium

    Full text link
    This research has been done to make a supplement for physics learning about light electromagnetic wave as a particle using virtual laboratory. The population of this research was the second year science-students at SMA Muhammadiyah 1 Metro. This development is begun by needs analysis, then identification of resource which is the background of this developmental research. The next step is, identifying the product specification then developing products which contained a tutorial book for teacher and a work sheet for student (LKS). The material and design expert test result is that those products were approved. The external test resulted by users show that the LKS was attractive, very easy to use, and useful. It also was effective to be used as a learning resource because 80% of students reached the passing grade.Telah dilakukan penelitian untuk mengembangkan suplemen pembelajaran fisika gelombang elektromagnetik cahaya sebagai partikel dengan memanfaatkan virtual laboratorium. Populasi penelitian pengembangan ini adalah siswa kelas XI IPA di SMA Muhammadiyah 1 Metro. Pengembangan ini diawali dengan analisis kebutuhan, kemudian identifikasi sumber daya yang melatar belakangi pengembangan. Langkah selanjutnya identifikasi spesifikasi produk yang dilanjutkan dengan mengembangkan produk berupa LKS untuk siswa dan buku panduan untuk guru. Hasil uji internal oleh ahli materi dan ahli desain menyatakan produk yang dikembangkan layak digunakan sebagai media pembelajaran. Hasil uji eksternal oleh pengguna menunjukkan kualitas media pembelajaran menarik, sangat mudah digunakan, dan bermanfaat serta efektif digunakan sebagai media pembelajaran dengan presentase hasil belajar sebesar 80% siswa telah memenuhi KKM
    corecore