76 research outputs found
Field trial of three different Plasmodium vivax-detecting rapid diagnostic tests with and without evaporative cool box storage in Afghanistan
<p>Abstract</p> <p>Background</p> <p>Accurate parasitological diagnosis of malaria is essential for targeting treatment where more than one species coexist. In this study, three rapid diagnostic tests (RDTs) (AccessBio CareStart (CSPfPan), CareStart PfPv (CSPfPv) and Standard Diagnostics Bioline (SDBPfPv)) were evaluated for their ability to detect natural <it>Plasmodium vivax </it>infections in a basic clinic setting. The potential for locally made evaporative cooling boxes (ECB) to protect the tests from heat damage in high summer temperatures was also investigated.</p> <p>Methods</p> <p>Venous blood was drawn from <it>P. vivax </it>positive patients in Jalalabad, Afghanistan and tested against a panel of six RDTs. The panel comprised two of each test type; one group was stored at room temperature and the other in an ECB. RDT results were evaluated against a consensus gold standard based on two double-read reference slides and PCR. The sensitivity, specificity and a measure of global performance for each test were determined and stratified by parasitaemia level and storage condition.</p> <p>Results</p> <p>In total, 306 patients were recruited, of which 284 were positive for <it>P. vivax</it>, one for <it>Plasmodium malariae </it>and none for <it>Plasmodium falciparum</it>; 21 were negative. All three RDTs were specific for malaria. The sensitivity and global performance index for each test were as follows: CSPfPan [98.6%, 95.1%], CSPfPv [91.9%, 90.5%] and SDBPfPv [96.5%, 82.9%], respectively. CSPfPv was 16% less sensitive to a parasitaemia below 5,000/μL. Room temperature storage of SDBPfPv led to a high proportion of invalid results (17%), which reduced to 10% in the ECB. Throughout the testing period, the ECB maintained ~8°C reduction over ambient temperatures and never exceeded 30°C.</p> <p>Conclusions</p> <p>Of the three RDTs, the CSPfPan test was the most consistent and reliable, rendering it appropriate for this <it>P. vivax </it>predominant region. The CSPfPv test proved unsuitable owing to its reduced sensitivity at a parasitaemia below 5,000/μL (affecting 43% of study samples). Although the SDBPfPv device was more sensitive than the CSPfPv test, its invalid rate was unacceptably high. ECB storage reduced the proportion of invalid results for the SDBPfPv test, but surprisingly had no impact on RDT sensitivity at low parasitaemia.</p
Understanding the Relationship between Activity and Neighbourhoods (URBAN) Study: research design and methodology
<p>Abstract</p> <p>Background</p> <p>Built environment attributes are recognized as being important contributors to physical activity (PA) engagement and body size in adults and children. However, much of the existing research in this emergent public health field is hindered by methodological limitations, including: population and site homogeneity, reliance on self-report measures, aggregated measures of PA, and inadequate statistical modeling. As an integral component of multi-country collaborative research, the Understanding the Relationship between Activity and Neighbourhoods (URBAN) Study seeks to overcome these limitations by determining the strengths of association between detailed measures of the neighborhood built environment with PA levels across multiple domains and body size measures in adults and children. This article outlines the research protocol developed for the URBAN Study.</p> <p>Methods and design</p> <p>The URBAN Study is a multi-centered, stratified, cross-sectional research design, collecting data across four New Zealand cities. Within each city, 12 neighborhoods were identified and selected for investigation based on higher or lower walkability and Māori demographic attributes. Neighborhoods were selected to ensure equal representation of these characteristics. Within each selected neighborhood, 42 households are being randomly selected and an adult and child (where possible) recruited into the study. Data collection includes: objective and self-reported PA engagement, neighborhood perceptions, demographics, and body size measures. The study was designed to recruit approximately 2,000 adults and 250 children into the project. Other aspects of the study include photovoice, which is a qualitative assessment of built environment features associated with PA engagement, an audit of the neighborhood streetscape environment, and an individualized neighborhood walkability profile centered on each participant's residential address. Multilevel modeling will be used to examine the individual-level and neighborhood-level relationships with PA engagement and body size.</p> <p>Discussion</p> <p>The URBAN Study is applying a novel scientifically robust research design to provide urgently needed epidemiological information regarding the associations between the built environment and health outcomes. The findings will contribute to a larger, international initiative in which similar neighborhood selection and PA measurement procedures are utilized across eight countries. Accordingly, this study directly addresses the international priority issues of increasing PA engagement and decreasing obesity levels.</p
Impact of primary kidney disease on the effects of empagliflozin in patients with chronic kidney disease: secondary analyses of the EMPA-KIDNEY trial
Background: The EMPA KIDNEY trial showed that empagliflozin reduced the risk of the primary composite outcome of kidney disease progression or cardiovascular death in patients with chronic kidney disease mainly through slowing progression. We aimed to assess how effects of empagliflozin might differ by primary kidney disease across its broad population. Methods: EMPA-KIDNEY, a randomised, controlled, phase 3 trial, was conducted at 241 centres in eight countries (Canada, China, Germany, Italy, Japan, Malaysia, the UK, and the USA). Patients were eligible if their estimated glomerular filtration rate (eGFR) was 20 to less than 45 mL/min per 1·73 m2, or 45 to less than 90 mL/min per 1·73 m2 with a urinary albumin-to-creatinine ratio (uACR) of 200 mg/g or higher at screening. They were randomly assigned (1:1) to 10 mg oral empagliflozin once daily or matching placebo. Effects on kidney disease progression (defined as a sustained ≥40% eGFR decline from randomisation, end-stage kidney disease, a sustained eGFR below 10 mL/min per 1·73 m2, or death from kidney failure) were assessed using prespecified Cox models, and eGFR slope analyses used shared parameter models. Subgroup comparisons were performed by including relevant interaction terms in models. EMPA-KIDNEY is registered with ClinicalTrials.gov, NCT03594110. Findings: Between May 15, 2019, and April 16, 2021, 6609 participants were randomly assigned and followed up for a median of 2·0 years (IQR 1·5–2·4). Prespecified subgroupings by primary kidney disease included 2057 (31·1%) participants with diabetic kidney disease, 1669 (25·3%) with glomerular disease, 1445 (21·9%) with hypertensive or renovascular disease, and 1438 (21·8%) with other or unknown causes. Kidney disease progression occurred in 384 (11·6%) of 3304 patients in the empagliflozin group and 504 (15·2%) of 3305 patients in the placebo group (hazard ratio 0·71 [95% CI 0·62–0·81]), with no evidence that the relative effect size varied significantly by primary kidney disease (pheterogeneity=0·62). The between-group difference in chronic eGFR slopes (ie, from 2 months to final follow-up) was 1·37 mL/min per 1·73 m2 per year (95% CI 1·16–1·59), representing a 50% (42–58) reduction in the rate of chronic eGFR decline. This relative effect of empagliflozin on chronic eGFR slope was similar in analyses by different primary kidney diseases, including in explorations by type of glomerular disease and diabetes (p values for heterogeneity all >0·1). Interpretation: In a broad range of patients with chronic kidney disease at risk of progression, including a wide range of non-diabetic causes of chronic kidney disease, empagliflozin reduced risk of kidney disease progression. Relative effect sizes were broadly similar irrespective of the cause of primary kidney disease, suggesting that SGLT2 inhibitors should be part of a standard of care to minimise risk of kidney failure in chronic kidney disease. Funding: Boehringer Ingelheim, Eli Lilly, and UK Medical Research Council
Finishing the euchromatic sequence of the human genome
The sequence of the human genome encodes the genetic instructions for human physiology, as well as rich information about human evolution. In 2001, the International Human Genome Sequencing Consortium reported a draft sequence of the euchromatic portion of the human genome. Since then, the international collaboration has worked to convert this draft into a genome sequence with high accuracy and nearly complete coverage. Here, we report the result of this finishing process. The current genome sequence (Build 35) contains 2.85 billion nucleotides interrupted by only 341 gaps. It covers ∼99% of the euchromatic genome and is accurate to an error rate of ∼1 event per 100,000 bases. Many of the remaining euchromatic gaps are associated with segmental duplications and will require focused work with new methods. The near-complete sequence, the first for a vertebrate, greatly improves the precision of biological analyses of the human genome including studies of gene number, birth and death. Notably, the human enome seems to encode only 20,000-25,000 protein-coding genes. The genome sequence reported here should serve as a firm foundation for biomedical research in the decades ahead
Beyond accuracy: Epistemic flaws with statistical generalizations
What, if anything, is epistemically wrong with beliefs involving accurate statistical generalizations about demographic groups? This paper argues that there is a perfectly general, underappreciated epistemic flaw which affects both ethically charged and uncharged statistical generalizations. Though common to both, this flaw can also explain why demographic statistical generalizations give rise to the concerns they do. To identify this flaw, we need to distinguish between the accuracy and the projectability of statistical beliefs. Statistical beliefs are accompanied by an implicit representation of the statistic's modal profile. Their modal profile determines the circumstances in which they can legitimately be projected to unobserved instances. Errors in that implicit content can be compatible with the accuracy of the “bare” statistic, whilst systematically leading to downstream errors in reasoning, in a manner which reveals an epistemic flaw with an important aspect of the belief state itself
- …